Payment Terms | T/T |
Supply Ability | 10 Sets Per Month |
Delivery Time | 30 Days |
Packaging Details | Export packing |
Effective volume | 48m3 |
Temperature range | -30℃~+60℃ |
Humidity fluctuation | ≤±2.0%R.H |
Humidity range | 20%〜98%RH |
Heating rate | -30℃~+60℃ About 2~3℃/min |
Cooling rate | +60℃~-30℃ About 0.7~1℃/min |
External dimensions Approx. | 4250 mm*3580 mm*5200 mm(W*H*D) |
Inner box dimensions | 4000 mm*3000 mm*4000mm(W*H*D) |
Brand Name | Sinuo |
Model Number | SN886-48m³ |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
Constant Temperature Humidity walk in environmental test chamber 13m3 less than
IEC60529 IP5/6X EV Charge Station Walk-In Sand & Dust Test Chamber
IEC 60068 Temperature Humidity Walk In Environmental Test Chambers
50m³ Walk In Temperature Humidity Environment Stability Test Chamber
Product Specification
Payment Terms | T/T | Supply Ability | 10 Sets Per Month |
Delivery Time | 30 Days | Packaging Details | Export packing |
Effective volume | 48m3 | Temperature range | -30℃~+60℃ |
Humidity fluctuation | ≤±2.0%R.H | Humidity range | 20%〜98%RH |
Heating rate | -30℃~+60℃ About 2~3℃/min | Cooling rate | +60℃~-30℃ About 0.7~1℃/min |
External dimensions Approx. | 4250 mm*3580 mm*5200 mm(W*H*D) | Inner box dimensions | 4000 mm*3000 mm*4000mm(W*H*D) |
Brand Name | Sinuo | Model Number | SN886-48m³ |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
Climatic Test Chamber Environmental Walk-in Temperature and Humidity Test Chamber 48m³
Complied Standards & Clauses
Conforms to:
IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”
IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”
IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”
IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”
Product Overview
The walk-in constant temperature and humidity test room is suitable for safety performance testing, reliability testing, product screening testing, etc. of electronic components. At the same time, through these tests, the reliability of the product is improved and the quality control of the product is carried out.
The walk-in constant temperature and humidity test room is an essential test equipment in the fields of aviation, automobiles, home appliances, scientific research, etc. Sample range: electrical, electronic, semiconductor, communication, optoelectronics, electrical appliances, automotive electrical appliances, materials and other products. This equipment is used to assess and determine the parameters, performance, and adaptability of the above samples after the high and low temperature and humidity tests with rapid changes in temperature environment.
It is suitable for schools, factories, military industry, research and development and other units.
Technical Parameters
Volume and Size | |
Effective volume | 48m3 |
Inner box dimensions | W:4000 mm H: 3000 mm D: 4000 mm |
External dimensions Approx. | W: 4250 mm H: 3580 mm D: 5200 mm |
Performance (ambient temperature -5℃~+28℃, no-load condition) | ||
Temperature range | -30℃~+60℃ | |
Heating rate | -30℃~+60℃ About 2~3℃/min (no load, average) | |
Cooling rate | +60℃~-30℃ About 0.7~1℃/min(no load, average) | |
Resolution accuracy | 0.01℃ | Data measured under no-load conditions |
Temperature fluctuation | ±0.5℃ | |
Temperature deviation | ±2.0℃ | |
Humidity range | 20%~98%RH | |
Humidity deviation | Below 75%RH: ≤±5.0%RH Above 75%RH: ≤+2/-3%R.H | |
Humidity fluctuation | ≤±2.0%R.H | |
Temperature and humidity control capability range diagram | ![]() | |
Load conditions | Allow max. 4KW calorific value during testing | |
Power source for UUT |
| |
Power supply | AC3¢5W 380V 60Hz (R, STN three-phase five-wire plus ground wire) (voltage fluctuation ≤ ±10%) | |
Power | The total power of the equipment is about 45KW | |
Noise | Measured according to GB/T14623-2008, the noise level is ≤75dB (the noise detection device is measured at a distance of 1m from the equipment door). | |
Standards | IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT” IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT” IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT” IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT” |
Details
Company Details
Business Type:
Manufacturer
Year Established:
2019
Employee Number:
<100
Ecer Certification:
Verified Supplier
Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te... Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te...
Get in touch with us