China Chuck Installation 20μS/cm 316L Conductivity EC Sensor Resistivity Sensor
China Chuck Installation 20μS/cm 316L Conductivity EC Sensor Resistivity Sensor

  1. China Chuck Installation 20μS/cm 316L Conductivity EC Sensor Resistivity Sensor

Chuck Installation 20μS/cm 316L Conductivity EC Sensor Resistivity Sensor

  1. MOQ: 1 Unit
  2. Price: USD50-500
  3. Get Latest Price
Packaging Details Neutral carton
Delivery Time 5-8 working days
Payment Terms Online order,T/T
Supply Ability 100 Unit/Week
Conductivity Range 0.01~20μS/cm
Resistivity Range 0.01~18.2MΩ·cm
Electrode Mode 2-pole
Electrode Constant K≈0.01
Wetted Material 316L
Temperature Range 0~150℃
Pressure Rating 0~2.0MPa
Installation Interface Chuck 50.5
Brand Name JUGE
Model Number AG3853GC
Place of Origin Nanjing, China
Certification IOS9001, CE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details Neutral carton Delivery Time 5-8 working days
Payment Terms Online order,T/T Supply Ability 100 Unit/Week
Conductivity Range 0.01~20μS/cm Resistivity Range 0.01~18.2MΩ·cm
Electrode Mode 2-pole Electrode Constant K≈0.01
Wetted Material 316L Temperature Range 0~150℃
Pressure Rating 0~2.0MPa Installation Interface Chuck 50.5
Brand Name JUGE Model Number AG3853GC
Place of Origin Nanjing, China Certification IOS9001, CE
High Light 20μs/cm conductivity sensor20μs/cm ec meter sensor316l conductivity sensor

Chuck Installation 20μS/cm 316L Conductivity EC Sensor Resistivity Sensor


>>Technical Parameter‌‌

Conductivity Range: 0.01~20 μS/cm
Resistivity Range: 0.01~18.2 MΩ·cm
Electrode Mode: 2-pole
Electrode Constant: K ≈ 0.01
Junction Material: 316L
Temperature: 0℃~150℃
Pressure Resistance: 0~2.0 MPa
Temperature Sensor: PT1000
Installation Interface: Chuck 50.5
Cable: Standard 10m


>>Principle

Since water contains various dissolved salts that exist in the form of ions, when electrodes are inserted into the water and an electric current is applied, the charged ions move in specific directions under the influence of the electric field. The anions in water migrate toward the anode, enabling the aqueous solution to conduct electricity. The ability of water to conduct electricity is termed ‌conductivity‌.

Conductivity is the reciprocal of resistivity and reflects the total dissolved salt content in water, serving as a critical indicator for assessing water quality. It reveals the concentration of electrolytes present in water. Depending on the concentration of electrolytes in an aqueous solution, the degree of electrical conduction varies. By measuring the conductivity of a solution, the solubility of electrolytes can be analyzed. This forms the fundamental analytical principle of conductivity meters.

Conductivity exhibits significant temperature dependence. For metals, conductivity decreases with rising temperatures, whereas for semiconductors, it increases with temperature. In solid semiconductors, doping levels can drastically alter conductivity—higher doping concentrations result in greater conductivity.

The conductivity of aqueous solutions depends on the concentration of dissolved salts or other chemical impurities that dissociate into electrolytes. The conductivity of a water sample serves as a key metric for measuring its salt content, ionic components, and impurity levels. Lower conductivity (higher resistivity) indicates purer water.

Water conductivity is often recorded as ‌specific conductance‌, which represents the conductivity of water at a standardized temperature of 25°C.


>>Installation Diagram

Before use, unscrew the electrode protective cap and install it with the appropriate mounting bracket or accessories.

‌1. Sidewall Installation‌: Ensure the interface tilt angle exceeds 15 degrees.

‌2. Top Flange Installation‌: Note flange dimensions and electrode insertion depth.

‌3. Pipe Installation‌: Consider pipe diameter, flow velocity, and pressure.

‌4. Flow-Through Installation‌: Monitor flow velocity and pressure.

‌5. Submersion Installation‌: Adjust bracket length as needed.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2015

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is... Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Juge Environmental Technology Co., Ltd.
  • 2F, BLK A, TAIPING IND PARK, #219 JIANGJUN AVE, JIANGNING DISTRICT, NANJING, CHINA
  • https://www.environmentanalyzer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement