China factories

China factory - Dongguan Precision Test Equipment Co., Ltd.

Dongguan Precision Test Equipment Co., Ltd.

  • China,Guangzhou
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Programmable Climate Test Chamber For Telecommunications Testing
China Programmable Climate Test Chamber For Telecommunications Testing

  1. China Programmable Climate Test Chamber For Telecommunications Testing
  2. China Programmable Climate Test Chamber For Telecommunications Testing
  3. China Programmable Climate Test Chamber For Telecommunications Testing

Programmable Climate Test Chamber For Telecommunications Testing

  1. MOQ: 1
  2. Price: $6000
  3. Get Latest Price
Payment Terms T/T
Supply Ability 100/month
Delivery Time 15 working days
Packaging Details Standard export packaging
Customized support OEM ODM
Origin China
Material Stainless Steel
Controller Programmable LCD Touch Screen
Temp accuracy: 0.5°C
Temp uniformity 0.5°C
Refrigerant Environmental friendly
Brand Name PRECISION
Model Number JTC-225
Certification ISO
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 100/month
Delivery Time 15 working days Packaging Details Standard export packaging
Customized support OEM ODM Origin China
Material Stainless Steel Controller Programmable LCD Touch Screen
Temp accuracy: 0.5°C Temp uniformity 0.5°C
Refrigerant Environmental friendly Brand Name PRECISION
Model Number JTC-225 Certification ISO
Place of Origin CHINA
High Light Programmable Climate Test ChamberTelecommunications Climate Test ChamberTelecommunications Testing Climate Chamber

Custom-Designed Climate Chamber Programmable for Telecommunications Testing

In the fast-paced and highly competitive telecommunications industry, the performance and durability of equipment are crucial. The custom-designed Climate Chamber Programmable for Telecommunications Testing is a specialized solution that plays a vital role in ensuring the reliability of telecommunications devices and systems.

1. Product Name and Purpose

 
This advanced climate chamber is specifically engineered to create and control a wide range of environmental conditions for testing telecommunications equipment. It caters to telecommunications manufacturers, research institutions, and network service providers. The primary objective is to evaluate how telecom devices, such as routers, switches, base stations, and antennas, perform and withstand different temperature, humidity, and other climatic variables. By subjecting these components to realistic environmental stresses, manufacturers can identify potential weaknesses, optimize designs, and ensure compliance with industry standards and network requirements.

2. Product Features

 
  • Robust and Insulated Chamber Structure
    • The chamber is constructed with a heavy-duty framework, often made of high-strength steel or aluminum alloys, to provide excellent durability and stability. The walls are insulated with high-quality materials that minimize heat transfer and maintain precise temperature and humidity levels. The door is designed with a reliable sealing mechanism and a viewing window, allowing operators to monitor the testing process without interfering with the internal environment. The interior is finished with non-conductive and non-corrosive surfaces to prevent any damage or interference to the sensitive telecom equipment.
  • Precision Temperature and Humidity Control System
    • At the core of the chamber's functionality is a sophisticated temperature and humidity control system. It can achieve a wide temperature range, typically from -40°C to +80°C, with an accuracy of ±0.3°C. The humidity control range extends from 5% to 95% relative humidity, with an accuracy of ±2% RH. The system utilizes efficient refrigeration units, heaters, humidifiers, and dehumidifiers, all coordinated by a precise PID controller. Multiple sensors are strategically placed throughout the chamber to provide real-time feedback, enabling the control system to make rapid and accurate adjustments to maintain the desired environmental conditions.
  • Programmable Testing Sequences
    • The chamber is equipped with a highly programmable control panel that allows for the creation and execution of complex testing regimens. Operators can easily set up temperature cycling, humidity cycling, and combinations of both, simulating various real-world scenarios such as seasonal changes, extreme weather events, and different geographical locations. Additionally, the chamber can be programmed to introduce other environmental factors like altitude simulation, dust ingress, and salt spray exposure, providing a comprehensive evaluation of the telecom equipment's performance and durability.
  • Intuitive Control Panel and Data Acquisition Interface
    • The user-friendly control panel simplifies the operation and parameter setting. It features a clear and intuitive interface that enables operators to adjust temperature, humidity, test durations, and other parameters with ease. The control panel also provides real-time displays of the current environmental conditions, as well as any alarms or warnings. The chamber is integrated with a comprehensive data acquisition system that records all relevant test data, including temperature and humidity histories, rate of change of environmental parameters, and any observable changes in the telecom equipment. The data can be stored in a built-in memory or exported to external storage devices for further analysis. The system can also generate detailed test reports in various formats, facilitating easy documentation and sharing of results.
  • Safety Features and Alarms
    • To ensure the safety of operators and the integrity of the testing process, the chamber is equipped with a range of safety features. These include over-temperature and over-pressure protection, emergency stop buttons, and alarms for abnormal temperature fluctuations, humidity levels, or equipment malfunctions. The safety features are designed to prevent damage to the chamber, the telecom equipment, and the surrounding environment, providing peace of mind during the testing operation.

