Packaging Details | Neutral carton |
Delivery Time | 5-8 working days |
Payment Terms | Online order, T/T |
Supply Ability | 100 Unit/Week |
Name | Multi Gas Detector |
Detect Gas | H2S CO O2 EX, OEM |
Unit | PPM, %LEL, %VOL, mg/m³ |
Detection Principle | Electrochemical, Infrared, PID etc.. |
Range | 0-100%LEL/PPM/%VOL |
Brand Name | JUGE |
Model Number | None |
Certification | IOS9001, CE |
Place of Origin | Nanjing, China |
View Detail Information
Explore similar products
Wall Mounted Fixed Single Gas Leak Detector Ex H2S VOC CO CO2 O C6H6 C7H8 LEL
Pumping Portable Gas Detector Device OEM Multi Gas Ammonia CO2 Ex O2 H2S CO
24V Industrial Temperature And Humidity Transmitter High Accuracy
Bag Filter Leak Detector Insertion Type Dust Analyzer Durable Electrode Design
Product Specification
Packaging Details | Neutral carton | Delivery Time | 5-8 working days |
Payment Terms | Online order, T/T | Supply Ability | 100 Unit/Week |
Name | Multi Gas Detector | Detect Gas | H2S CO O2 EX, OEM |
Unit | PPM, %LEL, %VOL, mg/m³ | Detection Principle | Electrochemical, Infrared, PID etc.. |
Range | 0-100%LEL/PPM/%VOL | Brand Name | JUGE |
Model Number | None | Certification | IOS9001, CE |
Place of Origin | Nanjing, China | ||
High Light | Fixed Multi Gas Leak Detector ,Explosion Proof Multi Gas Leak Detector |
Equipped with original imported intelligent gas sensors, this is a high-performance intelligent detection instrument capable of continuous online monitoring of multiple gases. The detector features an integral explosion-proof structure with high sensitivity and precision. Real-time gas concentration data can be displayed on a computer through a gas alarm controller and monitoring software. Additionally, optional wireless modules enable real-time transmission of monitoring data and alarm statuses to safety control centers. It is widely applicable across industries such as petroleum/petrochemicals, metallurgy, environmental protection, gas, fire safety, municipal services, chemical engineering, shipbuilding, power generation, process control, wastewater treatment, and emergency rescue monitoring.
>>Main technical parameters
Detection Principle | Electrochemical principle, Infrared principle, Catalytic combustion principle |
Measuring Range | H₂S: 0-100 ppm; CO: 0-1000 ppm; O₂: 0-25% VOL; Ex: 0-100% LEL (other gases customizable) |
Resolution |
0.01, 0.1, 1 |
Sampling Method |
Free diffusion type – Online continuous detection with free diffusion method. |
Installation Method |
Wall-mounted; Pipeline-mounted (clamp-on or insertion type, with external threads) |
Indication Error | ≤±1% F.S |
Repeatability | ≤±1% (F.S/year) |
Zero Drift | ≤±1% (F.S/year) |
Response Time |
≤20 seconds (T90) (higher requirements depend on sensor performance) |
Recovery Time |
≤10 seconds (T90) (higher requirements depend on sensor performance) |
Power Supply | 12-30 VDC |
Power Consumption |
≤2.5 W (at DC24V) |
Environmental Pressure |
80 kPa ~ 120 kPa |
