Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash |
Supply Ability | 30 sets per month |
Delivery Time | 15 work days after order confirmed |
Packaging Details | Wooden case |
Name | ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine |
Temperature | 300℃ |
Accuracy | 5% |
Power supply | AC 220V; 50HZ |
Standard | ASTM D5470 |
Heat flow range | 0.5-2000W/m2 |
The timing part range | 0 ~ 999.9s; resolution 0.1s; |
Warranty | 12 months |
Brand Name | DAXIAN |
Model Number | DX8377A |
Certification | ASTM D5470 |
Place of Origin | China |
View Detail Information
Explore similar products
ASTME 136-22 Fire Testing Equipment Non Combustibility AC220V
ASTM E 108-04 Solar Cell Burning Brand Flammability Test Chamber , Flame Test
IEC60332-1 Flame Propagation Test For A Single Insulated Cable Test Equipment
ISO 1182 Lab Testing Equipment Micro Computer Non Combustibility Building
Product Specification
Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash | Supply Ability | 30 sets per month |
Delivery Time | 15 work days after order confirmed | Packaging Details | Wooden case |
Name | ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine | Temperature | 300℃ |
Accuracy | 5% | Power supply | AC 220V; 50HZ |
Standard | ASTM D5470 | Heat flow range | 0.5-2000W/m2 |
The timing part range | 0 ~ 999.9s; resolution 0.1s; | Warranty | 12 months |
Brand Name | DAXIAN | Model Number | DX8377A |
Certification | ASTM D5470 | Place of Origin | China |
High Light | ASTM D5470 thermal conductivity tester ,300℃ thermal testing machine ,lab thermal conductivity analyzer |
ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine
Scope of application:
Thermal conductivity of dry test pieces of clay and sand, the thermal resistance of the sample should be greater than 0.1m2.K / W.
A thermal flow meter is used to detect the thermal conductivity and thermal resistance of clay, sand, etc., and the computer is used to realize automatic detection and generate an experimental report. The instrument adopts a stable hot surface temperature on the side of the sample, and the heat is transferred to the cold surface (room temperature) through the sample, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance. Specially equipped with geotechnical sample cylinder and specific heat capacity test device, which can be used for thermal conductivity analysis and specific heat capacity determination of clay, sand and other soils.
Standard:
ASTM D5470-12 (Test Standard for Heat Transfer Properties of Thin ThermalConductive Solid Electrical insulation Materials), etc.
Technical parameters:
1. Thermal conductivity range:
Plate-like sample 0.015-400W/mk, accuracy better than 5%; Cylindrical sample 3-400W/mk, accuracy less than 5%;
(A round sample cylinder with rock-finish soil, Ф90mm)
2. Hot surface temperature: room temperature -99.99 °C, the use of high digital display meter temperature measurement, 0.2 precision, resolution 0.01 °C.
3. Cold surface temperature: room temperature, using a high digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C.
4. Hot surface temperature control: room temperature -99.99 °C, using a high number of digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C, flat heater, two-way SCR control.
5. Cold forced air cooling. The cold side is water-cooled to ensure stable cold face temperature (optional for temperature users)
6. Using computer automatic testing.
7. Heat flow range: 0.5-2000W/m2, delivery rate of 0.25 W/m2.
8. Using WPY heat flow meter, heat flow parameters 23.26w/m2.mV.
9. Using plexiglass windshield, can directly observe the experimental process.
10. Uot and cold plate heat transfer area: 150 × 150 (mm), (can be manufactured according to user requirements 300/300,600/600 and other specifications of the sample).
11. Adjustable hot and cold plate spacing: 0-160 (mm).
The main technical parameters:
The test range | 0.1 ~ 300w/m • k |
Power supply | AC 220V; 50HZ |
Heat source | heating copper block, using 36V safe voltage heating. |
Test materials | block or cylindrical metal, non-metallic materials, can test powder, gelatinous and other samples; |
Measuring temperature range | room temperature ~ 250 °C, up to 550 °C, accuracy ± 1 °C; |
The timing part | range 0 ~ 999.9s; resolution 0.1s; |
Thermal conductivity measurement accuracy | better than 10% |
Sample size | Φ130 × (1-100) mm |
FAQ |
Q:Are you factory or trading company?
A:We are factory in Dongguan City, Guangdong Province,China.Near Shenzhen or Guangzhou.
Q:What kind of certificate you have?
A:ISO9001 Certification, CE Certification.
Q:What is the lead time of the product?
A: Generally 7-15 days after getting the deposit.
Q:How about the payment term?
A: T/T, by cash, western union, or L/C.
Q:How about the warranty term?
A:1 year warranty,The engineer can teach the machine on the spot.
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
8,000,000-10,000,000
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Daxian is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment 1. Fire Testing Equipment 2. Building Material Fire Tester 3. Wire and Cable Fire Tester 4. Environmental Test Chamber 5. Textile Testing Equipment ... Daxian is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment 1. Fire Testing Equipment 2. Building Material Fire Tester 3. Wire and Cable Fire Tester 4. Environmental Test Chamber 5. Textile Testing Equipment ...
Get in touch with us
Leave a Message, we will call you back quickly!