3. Specific Parameters

 
  • Temperature Range and Accuracy
    • With a temperature range of -40°C to +80°C and an accuracy of ±0.3°C, the chamber can subject telecom equipment to a wide spectrum of temperatures. This is essential for testing the performance and reliability of devices in extreme cold and hot conditions, such as in arctic regions or desert environments. The accurate temperature control ensures that the test conditions are precisely maintained, providing reliable and repeatable results.
  • Humidity Range and Accuracy
    • The humidity range of 5% to 95% RH, with an accuracy of ±2% RH, allows for a comprehensive evaluation of the effect of moisture on telecom equipment. High humidity can cause condensation and corrosion, while low humidity can lead to static electricity and drying of components. The ability to precisely control the humidity level is crucial for understanding how these devices respond to different moisture environments.
  • Testing Volume and Payload Capacity
    • The chamber offers a customizable testing volume, typically ranging from 1 m³ to 10 m³, depending on the specific model. The payload capacity can handle a significant amount of telecom equipment, with a maximum capacity of up to 5000 kg, allowing for the testing of multiple devices or large-scale network components.
  • Data Sampling Frequency and Resolution
    • The data acquisition system samples data at a frequency of up to 500 Hz, providing a highly detailed record of the temperature, humidity, and other environmental parameter changes. The resolution of the temperature data is 0.1°C, the humidity data is 0.1% RH, and other relevant data also have high precision. This high-resolution data is invaluable for identifying even the slightest trends and potential failure points, allowing for a more accurate assessment of product performance.

4. Product Functions

 
  • Accurate Simulation of Environmental Conditions
    • The primary function of the chamber is to provide a precise and reliable simulation of the temperature, humidity, and other environmental conditions that telecom equipment may encounter. By subjecting these components to controlled environmental stresses, it allows manufacturers and researchers to evaluate their performance and durability. This is crucial for ensuring the seamless operation of telecommunications networks, as any failure in the equipment could lead to service disruptions and loss of connectivity.
  • Product Design Optimization and Quality Control
    • Company Details

      Bronze Gleitlager

      ,

      Bronze Sleeve Bushings

       and 

      Graphite Plugged Bushings

       from Quality China Factory
      • Business Type:

        Manufacturer,Exporter,Trading Company,Seller

      • Year Established:

        2006

      • Total Annual:

        5000000-10000000

      • Employee Number:

        50~100

      • Ecer Certification:

        Verified Supplier

      Since our establishment in 2006, Dongguan Precision Test Equipment Co., Ltd has been on an unwavering journey of innovation and leadership in the field of testing equipment.   Service Excellence: We pride ourselves on offering comprehensive and tailored services. Our OEM and ODM services... Since our establishment in 2006, Dongguan Precision Test Equipment Co., Ltd has been on an unwavering journey of innovation and leadership in the field of testing equipment.   Service Excellence: We pride ourselves on offering comprehensive and tailored services. Our OEM and ODM services...

      + Read More

Get in touch with us

  • Reach Us
  • Dongguan Precision Test Equipment Co., Ltd.
  • No. 6, Dongsheng Road, Xinya Street, Huadu District, Guangzhou, China
  • https://www.environmentchambers.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement