Chongqing gold mechnical and electrical equipment Co., Ltd
| Payment Terms | L/C,D/P,D/A,T/T,Western Union |
| Supply Ability | 1 per 60 works days |
| Delivery Time | 60 works day |
| Packaging Details | plywood box |
| Name | High,Medium,Low-expansion foam liquid foaming multiple and liquid separation time measuring instrument |
| Standard | EN 1568 ,UL 162,NFPA 11 |
| Test area | High,Medium,Low-expansion foam liquid foaming multiple and liquid separation time |
| liquid separation time | 25,50% |
| operating pressure range | 0.3–0.65 MPa |
| Foam material | AFFF |
| Brand Name | Gold |
| Model Number | Gd-EN1568 |
| Certification | ISO |
| Place of Origin | China |
View Detail Information
Explore similar products
IEC 60811-401 Natural Ventilation Aging Test Chamber for cable and plastic
High Quality IEC 60529 IP5X IP6X Sand And Dust Test Chamber for IP protection
IEC 60529 IPX3 IPX4 Rain Test Chamber Waterproof Testing Machine for Electronics
EN 54-10 infrared and ultraviolet flame detectors Inspection apparatus
Product Specification
| Payment Terms | L/C,D/P,D/A,T/T,Western Union | Supply Ability | 1 per 60 works days |
| Delivery Time | 60 works day | Packaging Details | plywood box |
| Name | High,Medium,Low-expansion foam liquid foaming multiple and liquid separation time measuring instrument | Standard | EN 1568 ,UL 162,NFPA 11 |
| Test area | High,Medium,Low-expansion foam liquid foaming multiple and liquid separation time | liquid separation time | 25,50% |
| operating pressure range | 0.3–0.65 MPa | Foam material | AFFF |
| Brand Name | Gold | Model Number | Gd-EN1568 |
| Certification | ISO | Place of Origin | China |
| High Light | EN 1568 foam liquid measuring instrument ,foam expansion testing equipment ,liquid separation time measurement device | ||
EN 1568 High,Medium,Low-expansion foam liquid foaming multiple and liquid separation time measuring instrument
![]()
This precision testing instrument is specifically designed to evaluate the foam expansion ratio, 25% drainage time, and 50% drainage time (25%/50%) of high-expansion, medium-expansion, and low-expansion foam solutions.
The instrument features a stainless steel foam collection tank, high-precision flow control (operating pressure range 0.3–0.65 MPa), and an automated timing system (supporting dual-threshold automatic recording of 25% and 50%), ensuring accurate and repeatable test results.
The system supports international standards such as ISO 7203-1-2, EN 1568-1-2-3, UL 162, and NFPA 11, making it ideal for global certification testing. it ensures reliable performance for foam concentrate manufacturers, fire safety labs, and regulatory compliance teams.
This equipment/system meets the following standards for determining foam expansion ratio, 25% drainage time, and 50% drainage time, covering low-expansion, medium-expansion, and high-expansion foams:
2.1 Complies with GB 15308-2006 "Foam Extinguishing Agents"
Section 5.8: Determination of expansion ratio, 25% and 50% drainage time for low-expansion foam solutions (expansion ratio 1–20).
Section 5.9: Determination of expansion ratio, 25% and 50% drainage time for medium-expansion and high-expansion foam solutions (medium-expansion 21–200, high-expansion >200).
2.2 Complies with GB 19156-2019 "General Technical Conditions for Fire Monitors"
Section 6.4.4.1: Determination of expansion ratio and drainage time (applicable to low-expansion, medium-expansion, and high-expansion foams, supporting 25%/50% measurements, including temperature correction).
2.3 Complies with GB 20031-2005 "General Technical Requirements for Foam Fire Extinguishing Systems and Components"
Section 6.20.2: Determination of Expansion Ratio and Drainage Time (supports low, medium, and high expansion ratios, including 25%/50%).
2.4 Complies with UL 162-2024 "Foam Equipment and Liquid Concentrates"
Section 10.2: Determination of Expansion Ratio and Drainage Time for Foam Equipment and Concentrates (primarily 25%, expansion ratio ≤20:1; 50% can be supplemented).
2.5 Complies with EN 1568 Series:2018 "Fire extinguishing media — Foam concentrates"
EN 1568-1:2018 — Medium Expansion Foam Concentrate (20:1~200:1), Determination of Expansion Ratio and 25%/50% Drainage Time.
EN 1568-2:2018 — Determination of expansion ratio and 25%/50% drainage time for high-expansion foam concentrate (>200:1).
EN 1568-3:2018 — Determination of expansion ratio and 25%/50% drainage time for low-expansion foam concentrate (≤20:1).
2.6 Complies with NFPA 11-2024 "Standard for Low-, Medium-, and High-Expansion Foam" Determination of expansion ratio and drainage time for low-, medium-, and high-expansion foam systems (primarily the 25% drainage time, recommended by Annex D; 50% can be added for high-expansion systems).
2.7 Complies with ISO 7203 series:2019 "Fire extinguishing media — Foam concentrates"
ISO 7203-1:2019 — Determination of expansion ratio and 25% (and 50%) drainage time for low-expansion foam concentrates (≤20:1).
ISO 7203-2:2019 — Determination of expansion ratio and 25% (and 50%) drainage time for medium-expansion and high-expansion foam concentrates (20:1 to 200:1 and >200:1).
Equipment Compatibility Specification
This measuring device is designed to meet various standard requirements for low-, medium-, and high-expansion foams (supporting 25% and 50% eluent extraction times):
Foaming Ratio Testing: Utilizing a standard foam gun (such as a PQ4/PQ8 low-/medium-expansion gun, or an adapted high-expansion generator) and the graduated cylinder/collection bucket method, it precisely controls flow rate, pressure, and air intake to achieve foaming ratio measurements for low (≤20:1), medium (20:1~200:1), and high (>200:1) expansion ratios. It complies with the flow control and data acquisition requirements of ISO 7203-1/7203-2, EN 1568-1/2/3, NFPA 11, GB 15308-2006 (5.8/5.9), and GB 19156-2019.
Sedimentation Time Measurement: The sedimentation receiving tank is made of brass/stainless steel and equipped with an automatic timing function and a screen-type drainage device. It supports simultaneous or separate accurate measurement of 25% and 50% sedimentation times (volume or mass basis, automatically switching or recording as required by standards). It meets the accuracy and stability requirements of UL 162, NFPA 11 (Annex D), GB 20031-2005 (6.20.2), GB 15308-2006 (5.8/5.9, including 25%/50%), EN 1568 series, and ISO 7203 series.
The proportional control valve and electromagnetic flowmeter ensure stable liquid supply pressure (0.3–0.65 MPa), which is compatible with the test conditions of ASTM D1881.
1 Composition: It consists of a standard compressed air foam system with high, medium, and low expansion foam collectors and a foam separation tester.
2 Low-multiple foam generation system: It consists of an air inlet pipe, a pressure-resistant storage tank, a pressure gauge, a foam liquid delivery pipe, and an adjustable bracket;
Fig. 1 Installation diagram of low magnification foam generation system
2.1 Standard foam gun: When calibrated with water, at a pressure of (0.63±0.03)MPa, the water flow rate is (11.4±0.4)L/min;
Fig. 2 Schematic diagram of standard foam gun
Figure 3. Picture of Standard foam Gun
2.2 Low-expansion foam collector: See Figure 4, made of stainless steel;
Figure 4. Schematic diagram of a low-expansion foam collector
2.3. Liquid analyzer: See Figure 5, made of brass; calibrate the volume of the foam receiving tank with water to an accuracy of 1 mL;
Figure 5. Liquid separation measuring device
3.Medium-multiple foam generation system:
Figure 6. Schematic diagram of the installation of the medium-expansion foam generation system
3.1 Medium-strength foaming liquid;
3.2 Foam generator: When calibrated with water, at a pressure of (0.5±0.01) MPa, the water flow rate is (3.25±0.15) L/min;
3.3 Foam collector: 200L volume, volume accuracy ±2L, with 9 drain holes at the bottom, made of stainless steel;
Figure 7. Schematic diagram of a medium-expansion foam collector
3.4 Graduated cylinder: 10mL graduation;
3.5 Thermometer: 1℃ graduation;
3.6 Stopwatch: 0.1s graduation;
3.7 Platform scale: 0.01kg accuracy;
4. High-multiple foam generation system:
Figure 8. Installation diagram of high-expansion foam generation system
4.1 High-concentration foaming liquid;
4.2 Foam generator: When calibrated with water, at a pressure of (0.5±0.01) MPa, the water flow rate is (6.1±0.1) L/min;
4.3 Foam collector: 500L volume, volume accuracy ±5L, with 9 drain holes at the bottom, made of stainless steel;
Figure 9. Schematic diagram of a high-expansion foam collector
4.4 Graduated cylinder: 10mL graduation;
4.5 Thermometer: 1℃ graduation;
4.6 Stopwatch: 0.1s graduation;
4.7 Platform scale: 0.01kg accuracy;
1 Air compressor: 0.8MPa, flow rate 30L/min;
2 Thermometer: graduation value 1℃, mercury thermometer;
3 Measuring cylinder: 500mL, graduation value 10mL;
4 Balance: 1000g/0.1g;
5 Stopwatch: graduation value 0.1s.
1 Ambient temperature: (15~25)℃
2 Foam temperature: (15~20)℃
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2008
Ecer Certification:
Verified Supplier
Since 2008, Chongqing GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on. Quality and Certification:We always adhere to a strict quality control system, and all products ... Since 2008, Chongqing GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on. Quality and Certification:We always adhere to a strict quality control system, and all products ...
Get in touch with us