China RS485 4-20mA Digital PH Sensor For Organic Solvents And Non Aqueous Phase
China RS485 4-20mA Digital PH Sensor For Organic Solvents And Non Aqueous Phase

  1. China RS485 4-20mA Digital PH Sensor For Organic Solvents And Non Aqueous Phase

RS485 4-20mA Digital PH Sensor For Organic Solvents And Non Aqueous Phase

  1. MOQ: 1 Unit
  2. Price: USD50-200
  3. Get Latest Price
Packaging Details Neutral carton
Delivery Time 5-8 working days
Payment Terms Online order,T/T
Supply Ability 100 Unit/Week
Application Organic process environments.
pH Range 0-14 pH
Accuracy ±0.05 pH
Temperature Range 0-80°C
Output RS485
Pressure Resistance ≤0.6MPa
Connection Thread NPT 3/4"
Power supply 9-36V
Brand Name JUGE
Model Number AG1797D
Place of Origin Nanjing, China
Certification IOS9001, CE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details Neutral carton Delivery Time 5-8 working days
Payment Terms Online order,T/T Supply Ability 100 Unit/Week
Application Organic process environments. pH Range 0-14 pH
Accuracy ±0.05 pH Temperature Range 0-80°C
Output RS485 Pressure Resistance ≤0.6MPa
Connection Thread NPT 3/4" Power supply 9-36V
Brand Name JUGE Model Number AG1797D
Place of Origin Nanjing, China Certification IOS9001, CE
High Light 20mA Digital PH Sensor20mA RS485 PH SensorOrganic Solvents Digital PH Sensor

Digital RS485 4-20mA Digital pH Sensor for Organic Solvents and Non-aqueous Phase Environmental Monitoring


>>Overview

Dual salt bridge design with a double-layer exudation interface, resistant to medium back infiltration. The ceramic pore-structured electrode interface minimizes clogging and is optimized for monitoring in organic solvents and non-aqueous phase environments. Featuring a high-strength glass bulb design for enhanced durability and an oversized sensing bulb that significantly improves hydrogen ion detection capability, this electrode excels in organic solvents and non-aqueous environments. Constructed with impact-resistant PP material, it demonstrates exceptional mechanical toughness and resistance to diverse organic solvents, acids, and alkalis. Equipped with a digital sensor, it offers robust anti-interference performance, high stability, and extended signal transmission range.
Applications‌: Ideal for organic solvents and non-aqueous phase environmental monitoring.


>>Feature

  • Spherical sensing bulb‌: Enlarges sensitive areas for faster response and stable signals.
  • PA+GF housing‌: Withstands high temperatures (0–80°C).
  • Quad-core shielded cable‌: High-quality dedicated wiring ensures precise signal transmission.


>>Technical Parameter

Power Supply‌: 9–36 VDC

Output‌: RS485 MODBUS RTU

Sensing Material‌: Glass/Silver + Silver Chloride; SNEX

Housing Material‌: PP (Polypropylene)

Protection Rating‌: IP68

Measurement Range‌: 0–14 pH

Accuracy‌: ±0.05 pH

Pressure Resistance‌: 0–0.6 MPa

Temperature Compensation‌: NTC10K Thermistor

Temperature Range‌: 0–80°C

Calibration‌: Sample Calibration, Standard Solution Calibration

Connection‌: 4-core Cable

Thread Type‌: NPT 3/4"

Cable Length‌: 10m or Customizable

Applications‌: Suitable for organic process environments.


>>Principle

The core theory of pH electrode measurement is the Nernst equation. The sensor used in potentiometric analysis is called a galvanic cell. A galvanic cell is a system that converts chemical reaction energy into electrical energy. The voltage of this cell is referred to as the electromotive force (EMF). This EMF consists of two half-cells. One half-cell is the measuring sensor, whose potential is related to the activity of specific ions; the other is the reference half-cell, often called the reference sensor, which is typically connected to the measurement solution and the instrument.

ORP (Oxidation-Reduction Potential) is a critical indicator of water quality. While it cannot independently determine water quality, it reflects the ecological environment of aquatic systems by integrating other water quality parameters.

In water, each substance has its unique redox properties. Simplistically, this can be understood as: at a microscopic level, different substances possess varying oxidation-reduction capacities. These substances interact to form an overall macroscopic redox characteristic. ORP reflects the collective redox behavior of all substances in the solution. A higher ORP indicates stronger oxidizing capacity, while a lower ORP suggests weaker oxidizing capacity. A positive potential signifies oxidizing properties, whereas a negative potential indicates reducing properties.


>>Installation Diagram

Before use, unscrew the electrode protective cap and install it with the appropriate mounting bracket or accessories.

‌1. Sidewall Installation‌: Ensure the interface tilt angle exceeds 15 degrees.

‌2. Top Flange Installation‌: Note flange dimensions and electrode insertion depth.

‌3. Pipe Installation‌: Consider pipe diameter, flow velocity, and pressure.

‌4. Flow-Through Installation‌: Monitor flow velocity and pressure.

‌5. Submersion Installation‌: Adjust bracket length as needed.


>>Electrode Maintenance and Care

○ Before use, unscrew the protective cap and immerse the electrode bulb and liquid junction in the sample.

○ If salt crystals form near the electrode tip or inside the cap due to electrolyte evaporation, rinse with water. This indicates normal dialysis membrane function.

○ Check for air bubbles in the glass bulb by shaking the electrode vertically.

○ Keep the glass membrane hydrated for fast response. After measurement or calibration: Rinse the electrode thoroughly. Add storage solution (3 mol/L KCl) to the protective cap.

○ Ensure terminal connections remain dry. Clean with anhydrous alcohol if contaminated.

○ Avoid prolonged immersion in distilled water, protein solutions, or contact with silicone grease.

○ For aged electrodes with cloudy membranes or deposits, soak in 10% HCl, then rinse.

○ Regularly clean and calibrate the electrode. If calibration fails after maintenance, replace the electrode.


>>Lifespan

Under normal conditions with proper maintenance, electrodes last over 12 months. Even unused electrodes have a shelf life of 12–24 months (if stored correctly). Exposure to strong acids, bases, high temperatures, or corrosive liquids shortens lifespan. Electrodes are consumables and generally not covered by warranty.


>>Electrode Calibration

○ Use fresh pH/ORP standard buffer solutions of appropriate concentrations.

○ Remove the protective cap and rinse the electrode with distilled water.

○ Set the instrument to calibration mode (refer to the instrument manual for details).

○ After calibration, measure actual samples.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2015

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is... Founded in 2015, Juge focuses on the field of environmental online monitoring and has gathered outstanding talents who have been engaged in environmental online monitoring for many years. At the same time, it cooperates with some key professional universities and research institutes in China, and is...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Juge Environmental Technology Co., Ltd.
  • 2F, BLK A, TAIPING IND PARK, #219 JIANGJUN AVE, JIANGNING DISTRICT, NANJING, CHINA
  • https://www.environmentanalyzer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement