China ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building
China ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building

  1. China ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building
  2. China ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building
  3. China ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building
  4. China ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building
  5. China ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building

ISO 9869 U-value testing Wall Heat Transfer Performance Tester for Building

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Standard ISO 9869
Measuring range -20 ~ +20mV
Delivery Time 60 works days
Packaging Details plywood box
Payment Terms L/C,D/P,D/A,T/T
Name Wall Heat Transfer Performance Tester
Measurement accuracy ≤ 0.02 mV
Power supply 220VAC, 50Hz
Supply Ability 1 pcs per 60 works day
Test method Heat flow meter method
Model Number GD-ISO 9869
Brand Name Gold
Place of Origin China
Certification ISO

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Standard ISO 9869 Measuring range -20 ~ +20mV
Delivery Time 60 works days Packaging Details plywood box
Payment Terms L/C,D/P,D/A,T/T Name Wall Heat Transfer Performance Tester
Measurement accuracy ≤ 0.02 mV Power supply 220VAC, 50Hz
Supply Ability 1 pcs per 60 works day Test method Heat flow meter method
Model Number GD-ISO 9869 Brand Name Gold
Place of Origin China Certification ISO
High Light ISO 9869 U-value wall tester ,building thermal performance tester ,heat transfer tester for energy-saving
ISO 9869 U-value Testing Wall Heat Transfer Performance Tester
The ISO 9869 Wall Heat Transfer Performance Tester is developed in accordance with testing requirements for building envelope heat transfer coefficients specified in EN ISO 9869-1 and GB/T23483-2009. This instrument is dedicated to on-site detection of heat transfer coefficients for building walls and roofs.
ISO 9869 Wall Heat Transfer Performance Tester equipment setup and components
Product Overview
Mount heat flow meters and temperature sensors on inner wall surfaces, with temperature sensors placed on outer wall surfaces. The instrument collects relevant data within specified test periods, deriving heat transfer coefficients through data calculation and analysis. Features stable on-site data transmission, simple structure, easy installation, and convenient maintenance.
Working Conditions
  • Operating environment temperature: -40℃ to 80℃
  • Relative humidity: Less than 90%
  • Power supply: 220VAC, 50Hz
Reference Standards
  • EN ISO 9869-1: In-situ measurement of thermal resistance and thermal transmittance of building components using heat flow meters
  • GB/T 23483-2009: Test Methods for Heat Transfer Coefficient of Building Envelope and Heating Heat Supply
Technical Parameters
Temperature Measurement Sensors
  • Quantity: 6 pieces per case
  • Resolution: 0.0625℃; Uncertainty: < 0.5℃
  • Digital type, used to measure surface temperatures of measuring points
Heat Flux Density Sensors
  • Measuring points: 3 points per case
  • Measuring range: -20 to +20mV
  • Resolution: 0.001 mV
  • Measurement accuracy: ≤ 0.02 mV
  • Plate-type heat flow meter for building envelope structures
Data Acquisition Instrument
Touch screen controlled, collects temperature and heat flux density data, automatically calculates and displays thermal resistance and heat transfer coefficient in real time.
Hot Box
  • Temperature rise range: More than 10℃ above outdoor ambient temperature
  • Automatically sets internal temperature according to outdoor ambient changes
  • Enables year-round detection capability
  • Wireless data transmission with built-in data storage
Data Processing Software
  • Processes and analyzes test data in Excel tables
  • Dual display modes: numerical value and curve
  • Direct test report printing capability
Test Capacity
One single wall per test
Installation Method
  1. Outer wall temperature sensors: Paste sensors on selected outer surface measuring points, securely connect wires to indoor box body.
  2. Hot box installation: Hoist to proper height, apply thermal conductive silicone grease, paste temperature and heat flow sheets on measuring points, press hot box tightly against wall with clamping fixture.
  3. On-site data connection: Connect power supply, turn on operation switch, check channel communication via "Signal Inspection" interface, start detection when all channels are normal.
Instrument Operation Instructions
Test Interface
Interface switching via right-side buttons: "Box Switching" for Box A/B/C selection; "Signal Inspection" for channel status; "Curve View" for parameter curves; "Parameter Setting" for test parameters.
Parameter Setting Interface
  • Set inner/outer surface heat transfer resistance according to standards or use defaults
  • Demonstration mode: Set to 0 for actual use
  • Test method: 0 for hot box method (inner wall hotter), 1 for cold box method (outer wall hotter)
  • Storage interval: Default 1min, set according to test requirements
Note: All parameters must remain within specified setting ranges.
Sensor Calibration Interface
Configure zero drift of temperature sensors and coefficient of heat flow meter sheets.
Sampling Record Interface
  • "Delete all stored data": Permanently deletes all sampling data (use with caution after data export)
  • "Refresh stored data": For abnormal data refresh situations
  • File naming: Automatic (Year-Month-Day Hour.csv) or manual naming with .csv suffix
  • Export data to USB flash drive as Excel csv file format

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2008

  • Ecer Certification:

    Verified Supplier

Since 2008, Chongqing GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on. Quality and Certification:We always adhere to a strict quality control system, and all products ... Since 2008, Chongqing GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on. Quality and Certification:We always adhere to a strict quality control system, and all products ...

+ Read More

Get in touch with us

  • Reach Us
  • Chongqing gold mechnical and electrical equipment Co., Ltd
  • 25F, China Resources Building, Xiejiawan, Jiulongpo District,Chongqing,400050,China
  • https://www.firetestequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement