Payment Terms | T/T |
Supply Ability | 30 sets/month |
Delivery Time | 30 days |
Packaging Details | Carton Box |
DC high voltage | Max. 12.5kV |
Instrument internal resistance | 12Ω ± 10% and 500Ω± 10% |
Peak voltage | 300 V~ 12,500V |
Impact cycles | 1 ~ 9999 |
Impact interval time | 5 ~ 99s |
Working power source | ~ 220V±10%, 50Hz/60Hz |
Dimension | 430mm×180mm×480mm |
Weight | 20 KG |
Brand Name | Sinuo |
Model Number | SN1104 |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
IEC 61851 EVSE Testing Equipment Charging Station Waterproof Test Room
PLC Control EVSE Testing Equipment Cord Cantilever Tensile And Rocking Life
Clause 16 EVSE Testing Equipment Electric Vehicle Marking Durability IEC 61851
EVSE Tracking Index Test Apparatus CTI PTI IEC 61851-1 PLC Control
Product Specification
Payment Terms | T/T | Supply Ability | 30 sets/month |
Delivery Time | 30 days | Packaging Details | Carton Box |
DC high voltage | Max. 12.5kV | Instrument internal resistance | 12Ω ± 10% and 500Ω± 10% |
Peak voltage | 300 V~ 12,500V | Impact cycles | 1 ~ 9999 |
Impact interval time | 5 ~ 99s | Working power source | ~ 220V±10%, 50Hz/60Hz |
Dimension | 430mm×180mm×480mm | Weight | 20 KG |
Brand Name | Sinuo | Model Number | SN1104 |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
12.5kV IEC 61851 Test Equipment EVSE Impulse Voltage Test Machine
Complied Standards & Clauses
The Impulse Test Generator conforms to the standard requirements of IEC 61851-1 clause 12.7, IEC 61851-23 clause 11.4, etc.
Equipments Overview
It is used to verify that the appliances shall withstand the transient over-voltages to which they may be subjected. The impulse voltage test is a destructive test in which a breakdown occurs if the test specimen cannot withstand the applied voltage. When the sample breaks down, sparks and discharge sounds will be generated. The peak voltage of the instrument will drop significantly (close to zero) when it is no-load. When the same voltage is applied again, the above phenomenon will occur.
Technical Parameters
DC high voltage | Max. 12.5kV |
Impulse voltage wave | Impulse wavefront time: 1.2 µs ± 30 %; Half value of after wave time: 50 µs ± 20 % Please note that the waveform should be checked on an external oscilloscope |
Instrument internal resistance | 12Ω ± 10% and 500Ω± 10% |
Peak voltage: 300 V~ 12,500V | 300-12500V, Low: 300 V~ 2,500V; High: 2,500 V~ 12,500V |
Impact interval time | 5 ~ 99s |
Impact cycles | 1 ~ 9999 |
Polarity | positive and negative |
Working power source | Rated voltage: ~ 220V±10%, 50Hz/60Hz |
Dimension | 430mm×180mm×480mm |
Weight | 20 KG |
Details
Company Details
Business Type:
Manufacturer
Year Established:
2019
Employee Number:
<100
Ecer Certification:
Verified Supplier
Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te... Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te...
Get in touch with us
Leave a Message, we will call you back quickly!