China factories

Chat Now Send Email
China factory - HK FY-MED TRADING CO., LIMITED

HK FY-MED TRADING CO., LIMITED

  • China ,Hongkong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Optional Flexible Endoscope Parts Endoscopy Bending Sections Metal
China Optional Flexible Endoscope Parts Endoscopy Bending Sections Metal

  1. China Optional Flexible Endoscope Parts Endoscopy Bending Sections Metal
  2. China Optional Flexible Endoscope Parts Endoscopy Bending Sections Metal
  3. China Optional Flexible Endoscope Parts Endoscopy Bending Sections Metal

Optional Flexible Endoscope Parts Endoscopy Bending Sections Metal

  1. MOQ: 1 piece
  2. Price: Negotiable
  3. Get Latest Price
Connector Type variable
Length Varies
Type Medical Parts
Weight Varies
Accessories optional
Working Channel variable
Name Flexible Scope Parts
Packaging Details standard packaging
Delivery Time 5-7 day
Payment Terms T/T etc.
Diameter Varias
Colour Varies
Material Plastic and Metal

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Connector Type variable Length Varies
Type Medical Parts Weight Varies
Accessories optional Working Channel variable
Name Flexible Scope Parts Packaging Details standard packaging
Delivery Time 5-7 day Payment Terms T/T etc.
Diameter Varias Colour Varies
Material Plastic and Metal
High Light Flexible endoscope bending sections ,Metal endoscope bending parts ,Optional endoscopy bending components
Endoscopy Bending Sections For Varias Endoscope Flexible Endoscope Parts
ModelODthincknessinner borelengthmaterial
GIF-XQ240¢8.50.3¢5.068S304
GIF-Q180¢8.50.3¢5.068S304
GIF-Q145¢9.00.3¢5.472S304
PCF-P240AL¢9.30.3¢5.399S304
PCF-160AL¢9.70.3¢5.999S304
PCF-Q180AL¢9.70.33¢5.999S304
PCF-Q260AL¢9.70.3¢5.998S304
CF-240L¢10.90.35¢6.7111S304
CF-Q160AL¢11.60.35¢7.4113S304
CF-Q180AL¢11.60.4¢7.4113S304
CF-H180AL¢11.60.4¢7.4112S304
CF-H260DL¢12.10.35¢7.7112S304
TJF-260¢11.00.3¢6.454S304
GIF-H260¢8.80.3¢5.172S304
GIF-Q160¢8.80.3¢4.673S304
TJF-160¢11.00.3¢6.454S304
CF-Q160I¢11.60.4¢7.4113S304
GIF-160¢8.50.3¢4.868S304
GIF-Q260¢8.70.3¢8.268S304
PCF-140L¢9.70.3¢5.998S304
GIF-1T240¢10.10.3¢6.284S304
CF-240DL¢10.90.35¢6.7111S304
CF-Q260DL¢10.90.35¢6.7111S304
TJF-240¢11.00.3¢6.454S304
GIF-V70¢8.50.3¢5.073S304
CF-HQ190¢11.60.4¢7.3109S304
CF-V70I¢11.60.4¢7.3109S304
PCF-Q260JI¢9.70.3¢5.992S304
PCF-Q260AZI     
GIF-140¢8.80.3¢5.572S304
GIF-Q140¢9.30.3¢5.675S304
PCF-H180AL¢10.20.3¢5.999S304
PCF-240L¢9.70.3¢5.999S304
CF-Q260AI¢10.90.35¢6.5107S304
GIF-H180¢9.10.3¢5.675S304
GIF-Q240¢8.80.3¢5.174S304
CHF-T20¢5.50.15¢3.838S304
CHF-P60¢4.60.15¢3.137.8S304
CF-140I¢11.60.3¢7.4108S304
GIF-Q150¢8.50.3¢5.068S304
GIF-Q260J¢9.50.3¢5.971S304
GIF-XTQ160¢11.80.3¢889S304
GIF-2T160¢11.60.3¢7.689S304
TJF-Q180V¢11.00.3¢7.054S304
LF-GP¢3.70.12¢2.633S304
11272CU1¢4.60.15¢3.150.4S304
CF-H190L¢11.60.4¢7.3109S304
PCF-H190L¢10.250.3¢5.698S304
CF-HQ190¢11.80.4/46.5S304
GIF-H180J¢9.50.3¢6.077S304
GIF-H185/190¢8.90.35.166.2S304
PCF-PH190L¢9.10.35.596.7S304
PCF-PH190L¢9.50.3/58.2S304
PCF-H190L¢10.250.3¢5.698S304
112782.55*2.150.1¢1.368S304
GIF-N180¢4.80.15¢3.373S304
BF-Q180¢4.80.15¢3.348.5S304
URF-P5¢2.50.1¢1.8565S304
URF-V¢3.150.1¢2.165S304
CYF-5¢4.80.15¢3.660S304
CF-HQ190¢11.80.4/46.5S304
GIF-1TQ160¢10.00.3¢6.485.5S304
GIF-2TH180¢11.30.3¢7.485.4S304
CYF-V2¢5.00.15¢3.659.5S304
LTF-240¢6.50.3¢4.353.3S304
GIF-XP180N¢5.20.15¢3.172.7S304
 ¢2.80.1¢1.918.8S304
LF-DP¢2.80.1¢1.923.8S304
ENF-GP/P4¢3.30.12¢2.225.3S304
GIF-HQ290¢9.50.3¢676.3S304
GIF-H290¢8.60.25¢4.963.8S304
CF-HQ290¢11.60.4¢7.3107.6S304
7326.071¢3.00.1¢2.167.7S304
7325.071¢2.60.1¢1.7568S304
CYF-VH¢5.10.15¢3.753.5S304
PCF-H190DL¢10.90.3¢6.4101.5S304
PCF-H190DL¢11.00.3/55.2S304
11101RP2¢3.20.12¢2.132S304
11101VN¢3.20.12¢2.135S304
GIF-HQ190¢9.50.3¢674.5S304
CHF-V¢4.60.15¢3.242S304
ENF-VT2¢4.60.15¢3.237S304
ENF-V2¢3.00.1¢2.126.6S304
BF-260¢4.60.15¢3.242S304
BF-P180¢4.60.15¢3.246.3S304
11292ED1¢4.60.15¢3.150.4S304
BF-H190¢4.80.15¢3.353.5S304
TJF-145 
GIF-Q240X¢8.90.3¢5.372.5S304
GIF-H170¢8.90.25¢5.166S304
GIF-XP260N¢5.20.15¢3.172.7S304
GIF-XP190N¢5.50.15¢3.070.1S304
ENF-XP¢1.860.08¢1.019.7S304
7223.001¢3.20.12¢2.227.3S304
JF-260V¢11.00.3¢6.454S304
BF-P60¢4.60.15¢3.142.8S304
ENF-T3¢4.80.15¢3.132.8S304
BF-1T180¢5.60.15¢4.054.7S304
BF-Q190¢4.650.15¢3.1550.6S304
CF-H290I¢11.00.4¢6.2102.4 
TJF-160R¢11.00.3¢6.454S304
BF-1TH190¢6.00.15¢3.855.7 
BF-1T260¢5.650.15¢4.050.9 
TJF-140F¢11.00.3¢6.455.1 
11272VN     
BF-P240¢4.650.15¢3.345.8 
FG-29W¢9.10.25¢5.666.2 

The bending section is composed of a series of oddly-shaped metal rings

The bending section is composed of a series of oddly-shaped metal rings, each one connected to the ring on either side of it via a freely moving joint. These joints are constructed using a series of pivot pins, each one displaced from its neighbors by 90 degrees.

The direction of the curl is controlled by four angulation wires that run the length of the insertion tube.

One set of pivots allows the bending section to curl in the up-and-down direction. A second set allows the bending section to curl in the right-and-left direction. Together, they enable the bending section to curl in any direction. The direction of the curl is controlled by four angulation wires that run the length of the insertion tube. These four wires are firmly attached to the tip of the bending section at the 3 o’clock, 6 o’clock, 9 o’clock, and 12 o’clock positions. Pulling on the wire attached at the 12 o’clock position causes the bending section to curl in the up direction and achieves what endoscopists refer to as “up tip deflection.” Pulling on the wire attached at the 3 o’clock position causes right tip deflection. Pulling the other two wires causes down and left deflection. The endoscopist is able to pull on each of these wires in turn by rotating either the up-and-down or right-and-left angulation knobs. Rotating the up-and-down and right-and-left knobs together produces a combined tip movement (e.g., upward and to the right) and allows the endoscopist to sweep the tip of the endoscope in any direction.

Product Overview

A bending section is the articulated metal segment at the distal end of a flexible endoscope: a stack of stainless steel rings that carries the angulation wires, protects the internal optics and channel, and takes the mechanical load of every up/down and left/right movement. When the original bending section is crushed, kinked or its rings separate, the scope will not hold angulation and the rubber boot will leak. Replacing the section — rather than the whole insertion tube assembly — is a standard repair that returns a scope to service for a fraction of its replacement cost.

Stocked Configurations
ModelOD (mm)Thickness (mm)Inner bore (mm)Length (mm)Material
GIF-XQ240φ8.50.3φ5.068S304
GIF-Q180φ8.50.3φ5.068S304
GIF-Q145φ9.00.3φ5.472S304
PCF-P240ALφ9.30.3φ5.399S304
PCF-160ALφ9.70.3φ5.999S304
PCF-Q180ALφ9.70.33φ5.999S304
PCF-Q260ALφ9.70.3φ5.998S304
CF-240Lφ10.90.35φ6.7111S304
CF-Q160ALφ11.60.35φ7.4113S304
CF-Q180ALφ11.60.4φ7.4113S304
CF-H180ALφ11.6 φ7.4 S304

Other diameters, lengths and connector types can be supplied on request; the working channel and connector geometry are variable across the range.

Why the Dimensions Matter
Outer diameter must match the scope's distal end so that the boot and the optics housing seat correctly.
Wall thickness sets both the crush resistance and the bend radius — a thicker wall resists kinking but is stiffer.
Inner bore must clear the channel and the optics bundle; any interference will pinch the channel on angulation.
Length determines the articulation span; a section that is too long will not reach the required angulation angle.
S304 stainless steel is the standard material: corrosion resistant and dimensionally stable through repeated sterilisation.
Installation Guidance
Measure the original section before ordering: OD, bore, length and ring count.
Route the angulation wires through the new section without twisting; crossed wires cause uneven deflection.
Fit a new rubber boot at the same time — reusing an old boot is the most common reason a fresh repair leaks within weeks.
After reassembly, cycle the angulation through its full range and leak test before returning the scope to service.
Ordering Notes
Can you supply a section for a model not listed?
Yes — send us the scope model and the measured dimensions and we will confirm availability.
Do you supply other flexible scope parts?
Yes — insertion tubes, light guides, connectors, valves and optics are also available.
Delivery?
One piece minimum, dispatch normally within 5-7 working days, freight quoted for your destination.
Product Specification Summary
ParameterValue
Accessoriesoptional
Connector Typevariable
Working Channelvariable
NameFlexible Scope Parts
LengthVaries
TypeMedical Parts
WeightVaries
DiameterVarias
ColourVaries
MaterialPlastic and Metal

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company,Seller

  • Year Established:

    2017

  • Total Annual:

    5000000-10000000

  • Employee Number:

    50~60

  • Ecer Certification:

    Verified Supplier

We're FY MED TRADING CO., LIMITED.     HK FY-MED, advocating the concept of environmental protection and saving, aims to improve the quality of endoscopic products and the service life of the products, thus helping customers to save costs. In addition, we are committed to de... We're FY MED TRADING CO., LIMITED.     HK FY-MED, advocating the concept of environmental protection and saving, aims to improve the quality of endoscopic products and the service life of the products, thus helping customers to save costs. In addition, we are committed to de...

+ Read More

Get in touch with us

  • Reach Us
  • HK FY-MED TRADING CO., LIMITED
  • Rd Central HongKong
  • https://www.endoscopesmedical.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement