China factories

China factory - Godson Technology Co., Ltd

Godson Technology Co., Ltd

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Non Maintained Emergency LED Exit Light Downlight 3W 300Lm
China Non Maintained Emergency LED Exit Light Downlight 3W 300Lm

  1. China Non Maintained Emergency LED Exit Light Downlight 3W 300Lm
  2. China Non Maintained Emergency LED Exit Light Downlight 3W 300Lm
  3. China Non Maintained Emergency LED Exit Light Downlight 3W 300Lm
  4. China Non Maintained Emergency LED Exit Light Downlight 3W 300Lm

Non Maintained Emergency LED Exit Light Downlight 3W 300Lm

  1. MOQ: 50PCS
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Mains Supply AC85-265V-50/60Hz
Power 3 W
Duration Time 3 Hours
Recharge Period 16 Hours
Battery Size & Type lithium battery /Ni-CD/Ni-MH
Brand Name Godson or OEM
Model Number LED Exit Light GS-068
Place of Origin Guangdong, China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Mains Supply AC85-265V-50/60Hz
Power 3 W Duration Time 3 Hours
Recharge Period 16 Hours Battery Size & Type lithium battery /Ni-CD/Ni-MH
Brand Name Godson or OEM Model Number LED Exit Light GS-068
Place of Origin Guangdong, China (Mainland)
High Light Emergency LED Exit Light 3W300Lm Emergency LED Exit Light


Non Maintained Emergency LED Downlight White 2.5W 130mm EGSMD40/EGSMD50/EGSMD63


Technical Specifications

 

Mains Supply
AC85-265V-50/60Hz
Power 3W
Duration Time 3 Hours
Recharge Period 16 Hours
Battery Size & Type
lithium battery
/Ni-CD/Ni-MH
LED Power 3W
CCT 6500k
Luminous Flux 300Lm
Size
240*20*190mm
Protection Class Class
Operating Temperature 0-40

 

 

Features

 

- Wall or ceiling mounting
- battery, replaceable
-3 hours emergency duration

 

 

Materials
 
-Base:ABS/PC
 

 

What Are Maintained Emergency Lights Types?

 

Maintained lights are illuminated all the time (24/7) for safety. This means that they switch to a battery-powered emergency output. Even if the power fails, the light will remain on.

This safety light is most commonly an LED, and it should illuminate an exit path and should be easily seen should there be a fire to provide the occupant's safety.

An emergency lighting system in continuous use is called a maintained system. These lighting systems typically remain illuminated 24/7, and each light has dual purposes - one as a regular emergency lamp and another as an emergency light. Maintained lighting systems are often used as escape route lighting and found in buildings such as hospitals or police stations.

 

 

What Are Non-Maintained Emergency Lights?

 

Non-maintained lights usually are not illuminated and will only turn on (illuminate) when the power fails. - The batteries are constantly being charged while ever there is power to the fitting. Power can be cut to a building in the event of a fire. Fire safety security alarm systems can control signs and luminaires. These fire safety systems require appropriate training, building signs and appropriate lighting.

 

 

Emergency lighting

 

While the frequency of testing emergency equipment will be determined by the individual emergency lighting system, as a general guideline, most systems require a monthly inspection followed by a full duration test once a year.

 

 

Monthly Testing
 

This only requires a short test to check that everything is working properly. Use the test key to ensure that all emergency lights are on when the mains power is off and check the enclosures to ensure they are clean and show no signs of damage. Once mains power is restored, check that they are fully charged again.

Also most emergency lights or exit signs have a small "test" button somewhere in the housing. You can press and hold this button for thirty seconds to test the bulb and battery. This method works fine if you have a small number of devices that can be easily accessed. The light should come on and stay at the same brightness level for a full 30 seconds. If the lights dim immediately, or if some bulbs do not work, then you should contact us to replace the bulbs or batteries in the fixture.


 

Why thirty seconds?
 

Many defective batteries only hold enough charge to fully light the bulb for a few seconds, but they lose power quickly. If you don't test for 30 seconds, you may find lights that work every month only to find that they go out within seconds of when you really need them. By testing the lights for at least 30 seconds, you can ensure that the batteries have more than just this type of "surface charge".

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Ecer Certification:

    Verified Supplier

  Godson Technology Co., Ltd. is a globally trusted supplier and manufacturer of emergency lighting battery, emergency lighting products, E-bike battery and power tool battery, whose batteries range covers Ni-Cd, Ni-MH, LiFePO4, Lead Acid, Lion-polymer and other relevant lithium batteries....   Godson Technology Co., Ltd. is a globally trusted supplier and manufacturer of emergency lighting battery, emergency lighting products, E-bike battery and power tool battery, whose batteries range covers Ni-Cd, Ni-MH, LiFePO4, Lead Acid, Lion-polymer and other relevant lithium batteries....

+ Read More

Get in touch with us

  • Reach Us
  • Godson Technology Co., Ltd
  • Unit 103B (Main Building), Building 4, No. 29 North Pier Road, Huang Pu Village, Haizhu District, Guangzhou, Guangdong, China ,510330
  • https://www.emergencylight-batteries.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement