Packaging Details | Neutral carton |
Delivery Time | 5-8 working days |
Payment Terms | Online order,T/T |
Supply Ability | 100 Unit/Week |
Application | General water |
ORP Range | ±1000mV |
Temperature Range | 0-80℃ |
Pressure Resistance | 0-0.6MPa |
Housing Material | Glass |
Sensitive Membrane | Platinum (Pt) |
Connection Thread | PG13.5 |
Brand Name | JUGE |
Model Number | AG2500C |
Place of Origin | Nanjing, China |
Certification | IOS9001, CE |
View Detail Information
Explore similar products
Oxidation Reduction Potential Sensor 1000mV For Heavy Metals Chloride Ions
Sodium Hypochlorite Solution Analog ORP Sensor Customized Support
High Temperature 130℃ Oxidation Reduction Potential Probe Laboratory ORP Sensor
PP Material Laboratory ORP Electrode ORP Probe With 10m Cable Length
Product Specification
Packaging Details | Neutral carton | Delivery Time | 5-8 working days |
Payment Terms | Online order,T/T | Supply Ability | 100 Unit/Week |
Application | General water | ORP Range | ±1000mV |
Temperature Range | 0-80℃ | Pressure Resistance | 0-0.6MPa |
Housing Material | Glass | Sensitive Membrane | Platinum (Pt) |
Connection Thread | PG13.5 | Brand Name | JUGE |
Model Number | AG2500C | Place of Origin | Nanjing, China |
Certification | IOS9001, CE | ||
High Light | Analog ORP Sensor 1000mV ,1000mV Oxidation reduction potential Electrode ,General water Analog ORP Sensor |
Analog ORP Probe ORP Sensor 1000mV Oxidation-reduction potential Electrode For General water
>>Technical Parameter
ORP Range: ±1000mV
Temperature Range: 0-80℃
Pressure Resistance: 0-0.6MPa
Temperature Sensor: OEM
Housing Material: Glass
Sensitive Membrane: Platinum (Pt)
Connection Thread: PG13.5
Cable Length: 5m or as agreed
Cable Connector: Pin, BNC, or as agreed
>>Overview
The core theory of pH electrode measurement is the Nernst equation. The sensor used in potentiometric analysis is called a galvanic cell. A galvanic cell is a system that converts chemical reaction energy into electrical energy. The voltage of this cell is referred to as the electromotive force (EMF). This EMF consists of two half-cells. One half-cell is the measuring sensor, whose potential is related to the activity of specific ions; the other is the reference half-cell, often called the reference sensor, which is typically connected to the measurement solution and the instrument.
ORP (Oxidation-Reduction Potential) is a critical indicator of water quality. While it cannot independently determine water quality, it reflects the ecological environment of aquatic systems by integrating other water quality parameters.
In water, each substance has its unique redox properties. Simplistically, this can be understood as: at a microscopic level, different substances possess varying oxidation-reduction capacities. These substances interact to form an overall macroscopic redox characteristic. ORP reflects the collective redox behavior of all substances in the solution. A higher ORP indicates stronger oxidizing capacity, while a lower ORP suggests weaker oxidizing capacity. A positive potential signifies oxidizing properties, whereas a negative potential indicates reducing properties.
>>Installation Diagram
Before use, unscrew the electrode protective cap and install it with the appropriate mounting bracket or accessories.
1. Sidewall Installation: Ensure the interface tilt angle exceeds 15 degrees.
2. Top Flange Installation: Note flange dimensions and electrode insertion depth.
3. Pipe Installation: Consider pipe diameter, flow velocity, and pressure.
4. Flow-Through Installation: Monitor flow velocity and pressure.
5. Submersion Installation: Adjust bracket length as needed.
>>Electrode Maintenance and Care
○ Before use, unscrew the protective cap and immerse the electrode bulb and liquid junction in the sample.
○ If salt crystals form near the electrode tip or inside the cap due to electrolyte evaporation, rinse with water. This indicates normal dialysis membrane function.
○ Check for air bubbles in the glass bulb by shaking the electrode vertically.
○ Keep the glass membrane hydrated for fast response. After measurement or calibration: Rinse the electrode thoroughly. Add storage solution (3 mol/L KCl) to the protective cap.
○ Ensure terminal connections remain dry. Clean with anhydrous alcohol if contaminated.
○ Avoid prolonged immersion in distilled water, protein solutions, or contact with silicone grease.
○ For aged electrodes with cloudy membranes or deposits, soak in 10% HCl, then rinse.
○ Regularly clean and calibrate the electrode. If calibration fails after maintenance, replace the electrode.
>>Lifespan
Under normal conditions with proper maintenance, electrodes last over 12 months. Even unused electrodes have a shelf life of 12–24 months (if stored correctly). Exposure to strong acids, bases, high temperatures, or corrosive liquids shortens lifespan. Electrodes are consumables and generally not covered by warranty.
>>Electrode Calibration
○ Use fresh pH/ORP standard buffer solutions of appropriate concentrations.
○ Remove the protective cap and rinse the electrode with distilled water.
○ Set the instrument to calibration mode (refer to the instrument manual for details).
○ After calibration, measure actual samples.
Company Details
Business Type:
Manufacturer
Year Established:
2015
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is... Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is...