Products
Manufacturer of a wide range of products which include Industrial Oxygen Gas Analyzer Sensor L Lambda Probe Mesa EM2020 103-1510 530-3555 103-1513 530-3551 For Measuring Chamber MK 2 MK 2.1 Industrial process Heat treatment unit G...
MOQ: NO MOQ
Price: Inquire
| Condition | New, 100% Brand New |
| Fitting thread: | M 18 |
| Measuring gas temperature: | < 200 °C |
| Supply Ability | Inquire |
| Climate: | Storage:-40...+100 °C |
| Operation: | 0...+100 °C 5...95% relative humidity, noncondensing |
| Applications | Industrial process Heat treatment unit Gas analysis Environmental engineering |
| Measuring range: | 100 %O2 ... 10-26 %O2 |
| Package | Common Package or Personalized Customization Package |
| OE NO. | EM 2020 |
| Sensor element: | Zirconium dioxide pipe |
| Service | OEM ODM |
| Delivery Time | Inquire |
| Logo/graphic design | Laser Printing |
| Payment Terms | L/C,D/A,D/P,T/T |
| Connection (1m lead, can be also 2,3m): | Heating voltage: plug Probe signal: socket |
| Packaging Details | Common Package or Personalized Customization Package |
| Warranty | 1 Year |
| Measuring gas flow: | approx... 40 l/h |
| Reaction time for 220°C gas: | ≤ 2s for rising from 25 mV to 44 mV |
| Type | Oxygen Sensor |
| Certification | CE,RoHS |
| Place of Origin | China guangdong |
| Brand Name | EVOzuRun |
| Model Number | EM2020 |
MOQ: 1
Price: $359-439
| Universal Fitment | Yes |
| Material | Platinum,High-purity copper ,Plastic |
| Condition | New, 100% Brand New |
| Type | Oxygen Sensor |
| Service | OEM ODM |
| Car Make | for SICK Flue Gas Analyzer MCS100FT |
| OE NO. | 6086558 |
| Warranty | 1 Year |
| Logo/graphic design | Laser Printing |
| Chip Material | Imported High-precision Chip |
| Purpose | for replace/repair |
| Package | Common Package or Personalized Customization Package |
| Place of Origin | China guangdong |
| Model Number | 6086558 |
| Brand Name | EVOzuRun |
MOQ: 1
Price: $529-553
| Condition | New, 100% Brand New |
| OE NO. | AS210KX721045BA |
| Type | Oxygen Sensor |
| Service | OEM ODM |
| Car Make | for Industrial Analyzer Detector |
| Universal Fitment | Yes |
| Material | Platinum,High-purity copper ,Plastic |
| Logo/graphic design | Laser Printing |
| Chip Material | Imported High-precision Chip |
| Package | Common Package or Personalized Customization Package |
| Purpose | for replace/repair |
| Warranty | 1 Year |
| Model Number | AS-210KX-721045-BA |
| Place of Origin | China guangdong |
| Brand Name | EVOzuRun |
MOQ: 1
Price: $462-513
| Condition | New, 100% Brand New |
| Type | Oxygen Sensor |
| Service | OEM ODM |
| Car Make | For Inert Gas Control System Analyzer |
| OE NO. | AS210 |
| Universal Fitment | Yes |
| Material | Platinum,High-purity copper ,Plastic |
| Warranty | 1 Year |
| Logo/graphic design | Laser Printing |
| Chip Material | Imported High-precision Chip |
| Purpose | for replace/repair |
| Package | Common Package or Personalized Customization Package |
| Place of Origin | China guangdong |
| Model Number | AS-210 |
| Brand Name | EVOzuRun |
MOQ: NO MOQ
Price: Inquire
| Analog Output | Air-point plus up to three-point calibration Air one-point calibration Calibration via data input (during sensor replacement) Analog Output;DC 4–20 mA, non-isolated output, load resistance ≤600 Ω DC 0–1 V / DC 0–5 V / DC 0–10 V, selectable (non-isolated ou |
| Contact Output | Open collector output, DC 25 V max. 50 mA Number of contacts: 4 outputs Selectable functions: Analyzer fault / Range echo-back 1 / Range echo-back 2 / Range echo-back 3 / Ready / High concentration alarm / Low concentration alarm |
| Delivery Time | Inquire |
| Calibration | Air-point plus up to three-point calibration Air one-point calibration Calibration via data input (during sensor replacement) |
| Range Switching | Local range switching / Remote range switching / Auto range switching |
| Sensor element: | Zirconium dioxide pipe |
| Output Hold Function | Output hold value setting: No hold* / User-defined value / Value 5 seconds before fault occurrence *Output held during warm-up and analyzer fault |
| High/Low Concentration Alarm | High alarm: Configurable from 0.0–9,990.0 ppm or 0.0–100.0% Low alarm: Configurable from 0.0–9,990.0 ppm or 0.0–100.0% |
| Packaging Details | Common Package or Personalized Customization Package |
| Payment Terms | L/C,D/A,D/P,T/T |
| Measuring Principle | Zirconia type limiting current method |
| Measuring range: | Min. 0–1,000 ppm to Max. 0–25%; Any four ranges selectable with fixed zero point *Output range configurable from 0–10 ppm to 0–100% |
| Accuracy | ±1% FS;±2% FS |
| RS-232C Communication Function | Transmits measurement status, error code, measurement range, and measured value Communication cable specification: D-sub 9-pin, straight cable |
| Sample & Calibration Gas Flow Rate | 0.5 L/min |
| Response Time | ≤60 seconds (below 0–1,000 ppm), ≤30 seconds (0–1,000 ppm and above) (90% response when switching calibration gas) |
| OE NO. | TF-30D201 (TF-30 Sensor + DTF-201 Receiver) |
| Power Supply | AC specification: AC 100–240 V ±10%, 50/60 Hz, 50 VA ;DC specification: DC 24 V ±10%, 50 W |
| Contact Input | Range switching (voltage-free contact) |
| Supply Ability | Inquire |
| Applications | Reflow furnaces Ferrite firing furnaces Other atmosphere management and combustion control applications |
| Drift | ≤±2% FS per week |
| Model Number | TF-30D201 (TF-30 Sensor + DTF-201 Receiver) |
| Certification | CE,RoHS |
| Brand Name | EVOzuRun |
| Place of Origin | China guangdong |
MOQ: NO MOQ
Price: Inquire
| Payment Terms | T/T,D/P,D/A,L/C |
| Calibration | Air-point calibration plus up to four additional points (Calibration possible for each measurement range) |
| Response Time | ≤30 seconds (below 0–1% range), ≤10 seconds (0–1% range and above) (90% response when switching calibration gas) |
| Contact Input | Range switching (voltage-free contact) |
| Product Name | TF-30D201 Zirconia Oxygen Analyzer |
| Output Hold Function | Output hold value setting: No hold* / User-defined value / Value 5 seconds before fault occurrence *Output held during warm-up and analyzer fault |
| Model | Zirconia Oxygen Analyzer |
| Range Switching | Local range switching / Remote range switching / Auto range switching |
| Delivery Time | Inquire |
| Measuring Principle | Zirconia type concentration cell method |
| Sample & Calibration Gas Flow Rate | 0.5 L/min |
| Contact Output | Open collector output, DC 25 V max. 50 mA Number of contacts: 4 outputs Selectable functions: Analyzer fault / Range echo-back 1 / Range echo-back 2 / Range echo-back 3 / Ready / High concentration alarm / Low concentration alarm |
| Power Supply | AC specification: AC 100–240 V ±10%, 50/60 Hz, 50 VA DC specification: DC 24 V ±10%, 50 W |
| Packaging Details | Common Package or Personalized Customization Package |
| Accuracy/Repeatability | ±1% FS (below 0–1% range), ±0.5% FS (0–1% range and above) |
| Measuring Range | Min. 0–10 ppm to Max. 0–25%; Any four ranges selectable with fixed zero point *Output range configurable from 0–10 ppm to 0–100% |
| Drift | ≤±2% FS per week |
| High/Low Concentration Alarm | High alarm: Configurable from 0.0–9,990.0 ppm or 0.0–100.0% Low alarm: Configurable from 0.0–9,990.0 ppm or 0.0–100.0% |
| OE NO. | TF-30D201 741934634 971351824 |
| Supply Ability | Inquire |
| Analog Output | DC 4–20 mA, non-isolated output, load resistance ≤600 Ω DC 0–1 V / DC 0–5 V / DC 0–10 V, selectable (non-isolated output) |
| Linearity | ±3% FS (below 0–100 ppm range), ±2% FS (below 0–1% range), ±1% FS (0–1% range and above) |
| Applications | Semiconductor manufacturing equipment, atmosphere measurement in various N2 furnaces, air separation units |
| RS-232C Communication Function | Transmits measurement status, error code, measurement range, and measured value Communication cable specification: D-sub 9-pin, straight cable |
| Brand Name | EVOzuRun |
| Model Number | Ntron Microx-231 |
| Certification | CE,RoHS |
| Place of Origin | China guangdong |
MOQ: NO MOQ
Price: Inquire
| Model | Zirconia Oxygen Analyzer |
| Delivery Time | Inquire |
| Measuring Principle | Zirconia type concentration cell method |
| Sample & Calibration Gas Flow Rate | 0.5 L/min |
| Contact Input | Range switching (voltage-free contact) |
| Power Supply | AC 100–240 V, 50/60 Hz, 50 VA |
| Packaging Details | Common Package or Personalized Customization Package |
| Accuracy/Repeatability | ±1% FS (below 0–1% range), ±0.5% FS (0–1% range and above) |
| Payment Terms | T/T,D/P,D/A,L/C |
| Calibration | Air-point calibration plus up to four additional points (Calibration possible for each measurement range) |
| Response Time | ≤30 seconds (below 0–1% range), ≤10 seconds (0–1% range and above) (90% response when switching calibration gas) |
| External Dimensions | 96 (W) × 96 (H) × 170 (D) (Receiver) |
| Product Name | TF-SD201R AS-210 Zirconia Oxygen Analyzer |
| Applications | Semiconductor manufacturing equipment, atmosphere measurement in various N2 furnaces, air separation units |
| Measuring Range | 0-5, 10, 25% / −15 to 25, −6 to 10, −3 to 5% |
| Drift | ≤±2% FS per week |
| Supply Ability | Inquire |
| Analog Output | DC 4–20 mA, non-isolated output, load resistance ≤600 Ω DC 0–1 V / DC 0–5 V / DC 0–10 V, selectable (non-isolated output) |
| Linearity | ±3% FS (below 0–100 ppm range), ±2% FS (below 0–1% range), ±1% FS (0–1% range and above) |
| OE NO. | TF-SD201R AS-210 DTF-201R RX-621310 DTF-201R RX-622310-A RE-210 KX-621020-A421D KX-721045-B/A |
| Model Number | Ntron Microx-231 |
| Brand Name | EVOzuRun |
| Place of Origin | China guangdong |
| Certification | CE,RoHS |
MOQ: NO MOQ
Price: Inquire
| Payment Terms | T/T,D/P,D/A,L/C |
| Model | Microx-231 |
| Measurement Range | 1 ppm–25% O₂, Auto-Ranging |
| Process Connection | M18 Thread (Optional KF40 Flange) |
| Power Supply Requirement | 24 VDC |
| Gas Temperature | 600°C |
| Delivery Time | Inquire |
| Measurement Accuracy | ±2% of Reading at 20°C |
| Sample Gas Pressure | Vented to Atmosphere During Operation or Calibration |
| Sensor Type | LP Zirconia |
| Supply Voltage | 24 VDC (Optional 220 VAC) |
| Packaging Details | Common Package or Personalized Customization Package |
| OE NO. | Microx-231 |
| Communication Interface | RS-232 |
| Warm-Up Time | 3 Minutes |
| Relay Outputs | 3 Relays |
| Signal Output | 4–20 mA |
| Supply Ability | Inquire |
| Manufacturer | Ntron |
| Response Time (T90) | <10 Seconds |
| Sensor Life | 3–5 Years |
| Chip Material | Imported High-precision Chip |
| Ingress Protection | IP54 |
| Material | Platinum,High-purity copper ,Plastic |
| Relative Humidity | 0–95% RH, Non-Condensing |
| Model Number | Ntron Microx-231 |
| Certification | CE,RoHS |
| Brand Name | EVOzuRun |
| Place of Origin | China guangdong |
MOQ: NO MOQ
Price: Inquire
| Payment Terms | T/T,D/P,D/A,L/C |
| Model | Microx-231 |
| Measurement Range | 1 ppm–25% O₂, Auto-Ranging |
| Process Connection | M18 Thread (Optional KF40 Flange) |
| Power Supply Requirement | 24 VDC |
| Gas Temperature | 600°C |
| Delivery Time | Inquire |
| Measurement Accuracy | ±2% of Reading at 20°C |
| Sample Gas Pressure | Vented to Atmosphere During Operation or Calibration |
| Sensor Type | LP Zirconia |
| Supply Voltage | 24 VDC (Optional 220 VAC) |
| Packaging Details | Common Package or Personalized Customization Package |
| OE NO. | Microx-231 |
| Supply Ability | Inquire |
| Manufacturer | Ntron |
| Communication Interface | RS-232 |
| Warm-Up Time | 3 Minutes |
| Relay Outputs | 3 Relays |
| Signal Output | 4–20 mA |
| Response Time (T90) | <10 Seconds |
| Sensor Life | 3–5 Years |
| Chip Material | Imported High-precision Chip |
| Ingress Protection | IP54 |
| Material | Platinum,High-purity copper ,Plastic |
| Relative Humidity | 0–95% RH, Non-Condensing |
| Model Number | Ntron Microx-231 |
| Certification | CE,RoHS |
| Brand Name | EVOzuRun |
| Place of Origin | China guangdong |
MOQ: NO MOQ
Price: Inquire
| Power Supply Requirement | 24 VDC |
| Material | Platinum,High-purity copper ,Plastic |
| Sample Gas Pressure | Vented to Atmosphere During Operation or Calibration |
| Payment Terms | T/T,D/P,D/A,L/C |
| Model | Microx-231 |
| Signal Output | 4–20 mA |
| Gas Temperature | 600°C |
| Sensor Life | 3–5 Years |
| Packaging Details | Common Package or Personalized Customization Package |
| Measurement Range | 1 ppm–25% O₂, Auto-Ranging |
| Warm-Up Time | 3 Minutes |
| Supply Voltage | 24 VDC (Optional 220 VAC) |
| Delivery Time | Inquire |
| Measurement Accuracy | ±2% of Reading at 20°C |
| Relative Humidity | 0–95% RH, Non-Condensing |
| OE NO. | Microx-231 |
| Ingress Protection | IP65 |
| Response Time (T90) | <10 Seconds |
| Chip Material | Imported High-precision Chip |
| Supply Ability | Inquire |
| Communication Interface | RS-232 |
| Manufacturer | Ntron |
| Relay Outputs | 3 Relays |
| Sensor Type | LP Zirconia |
| Process Connection | M18 Thread (Optional KF40 Flange) |
| Model Number | Ntron Microx-231 |
| Certification | CE,RoHS |
| Brand Name | EVOzuRun |
| Place of Origin | China guangdong |
Explore more categories