Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building","imgUrl":"https:\/\/img.chinax.com\/nimg\/d8\/d3\/84db7fc34112a11428a2c3b3cd0a-200x200-1\/iso_9869_u_value_testing_wall_heat_transfer_performance_tester_for_building.jpg","attrs":{"Standard":"ISO 9869","Model Number":"GD-ISO 9869","Measuring range":"-20 ~ +20mV","Minimum Order Quantity":"1"}}
{"title":"Low Temperature General Purpose Thermal Conductivity Meter ASTM C1113 ASTM D5930","imgUrl":"https:\/\/img.chinax.com\/nimg\/b3\/7c\/3b42e14ae544d78ea511c663b3be-200x200-1\/low_temperature_general_purpose_thermal_conductivity_meter_astm_c1113_astm_d5930.jpg","attrs":{"Model Number":"GD-ASTM C1113","Standard":"ASTM C1113,ASTM D5930,GB\/T 10297,GB\/T 11205","Working Environment":"0~40 \u00b0C, \u2264 65% RH","Delivery Time":"30 days"}}
{"title":"Thermal Conductivity Device ASTM C518 ISO 8301 for Thermal Insulation Materials","imgUrl":"https:\/\/img.chinax.com\/nimg\/4f\/09\/d9d30f85a7ec8477fce80c18b57c-200x200-1\/thermal_conductivity_device_astm_c518_iso_8301_for_thermal_insulation_materials.jpg","attrs":{"Model Number":"GD-ASTM C518","Standard":"ASTM E1530,ASTM C518,ISO 8301","Minimum Order Quantity":"1 set","Delivery Time":"30 days"}}
{"title":"ISO 12567 Thermal Insulation Performance Testing Equipment for Doors and Windows","imgUrl":"https:\/\/img.chinax.com\/nimg\/67\/0c\/fe9be124536607cc7fe5b147abde-200x200-1\/iso_12567_thermal_insulation_performance_testing_equipment_for_doors_and_windows.jpg","attrs":{"Model Number":"GD-ISO 12567","Payment Terms":"L\/C,D\/A,D\/P,T\/T","Standard":"ISO 12567","sample size":"1800\u00d72100 mm or high(customize)"}}
{"title":"ASTM C518 ISO 8301 Thermal Conductivity Tester Heat Flow Meter for Insulation","imgUrl":"https:\/\/img.chinax.com\/nimg\/a8\/05\/337e6482dad15c89e41dd3c20cef-200x200-1\/astm_c518_iso_8301_thermal_conductivity_tester_heat_flow_meter_for_insulation_materials_testing.jpg","attrs":{"standard":"ASTM C518 ISO 8301","Brand Name":"Gold","Model Number":"GD-ASTMC518","Certification":"ISO"}}
ISO 9869 U-value Testing Wall Heat Transfer Performance Tester
The ISO 9869 Wall Heat Transfer Performance Tester is developed in accordance with testing requirements for building envelope heat transfer coefficients specified in EN ISO 9869-1 and GB/T23483-2009. This instrument is dedicated to on-site detection of heat transfer coefficients for building walls and roofs.
Product Overview
Mount heat flow meters and temperature sensors on inner wall surfaces, with temperature sensors placed on outer wall surfaces. The instrument collects relevant data within specified test periods, deriving heat transfer coefficients through data calculation and analysis. Features stable on-site data transmission, simple structure, easy installation, and convenient maintenance.
Working Conditions
Operating environment temperature: -40℃ to 80℃
Relative humidity: Less than 90%
Power supply: 220VAC, 50Hz
Reference Standards
EN ISO 9869-1: In-situ measurement of thermal resistance and thermal transmittance of building components using heat flow meters
GB/T 23483-2009: Test Methods for Heat Transfer Coefficient of Building Envelope and Heating Heat Supply
Technical Parameters
Temperature Measurement Sensors
Quantity: 6 pieces per case
Resolution: 0.0625℃; Uncertainty: < 0.5℃
Digital type, used to measure surface temperatures of measuring points
Heat Flux Density Sensors
Measuring points: 3 points per case
Measuring range: -20 to +20mV
Resolution: 0.001 mV
Measurement accuracy: ≤ 0.02 mV
Plate-type heat flow meter for building envelope structures
Data Acquisition Instrument
Touch screen controlled, collects temperature and heat flux density data, automatically calculates and displays thermal resistance and heat transfer coefficient in real time.
Hot Box
Temperature rise range: More than 10℃ above outdoor ambient temperature
Automatically sets internal temperature according to outdoor ambient changes
Enables year-round detection capability
Wireless data transmission with built-in data storage
Data Processing Software
Processes and analyzes test data in Excel tables
Dual display modes: numerical value and curve
Direct test report printing capability
Test Capacity
One single wall per test
Installation Method
Outer wall temperature sensors: Paste sensors on selected outer surface measuring points, securely connect wires to indoor box body.
Hot box installation: Hoist to proper height, apply thermal conductive silicone grease, paste temperature and heat flow sheets on measuring points, press hot box tightly against wall with clamping fixture.
On-site data connection: Connect power supply, turn on operation switch, check channel communication via "Signal Inspection" interface, start detection when all channels are normal.
Instrument Operation Instructions
Test Interface
Interface switching via right-side buttons: "Box Switching" for Box A/B/C selection; "Signal Inspection" for channel status; "Curve View" for parameter curves; "Parameter Setting" for test parameters.
Parameter Setting Interface
Set inner/outer surface heat transfer resistance according to standards or use defaults
Demonstration mode: Set to 0 for actual use
Test method: 0 for hot box method (inner wall hotter), 1 for cold box method (outer wall hotter)
Storage interval: Default 1min, set according to test requirements
Note: All parameters must remain within specified setting ranges.
Sensor Calibration Interface
Configure zero drift of temperature sensors and coefficient of heat flow meter sheets.
Sampling Record Interface
"Delete all stored data": Permanently deletes all sampling data (use with caution after data export)
"Refresh stored data": For abnormal data refresh situations
File naming: Automatic (Year-Month-Day Hour.csv) or manual naming with .csv suffix
Export data to USB flash drive as Excel csv file format
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2008
Ecer Certification:
Verified Supplier
Since 2008, Chongqing GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on.