China factories

Chat Now Send Email
China factory - Godson Technology Co., Ltd

Godson Technology Co., Ltd

  • China,Guangzhou ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Outdoor Emergency LED Exit Light Black 3W 6500K Battery Powered
China Outdoor Emergency LED Exit Light Black 3W 6500K Battery Powered

  1. China Outdoor Emergency LED Exit Light Black 3W 6500K Battery Powered
  2. China Outdoor Emergency LED Exit Light Black 3W 6500K Battery Powered
  3. China Outdoor Emergency LED Exit Light Black 3W 6500K Battery Powered
  4. China Outdoor Emergency LED Exit Light Black 3W 6500K Battery Powered
  5. China Outdoor Emergency LED Exit Light Black 3W 6500K Battery Powered

Outdoor Emergency LED Exit Light Black 3W 6500K Battery Powered

  1. MOQ: 50PCS
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Model GS-CU01
Power 3W
Duration Time 1.5 Hours
Voltage AC85-265V-50/60Hz
Lanp Luminous Flux 300Lm
Operating Temperature 0-40 ℃
Brand Name Godson or OEM
Model Number Emergency LED Exit Light GS-CU01
Place of Origin Guangdong, China (Mainland)

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Model GS-CU01
Power 3W Duration Time 1.5 Hours
Voltage AC85-265V-50/60Hz Lanp Luminous Flux 300Lm
Operating Temperature 0-40 ℃ Brand Name Godson or OEM
Model Number Emergency LED Exit Light GS-CU01 Place of Origin Guangdong, China (Mainland)
High Light Outdoor Emergency LED Exit LightEmergency LED Exit Light 3WEmergency LED Exit Light 6500K


Outdoor Emergency LED Exit Light White 3W 6500K Battery Powered
Technical Specifications
 

Model
GS-CU01
Size
350*25*145mm
Power
3W
Voltage
AC85-265V-50/60Hz
Emergency time
≥ 1.5h
Battery
lithium battery
/Ni-CD/Ni-MH
CCT
6500 K
Lanp Luminous Flux
300Lm
Operating Temperature 0-40

 
 

Features
- Wall mounting
- battery, replaceable
-1.5 hours emergency duration

 
 

Materials
-Base:ABS/PC
 

Dimensions
 


Monthly Testing
 
This only requires a short test to check that everything is working properly. Use the test key to ensure that all emergency lights are on when the mains power is off and check the enclosures to ensure they are clean and show no signs of damage. Once mains power is restored, check that they are fully charged again.
Also most emergency lights or exit signs have a small "test" button somewhere in the housing. You can press and hold this button for thirty seconds to test the bulb and battery. This method works fine if you have a small number of devices that can be easily accessed. The light should come on and stay at the same brightness level for a full 30 seconds. If the lights dim immediately, or if some bulbs do not work, then you should contact us to replace the bulbs or batteries in the fixture.
 
Why thirty seconds?
 
Many defective batteries only hold enough charge to fully light the bulb for a few seconds, but they lose power quickly. If you don't test for 30 seconds, you may find lights that work every month only to find that they go out within seconds of when you really need them. By testing the lights for at least 30 seconds, you can ensure that the batteries have more than just this type of "surface charge".
 
Annual Testing
 
Locate the circuit breaker or fuse that supplies power to the emergency light or exit sign. (If they are not properly marked, you may need to contact an electrician.) Turn off the circuit breakers and observe the lights to determine if they are working properly during the three-hour test period.
 
Why three hours?
 
It is important to test emergency lights annually for their full rated duration. Emergency lights should provide a minimum of 3 hours of illumination (which is usually the case), so they need to be tested for the full 3 hours to ensure they are still working at the end of the test.


 

What Are Maintained Emergency Lights Types?
 
Maintained lights are illuminated all the time (24/7) for safety. This means that they switch to a battery-powered emergency output. Even if the power fails, the light will remain on.
This safety light is most commonly an LED, and it should illuminate an exit path and should be easily seen should there be a fire to provide the occupant's safety.
An emergency lighting system in continuous use is called a maintained system. These lighting systems typically remain illuminated 24/7, and each light has dual purposes - one as a regular emergency lamp and another as an emergency light. Maintained lighting systems are often used as escape route lighting and found in buildings such as hospitals or police stations.
 
 
What Are Non-Maintained Emergency Lights?
 
Non-maintained lights usually are not illuminated and will only turn on (illuminate) when the power fails. - The batteries are constantly being charged while ever there is power to the fitting. Power can be cut to a building in the event of a fire. Fire safety security alarm systems can control signs and luminaires. These fire safety systems require appropriate training, building signs and appropriate lighting.
 
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Ecer Certification:

    Verified Supplier

  Godson Technology Co., Ltd. is a globally trusted supplier and manufacturer of emergency lighting battery, emergency lighting products, E-bike battery and power tool battery, whose batteries range covers Ni-Cd, Ni-MH, LiFePO4, Lead Acid, Lion-polymer and other relevant lithium batteries....   Godson Technology Co., Ltd. is a globally trusted supplier and manufacturer of emergency lighting battery, emergency lighting products, E-bike battery and power tool battery, whose batteries range covers Ni-Cd, Ni-MH, LiFePO4, Lead Acid, Lion-polymer and other relevant lithium batteries....

+ Read More

Get in touch with us

  • Reach Us
  • Godson Technology Co., Ltd
  • Unit 103B (Main Building), Building 4, No. 29 North Pier Road, Huang Pu Village, Haizhu District, Guangzhou, Guangdong, China ,510330
  • https://www.emergencylight-batteries.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement