China factories

Chat Now Send Email
China factory - E-link China Technology Co., Ltd.

E-link China Technology Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Hardened L2+ 24-Port Gigabit Switch with 4 SFP USB-C Easy Management
China Hardened L2+ 24-Port Gigabit Switch with 4 SFP USB-C Easy Management

  1. China Hardened L2+ 24-Port Gigabit Switch with 4 SFP USB-C Easy Management
  2. China Hardened L2+ 24-Port Gigabit Switch with 4 SFP USB-C Easy Management

Hardened L2+ 24-Port Gigabit Switch with 4 SFP USB-C Easy Management

  1. MOQ: 1 pcs
  2. Price: $305-$325
  3. Get Latest Price
Payment Terms T/T,Western Union,MoneyGram,paypal,Credit Card
Supply Ability 1000pcs/month
Delivery Time 5-12working days
Packaging Details Fiber Optic Switch Standard Export Package
Interface: 24 × 10/100/1000 RJ45, 4 × 1000Base-X SFP
Management USB-C, Web, CLI, SNMP v1/v2/v3, Telnet, Cloud (MQTT)
Power Input 12–48VDC redundant, overload/reverse polarity protection
Power Consumption ≤ 8W
Housing IP40-rated aluminum, DIN-rail mount
Operating Temp -40°C to +80°C
Brand Name E-link
Model Number ETH-DIMC2424M
Certification CE, RoHS, FCC, ISO9001
Place of Origin Guangdong, China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,Western Union,MoneyGram,paypal,Credit Card Supply Ability 1000pcs/month
Delivery Time 5-12working days Packaging Details Fiber Optic Switch Standard Export Package
Interface: 24 × 10/100/1000 RJ45, 4 × 1000Base-X SFP Management USB-C, Web, CLI, SNMP v1/v2/v3, Telnet, Cloud (MQTT)
Power Input 12–48VDC redundant, overload/reverse polarity protection Power Consumption ≤ 8W
Housing IP40-rated aluminum, DIN-rail mount Operating Temp -40°C to +80°C
Brand Name E-link Model Number ETH-DIMC2424M
Certification CE, RoHS, FCC, ISO9001 Place of Origin Guangdong, China

Hardened L2+ 24-Port Gigabit Switch with 4 SFP USB-C Easy Management

Overview

The ETH-DIMC2424M Series is not just another industrial Ethernet switch — it combines

24 Gigabit RJ45 ports, 4 SFP uplinks, and a USB-C management interface that

replaces traditional RS232 for faster, simpler deployment. Engineered with a fanless IP40

aluminum case, -40°C to +80°C temperature tolerance, and redundant 12~48VDC

power inputs, it ensures uninterrupted connectivity in extreme conditions. With advanced

L2+ features including VLAN, QoS, ERPS ring redundancy, and robust security such as

SSH/HTTPS/802.1X, it delivers enterprise-grade reliability to industrial networks.

Features

Unique USB-C management port – no need for RS232 serial access

24 × Gigabit RJ45 + 4 × SFP ports, 110Gbps switching capacity

Hardened IP40 aluminum chassis, fanless & vibration-resistant

Wide -40°C to +80°C operation for harsh environments

Redundant 12~48VDC power with automatic reset protection

Advanced redundancy: STP/RSTP/MSTP/ERPSv2 ring recovery

Robust security: SSH, HTTPS, RADIUS, 802.1X, DoS/DDoS defense

Industrial protocols support: IGMP Snooping, QoS, ACL, VLAN Q-in-Q

High reliability: MTBF > 200,000 hrs, CE/FCC/EN/IEC certified

Technical Indexes

Ethernet

Standards:

IEEE802.3 10BASE-T

IEEE802.3u 100BASE-TX/FX

IEEE802.3ab 1000BASE-T

IEEE802.3z 1000BASE-X

IEEE802.3p QoS

IEEE802.1d Spanning Tree

Forward & Filtering Rate:

14,880pps (10Mbps)

148,800pps (100Mbps)

1,488,000pps (1000Mbps)

Packet Buffer Memory:

12M bits

Processing Type:

Store-and-Forward

Backplane bandwidth

110Gbps

Max Packet Length:

10K Bytes Jumbo Frame

Address Table Size:

8K MAC Addresses

Interface

Connector:

24 x RJ45

RS485:

1 x RS485 (Optional)

Optical Port:

4 x 1000Base-X SFP

USB-C:

1 x USB-C (for Management)

RS485 Serial Interface (Optional)

Physical interface

Industrial standard 3-pin screw terminal

Data type

1Ch RS485 Bi-Direction

RS-485 signals

Data+, Data-, GND

Serial port line distance (copper)

1000 meters

Baud rate

0 ~ 800kbps

Environmental

Operating Temperature:

-40°C to 80°C (-40°F to 176°F)

Storage Temperature:

-40°C to 85°C (-40°F to 185°F)

Relative Humidity:

5% to 95% non-condensing

MTBF

> 200,000 hrs

Electrical and Mechanical

Input Power:

12~48VDC, Redundant Power (6-pin Terminal Block)

Power Consumption:

8W Max 

Protection:

Power Input Overload:

Automatic Resettable

Reverse Polarity:

Present

DIP Switch

4-digit DIP switch function

DIP

Function

Settings

SW 1

VLAN

ON - Enabled

OFF - Disabled

SW 2

Ring Management

ON - Enabled

OFF - Disabled

SW 3

Reserved

ON - Reserved

OFF - Reserved

SW 4

Reserved

ON - Reserved

OFF - Reserved

LED Indicators:

PWR:

Power Status

Ethernet (Per Port):

Link/Activity

RJ45 Port

(T1~T24)

Fiber:

Gigabit SFP Port: F25~F28

Dimensions (WxDxH):

155 x 115 x 85 mm

Weight:

1.2KG

Casing:

Aluminum Case

Mounting Options:

DIN-Rail mount

Software Features

Redundancy Protocols

Support STP/RSTP/MSTP/ERPSv2, Link Aggregation

Multicast Support

Support IGMP Snooping V1/V2/V3,support GMRP, GVMP,802.1Q

VLAN

Support IEEE 802.1Q 4K VLAN,support QINQ, Double VLAN,

Time Management

SNTP

QOS

Flow-based redirection

Flow-based rate limiting
Flow-based packet filtering
8*Output queues of each port 802.1p/DSCP priority mapping
Diff-Serv QoS, Priority Mark/Remark
Queue Scheduling Algorithm (SP, WRR, SP+WRR)

ACL

Port-based Issuing ACL

ACL based on port and VLAN
L2 to L4 packet filtering, matching first 80 bytes message.
Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc

Diagnostic Maintenance

Support port mirroring, Syslog, Ping

Management Function

Support CLI, WEB, SNMPv1/v2/v3, Telnet server for management, EEE, LLDP, DHCP Server/Client(IPv4/IPv6), Cloud/MQTT

Alarm Management

Support 1 way relay alarm output, RMON, TRAP

Security

Broadcast Storm Protection, HTTPS/SSLv3, AAA & RADIUS, SSH2.0

Support DHCP Snooping, Option 82,802.1X security access,
Support user hierarchical management, ACL access control list,
Support DDOS,port-based MAC filtering / binding, MAC black holes, IP source protection, Port isolation, ARP message speed limit

Advance Layer 2+ Features

IPv4/IPv6 Management

Static Route

Regulatory Approvals

ISO9001, CE, RoHS, FCC

EN55022:2010+AC: 2011, Class A

EN 61000-3-2: 2006+A1: 2009+A2: 2009

EN 61000-3-3: 2013

EN55024:2010

IEC 61000-4-2: 2008 (ESD)

IEC 61000-4-3: 2010 (RS)

IEC 61000-4-4: 2012 (EFT)

IEC 61000-4-5: 2014 (Surge)

IEC 61000-4-6: 2013 (CS)

IEC 61000-4-8: 2009 (PFMF)

Ordering Information

Model

Description

ETH-DIMC2424M

Industrial L2+ 24-Port 10/100/1000T + 4-Port 1000X SFP Managed Ethernet Switch

SFP Options

► SFP option. Please select your SFP on our SFP Options Page 

► SFP module is to be purchased separately.

Mounting Options

► Default DIN-Rail Bracket installed

Power Options

► DIN-Rail Power Supply. Open Wire for Terminal Block.

► Power Supply is to be purchased separately.

Application

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2001

  • Total Annual:

    10000000-20000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Established in 2001& headquartered in Shenzhen, E-link China Technology Co., Ltd. (E-link) is a leading Fiber Optic Communication and CCTV Security Transmission product manufacturer in China. Our main products include active equipments including fiber media converters, CCTV fiber converters... Established in 2001& headquartered in Shenzhen, E-link China Technology Co., Ltd. (E-link) is a leading Fiber Optic Communication and CCTV Security Transmission product manufacturer in China. Our main products include active equipments including fiber media converters, CCTV fiber converters...

+ Read More

Get in touch with us

  • Reach Us
  • E-link China Technology Co., Ltd.
  • 5F, Building D South, Jinshenghui Science Park, No. 3, Dafu Road, Fucheng Street, Guanlan, Longhua District, Shenzhen, China
  • https://www.fiberethernetmediaconverter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement