Name Multi Gas Detector
Detect Gas H2S CO O2 EX, OEM
Unit PPM, %LEL, %VOL, mg/m³
‌Detection Principle‌ Electrochemical, Infrared, PID etc..
Range 0-100%LEL/PPM/%VOL
Brand Name JUGE
Model Number None
Certification IOS9001, CE
Place of Origin Nanjing, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details Neutral carton Delivery Time 5-8 working days
Payment Terms Online order, T/T Supply Ability 100 Unit/Week
Name Multi Gas Detector Detect Gas H2S CO O2 EX, OEM
Unit PPM, %LEL, %VOL, mg/m³ ‌Detection Principle‌ Electrochemical, Infrared, PID etc..
Range 0-100%LEL/PPM/%VOL Brand Name JUGE
Model Number None Certification IOS9001, CE
Place of Origin Nanjing, China
High Light Fixed Multi Gas Leak DetectorExplosion Proof Multi Gas Leak Detector
Fixed Multi Gas Composite Gas H2S CO O2 Ex Leak Detector
 
>>Overview

Equipped with original imported intelligent gas sensors, this is a high-performance intelligent detection instrument capable of continuous online monitoring of multiple gases. The detector features an integral explosion-proof structure with high sensitivity and precision. Real-time gas concentration data can be displayed on a computer through a gas alarm controller and monitoring software. Additionally, optional wireless modules enable real-time transmission of monitoring data and alarm statuses to safety control centers. It is widely applicable across industries such as petroleum/petrochemicals, metallurgy, environmental protection, gas, fire safety, municipal services, chemical engineering, shipbuilding, power generation, process control, wastewater treatment, and emergency rescue monitoring.

 
>>Features
◆ Original imported high-performance sensors with high measurement accuracy, excellent repeatability, and long service life.
◆ 16-bit AD chip and 4-layer PCB design ensure enhanced weak signal processing and superior anti-interference capabilities.
◆ Dashboard-style display interface with clear, elegant readings and user-friendly design details.
◆ Multiple unit options: mg/m³, ppm, VOL, and LEL.
◆ Embedded 32-bit low-power processor paired with proprietary signal processing algorithms for fast response speed and high stability.
◆ Auto-protection against high-concentration gas impact, factory reset function, and misoperation prevention.
◆ Built-in infrared remote control for easy operation without opening the housing.
◆ Configurable outputs: three-wire 4–20mA, RS485 signal, and relay output.
◆ Dual cable entry ports for convenient on-site installation.
◆ Robust mechanical design: Gas chamber made of high-grade aluminum alloy profile ensures wear-resistant, corrosion-resistant performance in harsh industrial environments. Scientifically optimized gas chamber design guarantees real-time monitoring accuracy.
◆ Explosion-proof certification: Exd II CT6, certified by the National Explosion-Proof Electrical Product Testing Center.

 

 

>>Main technical parameters

Detection Principle Electrochemical principle, Infrared principle, Catalytic combustion principle
Measuring Range H₂S: 0-100 ppm; CO: 0-1000 ppm; O₂: 0-25% VOL; Ex: 0-100% LEL (other gases customizable)
Resolution

0.01, 0.1, 1

Sampling Method

Free diffusion type – Online continuous detection with free diffusion method.

Installation Method

Wall-mounted; Pipeline-mounted (clamp-on or insertion type, with external threads)

Indication Error ≤±1% F.S
Repeatability ±1% (F.S/year)
Zero Drift ±1% (F.S/year)
Response Time

20 seconds (T90) (higher requirements depend on sensor performance)

Recovery Time

10 seconds (T90) (higher requirements depend on sensor performance)

Power Supply 12-30 VDC
Power Consumption

2.5 W (at DC24V)

Environmental Pressure

80 kPa ~ 120 kPa

Environmental Temperature

-20°C ~ +60°C (typical); -40°C ~ +80°C (extreme)

Environmental Humidity

10%~95% RH (non-condensing)

Main Material

ADC12 aluminum alloy housing with Teflon coating (wear-resistant and corrosion-resistant)

Output Signal

Three-wire 4-20 mA current signal output (compatible with alarm controllers)

Signal Transmission

Shielded three-core (or four-core) cable; maximum transmission distance: 1000-2000 meters

Alarm Method

Audible and visual alarm (optional, alarm sound <90 dB)

Direct Reading

Measured value, max/min values

Data Download

RS485 serial port for data export

Calibration

2-4 point calibration; customizable calibration values

Explosion-proof Electrical

① NPT 3/4 internal thread (optional: 1/2 NPT, G3/4, G1/2);

② Explosion-proof cable gland (optional, certified)

Explosion-proof Mark

Ex d II CT6 Gb

Protection Level

IP66

Dimensions

180 mm (H) × 140 mm (W) × 92 mm (D)

Weight

Approx. 1.6 kg (aluminum alloy housing)

Compliance Standards

GB15322.1-2003, GB3836.1-2010, GB3836.2-2010

Quality Assurance

1-year warranty; free repair during warranty period

 

 

>>List of Commonly Detected Gas Types

NO

Detection

Range

Accuracy

T90 Response time

Resolution

Alarm set point (low/high)

1

PH3

0 – 5 ppm

±5% (F.S)

≤ 25 s

0.01 ppm

0.3 ppm/5 ppm

2

O2

0-30%Vol

±5% (F.S)

≤ 15 s

0.10% Vol

18.0%Vol/23.0%Vol

3

EX

0-100% LEL

±5% (F.S)

≤ 15 s

1% LEL

25.0%/50.0% LEL

4

CO

0 - 2000 ppm

±5% (F.S)

≤ 25 s

1 ppm

50 ppm/100 ppm

5

H2S

0 -100 ppm

±5% (F.S)

≤ 30 s

1 ppm

10 ppm/20 ppm

6

SO2

0 - 100 ppm

±5% (F.S)

≤ 30 s

0.1 ppm

2 ppm /10 ppm

7

CI2

0 - 20 ppm

±5% (F.S)

≤ 30 s

0.1 ppm

1 ppm /10 ppm

8

NH3

0 – 200 ppm

±5% (F.S)

≤ 50 s

1 ppm

25 ppm /50 ppm

9

NO2

0 - 20 ppm

±5% (F.S)

≤ 25 s

0.1 ppm

3 ppm/10 ppm

10

NO

0 - 250 ppm

±5% (F.S)

≤ 60 s

1 ppm

25 ppm/50 ppm

11

H2

0 - 1000 ppm

±5% (F.S)

≤ 60 s

1 ppm

50 ppm /100 ppm

12

HCN

0 - 50 ppm

±5% (F.S)

≤ 200 s

0.1 ppm

10 ppm /20 ppm

13

HCL

0 - 20 ppm

±5% (F.S)

≤ 60 s

0.1 ppm

5 ppm /10 ppm

14

CH4

0 - 5% Vol

±5% (F.S)

≤ 60 s

0.1% Vol

customized

15

CO2

0 - 5% Vol (0-5000ppm)

±5% (F.S)

≤ 60 s

0.01% Vol (1 ppm)

customized

16

PID(VOCs)

1-1999 ppm

±5% (F.S)

≤ 20 s

0.1 ppm

customized

17

C3H8

0 - 5%Vol

±5% (F.S)

≤ 60s

0.01% Vol

customize

18

O3

0 – 5 ppm

±5% (F.S)

≤ 30s

0.02 ppm

1ppm/2 ppm

19

SF6

0 – 1000 ppm

±5% (F.S)

≤ 60s

0.2ppm

25ppm/50 ppm

20

HF

0 – 10 ppm

±5% (F.S)

≤ 60s

0.1ppm

3ppm/10 ppm

 

Remark: Customized alarm setting points and detection ranges are also available.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2015

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is... Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Juge Environmental Technology Co., Ltd.
  • 2F, BLK A, TAIPING IND PARK, #219 JIANGJUN AVE, JIANGNING DISTRICT, NANJING, CHINA
  • https://www.environmentanalyzer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement