| Oleophobicity Grade | ≥ 7 |
| Operating Temperature | -40°C to +150°C |
| 90° Peel Strength | ≥ 15 N/25mm |
| Material Compliance | PFAS Free |
| Chemical Resistance | Corrosion-resistant,Acid-resistant |
| Delivery Time | 15 working days |
| Supply Ability | Monthly Output: 300,000 sqm |
| Moisture Vapor Transmission Rate | 8,000 – 18,000 g/m²·24h |
| Size | Customizable |
| Waterproof Rating | IP68 |
| Payment Terms | T/T |
| Thickness | 0.10 – 0.50 mm |
| Color | White |
| Air Permeability | Gurley:3 – 30 s/100ml @ 300 ml |
| Packaging Details | Small orders by express; bulk orders by FCL sea freight. |
| Water Entry Pressure | ≥ 400 kPa |
| Brand Name | OEM/ODM |
| Model Number | OEM/ODM |
| Certification | IATF16949/ISO |
| Place of Origin | China |
View Detail Information
Explore similar products
Weldable Waterproof Vent Membrane For Disposable Infusion / Transfusion Set
Weldable Medical Vent Membrane For Bone Cement / Orthopedic Biomaterial Mixing
Medical EPTFE Vent Weldable For IV Fluid / Parenteral Solution Bottles
Weldable Breathable Vent For Hemodialysis / Peritoneal Dialysis Solution Bags
Product Specification
| Oleophobicity Grade | ≥ 7 | Operating Temperature | -40°C to +150°C |
| 90° Peel Strength | ≥ 15 N/25mm | Material Compliance | PFAS Free |
| Chemical Resistance | Corrosion-resistant,Acid-resistant | Delivery Time | 15 working days |
| Supply Ability | Monthly Output: 300,000 sqm | Moisture Vapor Transmission Rate | 8,000 – 18,000 g/m²·24h |
| Size | Customizable | Waterproof Rating | IP68 |
| Payment Terms | T/T | Thickness | 0.10 – 0.50 mm |
| Color | White | Air Permeability | Gurley:3 – 30 s/100ml @ 300 ml |
| Packaging Details | Small orders by express; bulk orders by FCL sea freight. | Water Entry Pressure | ≥ 400 kPa |
| Brand Name | OEM/ODM | Model Number | OEM/ODM |
| Certification | IATF16949/ISO | Place of Origin | China |
| High Light | Weldable EPTFE Sterile Vent ,EtO Sterilization Medical Vent ,Gamma Sterilization EPTFE Vent | ||
The medical device packaging vent is a universal, high-performance sterile barrier component engineered for the terminal sterilization of a vast range of medical devices. It integrates a sterilizing-grade ePTFE membrane with a medical-grade, weldable thermoplastic carrier, designed for direct ultrasonic, heat-stake, or RF welding into rigid thermoformed trays, flexible pouches, and device enclosure housings. This vent provides a validated, high-gas-flow pathway for ethylene oxide (EtO) sterilant ingress and post-sterilization aeration, steam penetration during autoclaving, or hydrogen peroxide vapor during low-temperature plasma sterilization. After the cycle, it forms a permanent, 0.2-micron sterile barrier that maintains the sterility of the packaged device for its labeled shelf life—typically 3 to 5 years. The vent is compatible with gamma and e-beam radiation sterilization, making it the single vent solution for medical device manufacturers using multiple sterilization modalities across their product portfolio.
Medical device manufacturers must sterilize their products after packaging. The sterile barrier system—whether a rigid tray with a Tyvek lid, a flexible pouch, or a sealed device housing—must allow the sterilant to reach all surfaces of the device and then be fully evacuated. EtO gas, the most common industrial sterilant, must penetrate the packaging, contact the device, and then be removed through aeration to reduce toxic residues to safe levels. Steam sterilization requires rapid pressure and temperature cycling that can burst sealed packages if not properly vented. Hydrogen peroxide vapor sterilization requires deep vacuum and precise gas exposure. A universal vent that performs reliably across all these sterilization methods simplifies the supply chain and packaging validation for the device manufacturer. The vent must maintain its sterile barrier integrity through distribution, handling, and years of warehouse storage.
The weldable medical device packaging vent provides a single, validated component for multi-modality sterilization. The ePTFE membrane is chemically inert and thermally stable, withstanding EtO gas, steam at 134°C, vaporized H₂O₂, and high doses of gamma and e-beam radiation without any degradation of its physical or barrier properties. The thermoplastic carrier is material-matched to the common medical packaging polymers—PETG, PP, PE, PC—for a fast, strong, repeatable weld. During sterilization, the vent provides a high-airflow pathway for sterilant ingress and egress. After sterilization, the 0.2-micron pore structure provides a permanent sterile barrier. The vent is also designed to equalize pressure during the air shipment of packaged devices, preventing the pouch "ballooning" or tray lid "popping" that can compromise sterility.
| Parameter | Specification |
|---|---|
| Product Type | Weldable Medical Device Packaging Vent |
| Carrier Material | PETG, PP, PE, PC (matched to tray/pouch) |
| Membrane Material | Medical-grade ePTFE |
| Pore Size | 0.2 μm (sterilizing-grade) |
| Bacterial Retention | ≥ 10⁷ CFU/cm² per ASTM F838 |
| Airflow | ≥ 1000 ml/min @ 1 psi |
| Sterilization Compatibility | EtO, steam (121°C / 134°C), H₂O₂ plasma, gamma, e-beam |
| Post-Sterilization Shelf Life | ≥ 5 years (validated) |
| Operating Temperature | -40°C to +140°C |
| Installation | Ultrasonic, heat-stake, or RF welding |
| Package Integrity | Meets ASTM F1929, F2096 for dye penetration and burst testing |
Rigid thermoformed medical device trays (PETG, PP, PS)
Flexible medical pouches and header bags
Catheter and tubing set packaging
Implantable device sterile barrier systems
Single-use surgical instrument packaging
Sterile procedure kit and drape packaging
Wound care and advanced dressing sterile packaging
The vent is welded into a dedicated port on the thermoformed tray, pouch film, or device housing during the packaging process. The packaged device enters the sterilization chamber. During EtO sterilization, the gas penetrates the package through the vent membrane, contacts the device, and after the dwell time, is evacuated back through the vent during the aeration phase. During steam sterilization, the vent allows air removal during the pre-vacuum pulses and steam penetration during the exposure phase, then filtered air ingress during drying. After the cycle, the vent membrane's 0.2-micron pores provide a continuous, passive sterile barrier. The package can be shipped globally, and the vent equalizes pressure during altitude changes in air freight, protecting the package seals.
Identify all sterilization methods used for the device to select a vent that is fully compatible with each process.
Determine the packaging material and select a matching vent carrier for optimal weld compatibility.
Calculate the package internal volume and the required sterilant and aeration flow rates to size the vent appropriately.
Validate the complete sterile barrier system per ISO 11607: bacterial challenge, seal integrity testing, and accelerated and real-time aging.
For EtO sterilization, validate the aeration efficiency and residual EtO levels with the vented package design.
Q: Can a single vent be validated for both EtO and gamma sterilization?
A: Yes, the ePTFE membrane and weldable carrier are resistant to both EtO chemistry and gamma radiation up to 50 kGy and beyond. We provide a single vent that supports multi-modality sterilization validation.
Q: Will the vent slow down the EtO aeration process?
A: No, the vent's high airflow capacity facilitates efficient aeration. The package design with the vent can often reduce aeration time compared to a package relying solely on Tyvek or paper permeability.
Q: Is the vent compatible with the hydrogen peroxide plasma used in STERRAD systems?
A: Yes, ePTFE is chemically resistant to vaporized H₂O₂ and withstands the deep vacuum levels of plasma sterilization cycles without degradation.
Q: How is the vent's sterile barrier validated for the claimed 5-year shelf life?
A: We conduct accelerated aging per ASTM F1980 at elevated temperatures to simulate 5 years of real-time aging, followed by bacterial challenge testing to confirm barrier maintenance.
Q: Can the vent be used in a package that undergoes both sterilization and aseptic presentation (e.g., in an operating room)?
A: Yes, the vent is integral to the sterile barrier system. The package can be opened and presented aseptically in the sterile field according to standard operating room protocols.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2018
Total Annual:
1,000,000-2,000,000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
Kunshan Xinzhenpin New Thin Film Material Technology Co., Ltd. Established in 2018, Kunshan Xinzhenpin is a specialized manufacturer dedicated to ePTFE waterproof and breathable membrane solutions. We operate a fully integrated production chain covering ePTFE raw membrane manufacturing, composite a... Kunshan Xinzhenpin New Thin Film Material Technology Co., Ltd. Established in 2018, Kunshan Xinzhenpin is a specialized manufacturer dedicated to ePTFE waterproof and breathable membrane solutions. We operate a fully integrated production chain covering ePTFE raw membrane manufacturing, composite a...
Get in touch with us
Leave a Message, we will call you back quickly!