Environmental Temperature |
-20°C ~ +60°C (typical); -40°C ~ +80°C (extreme) |
Environmental Humidity |
10%~95% RH (non-condensing) |
Main Material |
ADC12 aluminum alloy housing with Teflon coating (wear-resistant and corrosion-resistant) |
Output Signal |
Three-wire 4-20 mA current signal output (compatible with alarm controllers) |
Signal Transmission |
Shielded three-core (or four-core) cable; maximum transmission distance: 1000-2000 meters |
Alarm Method |
Audible and visual alarm (optional, alarm sound <90 dB) |
Direct Reading |
Measured value, max/min values |
Data Download |
RS485 serial port for data export |
Calibration |
2-4 point calibration; customizable calibration values |
Explosion-proof Electrical |
① NPT 3/4 internal thread (optional: 1/2 NPT, G3/4, G1/2); ② Explosion-proof cable gland (optional, certified) |
Explosion-proof Mark |
Ex d II CT6 Gb |
Protection Level |
IP66 |
Dimensions |
180 mm (H) × 140 mm (W) × 92 mm (D) |
Weight |
Approx. 1.6 kg (aluminum alloy housing) |
Compliance Standards |
GB15322.1-2003, GB3836.1-2010, GB3836.2-2010 |
Quality Assurance |
1-year warranty; free repair during warranty period |
>>List of Commonly Detected Gas Types
NO |
Detection |
Range |
Accuracy |
T90 Response time |
Resolution |
Alarm set point (low/high) |
1 |
PH3 |
0 – 5 ppm |
±5% (F.S) |
≤ 25 s |
0.01 ppm |
0.3 ppm/5 ppm |
2 |
O2 |
0-30%Vol |
±5% (F.S) |
≤ 15 s |
0.10% Vol |
18.0%Vol/23.0%Vol |
3 |
EX |
0-100% LEL |
±5% (F.S) |
≤ 15 s |
1% LEL |
25.0%/50.0% LEL |
4 |
CO |
0 - 2000 ppm |
±5% (F.S) |
≤ 25 s |
1 ppm |
50 ppm/100 ppm |
5 |
H2S |
0 -100 ppm |
±5% (F.S) |
≤ 30 s |
1 ppm |
10 ppm/20 ppm |
6 |
SO2 |
0 - 100 ppm |
±5% (F.S) |
≤ 30 s |
0.1 ppm |
2 ppm /10 ppm |
7 |
CI2 |
0 - 20 ppm |
±5% (F.S) |
≤ 30 s |
0.1 ppm |
1 ppm /10 ppm |
8 |
NH3 |
0 – 200 ppm |
±5% (F.S) |
≤ 50 s |
1 ppm |
25 ppm /50 ppm |
9 |
NO2 |
0 - 20 ppm |
±5% (F.S) |
≤ 25 s |
0.1 ppm |
3 ppm/10 ppm |
10 |
NO |
0 - 250 ppm |
±5% (F.S) |
≤ 60 s |
1 ppm |
25 ppm/50 ppm |
11 |
H2 |
0 - 1000 ppm |
±5% (F.S) |
≤ 60 s |
1 ppm |
50 ppm /100 ppm |
12 |
HCN |
0 - 50 ppm |
±5% (F.S) |
≤ 200 s |
0.1 ppm |
10 ppm /20 ppm |
13 |
HCL |
0 - 20 ppm |
±5% (F.S) |
≤ 60 s |
0.1 ppm |
5 ppm /10 ppm |
14 |
CH4 |
0 - 5% Vol |
±5% (F.S) |
≤ 60 s |
0.1% Vol |
customized |
15 |
CO2 |
0 - 5% Vol (0-5000ppm) |
±5% (F.S) |
≤ 60 s |
0.01% Vol (1 ppm) |
customized |
16 |
PID(VOCs) |
1-1999 ppm |
±5% (F.S) |
≤ 20 s |
0.1 ppm |
customized |
17 |
C3H8 |
0 - 5%Vol |
±5% (F.S) |
≤ 60s |
0.01% Vol |
customize |
18 |
O3 |
0 – 5 ppm |
±5% (F.S) |
≤ 30s |
0.02 ppm |
1ppm/2 ppm |
19 |
SF6 |
0 – 1000 ppm |
±5% (F.S) |
≤ 60s |
0.2ppm |
25ppm/50 ppm |
20 |
HF |
0 – 10 ppm |
±5% (F.S) |
≤ 60s |
0.1ppm |
3ppm/10 ppm |
Remark: Customized alarm setting points and detection ranges are also available.
Company Details
Business Type:
Manufacturer
Year Established:
2015
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is... Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is...