China factories

Chat Now Send Email
China factory - Flo-Instruments Co., Ltd

Flo-Instruments Co., Ltd

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China ST505 Ultrasonic Flow Meter with Relay Output and RS485 Communication for 24V DC
China ST505 Ultrasonic Flow Meter with Relay Output and RS485 Communication for 24V DC

  1. China ST505 Ultrasonic Flow Meter with Relay Output and RS485 Communication for 24V DC
  2. China ST505 Ultrasonic Flow Meter with Relay Output and RS485 Communication for 24V DC
  3. China ST505 Ultrasonic Flow Meter with Relay Output and RS485 Communication for 24V DC
  4. China ST505 Ultrasonic Flow Meter with Relay Output and RS485 Communication for 24V DC

ST505 Ultrasonic Flow Meter with Relay Output and RS485 Communication for 24V DC

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Accuracy ±1% of measured value
Power Supply 24V DC
Delivery Time 3-5 working days
Repeatability 0.3% of measured value
Velocity Range 0.03~±16 ft/s (0.01~±5 m/s)
Pipe Size 1"~48" (25 mm~1200 mm)
Communication RS485
Payment Terms T/T
Packaging Details Conventional Packaging
Model Number ST505
Certification CE; ISO9001
Brand Name Flo-Instru
Place of Origin ShenZhen

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Accuracy ±1% of measured value Power Supply 24V DC
Delivery Time 3-5 working days Repeatability 0.3% of measured value
Velocity Range 0.03~±16 ft/s (0.01~±5 m/s) Pipe Size 1"~48" (25 mm~1200 mm)
Communication RS485 Payment Terms T/T
Packaging Details Conventional Packaging Model Number ST505
Certification CE; ISO9001 Brand Name Flo-Instru
Place of Origin ShenZhen
High Light Relay Output Ultrasonic Flow Meter ,RS485 Communication Ultrasonic Flow Meter ,24V DC Ultrasonic Flow Meter
ST505 Stationary Ultrasonic Flowmeter

Integrate into your management system to provide remote measurement services.

The ST505 Ultrasonic Flow Meter uses the most reliable digital signal processing technology, transmitting flow measurement for a wide range of liquid and pipe sizes with high accuracy and reliability. Combined with outstanding performance transducers and higher industrial-level materials, Flo-Instruments flow meters can operate for long periods without concern.

Clear menu display selections make using the instrument very convenient. Clamp-on transducers make the unit more flexible over a wide range of applications.

The ST505 ultrasonic flowmeter is based on Transit-Time technology, which provides high measurement accuracy. The ST505 uses a clamp-on transducer that collects flow data simply by clamping onto the outside of the pipe. It never comes into contact with the fluid, so it will not cause liquid pollution, pressure reduction, leakage, or similar issues.

Benefits
  • Measures the actual flow and total consumption of various liquids.
  • No loss of process control, optimization of assets and efficiency, no downtime or expense from calibration.
  • Adaptive signal processing algorithms optimize performance, ensuring accurate measurements even in challenging flow conditions.
  • Clear display interface and LCD display with alarm function, easy to operate and debug.
  • Utilizes transit-time ultrasonic technology to realize bidirectional flow measurement by precisely measuring the time it takes for ultrasonic signals to travel upstream and downstream.
  • Leverages data logging capabilities to analyze historical flow patterns for system optimization.
  • Built-in keypad and simple menu system for fast and easy programming of pipe diameter, pipe material, liquid type, and measurement units.
Dimensions
ST505 ultrasonic flow meter transmitter dimension drawing with front and side views

Transmitter dimensions

ST505 ultrasonic flow meter transmitter front panel and mounting dimensions

Transmitter

ST505 clamp-on ultrasonic transducer dimension drawing with side and top views

Transducer

Technical Specifications
Performance Specifications
Velocity Range 0.03~±16 ft/s (0.01~±5 m/s)
Accuracy ±1% of measured value
Repeatability 0.3% of measured value
Pipe Size 1" ~ 48" (25 mm ~ 1200 mm)
Power Supply 24V DC
Keypad 16 touch buttons
Display (20×2) alphanumeric, backlit LCD
Function Specifications
Output Analog output: 4~20 mA, max load 750Ω
Pulse output: 0~9999 Hz, OCT (min. and max. frequency adjustable)
Relay output: max 1 Hz (1A @ 125V AC or 2A @ 30V DC)
Communication RS485
Liquid Water, sea water, oil, alcohol, etc.
Pipe Material PVC, stainless steel, carbon steel, copper, etc.
Physical Specifications
Transmitter Die-cast aluminum, IP65, CNC machined
Transducer Encapsulated design, protection grade IP68
Double-shielded transducer cable
Standard/maximum length of cable: 30 ft / 1000 ft (9 m / 305 m)
Temperature Transmitter: -40°F ~ 140°F (-40°C ~ 60°C)
Transducer: 32°F ~ 140°F (0°C ~ 60°C) Standard
Humidity Up to 99% RH, non-condensing
Installation Methods
V Method

The "V" method is considered the standard method. It usually gives a more accurate reading and is used on pipe diameters ranging from approximately 25 mm to 400 mm (1" ~ 16"). It is convenient to use but still requires proper installation of the transducer, contact on the pipe at the pipe's centerline, and equal spacing on either side of the centerline.

Diagram of V method transducer installation showing ultrasonic signal reflecting off pipe wall

V method installation

Z Method

The signal transmitted in a "Z" method installation has less attenuation than a signal transmitted with the "V" method. This is because the "Z" method utilizes a directly transmitted (rather than reflected) signal that transverses the liquid only once. The "Z" method is able to measure on pipe diameters ranging from 100 mm to 3000 mm (4" ~ 120").

Diagram of Z method transducer installation showing ultrasonic signal passing directly through pipe

Z method installation

N Method

With the "N" method, the sound waves transverse the fluid twice and bounce three times off the pipe walls. It is suitable for small pipe diameter measurement. Measurement accuracy can be improved by extending the transit distance with the "N" method (uncommonly used).

Diagram of N method transducer installation showing ultrasonic signal bouncing multiple times through pipe

N method installation

W Method

As with the "N" method, measurement accuracy can also be improved by extending the transit distance with the "W" method. The sound wave transverses the fluid four times and bounces four times off the pipe walls. It is suitable for very small pipes (diameter less than 50 mm / 2").

Diagram of W method transducer installation showing ultrasonic signal bouncing four times through pipe

W method installation

Package & Accessory
ST505 ultrasonic flow meter package contents including transmitter, transducers, cables, and accessories

Standard package contents

Order Information
ST505 Code Specification
F Ultrasonic Flow Meter
E Ultrasonic BTU / Energy Meter (Optional)
Transducer
CT039 Insertion:
Liquid Temp.: 32°F ~ 140°F (0°C ~ 60°C) (Standard)
Cable Length
L Standard cable length: 33 ft (10 m)
L+ On request other lengths
ST505 F CT039

Complete ordering information

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Ecer Certification:

    Verified Supplier

Flo-Instruments has been specialized in the field of ultrasonic flow meters, and has over 20 years of relevant engineering and installation experience, covering clamp-on and insertion, wall-mounted and portable. We are keeping focusing on the development of industrial, commercial, and civilian ... Flo-Instruments has been specialized in the field of ultrasonic flow meters, and has over 20 years of relevant engineering and installation experience, covering clamp-on and insertion, wall-mounted and portable. We are keeping focusing on the development of industrial, commercial, and civilian ...

+ Read More

Get in touch with us

  • Reach Us
  • Flo-Instruments Co., Ltd
  • Floor 15, Building F, Bantian International Center, No.5 Huancheng South Road, Bantian Street, Longgang District, Shenzhen, 518129, China
  • https://www.flo-instruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement