Name | IPX3 IPX4 Rain Test Chamber |
Standard | IEC 60529 |
Power supply | AC220V single-phase three-wire, 50Hz |
Power | 3 kw |
Size | 1900×1560×2110㎜(width*depth*height) |
Enclosure | SUS304 stainless steel |
Brand Name | Gold |
Model Number | GD-IEC60589-W |
Certification | ISO |
Place of Origin | China |
View Detail Information
Explore similar products
High Quality IEC 60529 IP5X IP6X Sand And Dust Test Chamber for IP protection
3 Cubic Meter Room Cable Smoke Density Tester IEC 61034 Standard Micro
IEC 61034 3m3 Wire And Cable Smoke Density Tester Smoke Transmittance Test
ISO 6941 Lab Test Equipment Vertical Flame Tester For Fabric And Textlite
Product Specification
Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1 per 30 days |
Delivery Time | 30 days | Packaging Details | Plywood box |
Name | IPX3 IPX4 Rain Test Chamber | Standard | IEC 60529 |
Power supply | AC220V single-phase three-wire, 50Hz | Power | 3 kw |
Size | 1900×1560×2110㎜(width*depth*height) | Enclosure | SUS304 stainless steel |
Brand Name | Gold | Model Number | GD-IEC60589-W |
Certification | ISO | Place of Origin | China |
High Light | IPX3 IPX4 rain test chamber ,electronics rain test chamber ,automotive waterproof test chamber |
IEC 60529 IPX3 IPX4 Rain Test Chamber
Product Introduction
This product is suitable for testing electrical products, enclosures, and seals to ensure the proper performance of equipment and components in rainy conditions. Its scientific design enables it to realistically simulate various water spray, splashing, and spraying environments, testing the physical and other related properties of the product.
It is widely used for testing the physical and other related properties of electronic and electrical products, lamps, electrical cabinets, electrical components, automobiles, coaches, buses, motorcycles, and their parts under simulated rainy conditions. After testing, verification is used to determine whether the product's performance meets the requirements, facilitating product design, improvement, verification, and factory inspection.
Standards:
IPX3 and IPX4 protection levels as specified in GB4208-2017 Degrees of Protection Enclosures (IP Code);
IPX3 and IPX4 protection levels as specified in IEC 60529:2013 Degrees of Protection Enclosures (IP Code). ISO 20653:2006 Road Vehicles — Degrees of Protection (IP Code) — IPX3 and IPX4 Degrees of Protection for Electrical Equipment Against Foreign Objects, Water, and Contact;
GB 2423.38-2005 Electric and Electronic Products — Environmental Testing — Part 2 — Test R — Water Test Methods and Guidelines — IPX3 and IPX4 Degrees of Protection;
IEC 60068-2-18:2000 Electric and Electronic Products — Environmental Testing — Part 2 — Test R — Water Test Methods and Guidelines — IPX3 and IPX4 Degrees of Protection.
Technical Performance
Inner Box Dimensions: 1400 × 1400 × 1400 mm (W * D * H)
Outer Box Dimensions: Approximately 1900 × 1560 × 2110 mm (W * D * H) (actual dimensions subject to change)
Spray Hole Diameter: 0.4 mm
Spray Hole Spacing: 50 mm
Oscillating Pipe Radius: 600 mm
Oscillating Pipe Total Water Flow: IPX3: 1.8 L/min; IPX4: 2.6 L/min
Spray Hole Flow Rate:
1.Sprays within a ±60° angle from vertical, maximum distance 200 mm;
2.Sprays within a ±180° angle from vertical;
3.(0.07 ±5%) L/min per hole multiplied by the number of holes
Nozzle Angle: 120° (IPX3), 180° (IPX4)
Oscillating Angle: ±60° (IPX3), ±180° (IPX4)
Spray Hose Oscillating Speed IPX3: 15 times/min; IPX4: 5 times/min
Rainwater pressure: 50-150kPa
Test duration: 10 minutes or more (adjustable)
Preset test time: 1s to 9999H59M59s, adjustable
Turntable diameter: 800mm; Load capacity: 20kg
Turntable speed: 1-3 rpm (adjustable)
Inner/outer case material: SUS304 stainless steel/iron plate, spray-coated with plastic
Working environment
1. Operating voltage: AC220V single-phase three-wire, 50Hz. Power: Approximately 3kW. A separate 32A air switch must be installed. The air switch must have wiring terminals. The power cord must be ≥ 4 square meters. 2. Water Inlet and Drain Pipes: After planning the equipment placement, please install the circuit breaker next to it in advance. Install the water inlet and drain pipes below the circuit breaker. The water inlet pipe (a four-branch pipe with a valve) and the drain pipe (a four-branch pipe) should be flush with the floor.
3. Ambient Temperature: 15°C to 35°C;
4. Relative Humidity: 25% to 75% RH;
5. Atmospheric Pressure: 86kPa to 106kPa.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2008
Ecer Certification:
Verified Supplier
Since 2008, GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on. Quality and Certification: We always adhere to a strict quality control system, and all produ... Since 2008, GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on. Quality and Certification: We always adhere to a strict quality control system, and all produ...