| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days |
| Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measuring range | 15m, 20m, 35m |
| Power supply | Two-wire (DC24V), Four-wire(DC24V/AC220V) |
| Output signal | 4-20mA / HART |
| Frequency Range | 26Ghz |
| Temperature | -40~400℃ |
| Liquid medium | water, sea water, sewage, chemical liquids, bases, oil |
| Brand Name | KACISE |
| Model Number | KLD60 series |
| Place of Origin | CHINA |
| Certification | CE |
View Detail Information
Explore similar products
4 - 20mA Output Fluid Level Meter Hygienic Tuning Fork Densitometer Insulation
High accuracy Submersible Water Liquid Level Sensor Transmitter For power,
High Frequency Radar Fluid Level Meter Hot Water Level Sensor No Pollution
70m Measuring Range Radar Type Level Transmitter 26GHz Frequency High Accuracy
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measuring range | 15m, 20m, 35m | Power supply | Two-wire (DC24V), Four-wire(DC24V/AC220V) |
| Output signal | 4-20mA / HART | Frequency Range | 26Ghz |
| Temperature | -40~400℃ | Liquid medium | water, sea water, sewage, chemical liquids, bases, oil |
| Brand Name | KACISE | Model Number | KLD60 series |
| Place of Origin | CHINA | Certification | CE |
| High Light | ultrasonic fluid level sensor ,ultrasonic level transmitter | ||
The 6G radar level gauge is designed for liquid, paste, granule, and block material level measurement using non-contact technology. It is particularly suitable for applications with significant temperature and pressure variations, as well as environments containing inert gases and volatile substances. Utilizing microwave pulse measurement technology, this instrument operates effectively within the industrial frequency band range. The beam energy is low, allowing safe installation on various metal and non-metal containers or pipes without harm to human health or the environment.
This product employs intelligent self-tuning echo tracking technology for non-contact measurement. It features micro-fit waveguide technology design and ultra-wideband echo trace capture/emission energy regulation and control technology to ensure measurement stability and pulse conditioning. The antenna design utilizes a total gain of 23dB with a half-power beamwidth of approximately 8.5°.
| Parameter | Specification |
|---|---|
| Suitable Medium | Liquid, slightly corrosive liquid |
| Explosion-proof Grade | Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range | 20m |
| Aerials | The Rod Antenna (PP/PTFE) |
| Frequency | 6GHz |
| Temperature | (-40 ~ 130) ℃ |
| Measurement Precision | ±10mm |
| Process Pressure | (-0.1 ~ 0.3) MPa |
| Signal Output | (4 ~ 20) mA/HART |
| Scene Display | Four LCD/can be programmed |
| Power Source | Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability | ±1mm |
| Casing | Aluminum/Plastic |
| Connection | Flange (optional) / Thread |
| Parameter | Specification |
|---|---|
| Suitable Medium | Liquid, especially for corrosive liquid |
| Explosion-proof Grade | Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range | 20m |
| Aerials | The Rod Antenna (PTFE) |
| Frequency | 6GHz |
| Temperature | (-40 ~ 180) ℃ |
| Measurement Precision | ±10mm |
| Process Pressure | (-0.1 ~ 4) MPa |
| Signal Output | (4 ~ 20) mA/HART |
| Scene Display | Four LCD/can be programmed |
| Power Source | Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability | ±1mm |
| Casing | Aluminum/Plastic |
| Connection | Flange (optional) |
| Parameter | Specification |
|---|---|
| Suitable Medium | Liquid, especially with pressure and volatile liquid |
| Explosion-proof Grade | Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range | 35m |
| Aerials | The Horn Antenna |
| Frequency | 6GHz |
| Temperature | (-40 ~ 250) ℃ |
| Measurement Precision | ±10mm |
| Process Pressure | (-0.1 ~ 4) MPa |
| Signal Output | (4 ~ 20) mA/HART |
| Scene Display | Four LCD/can be programmed |
| Power Source | Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability | ±1mm |
| Casing | Aluminum/Plastic |
| Connection | Flange (optional) |
| Parameter | Specification |
|---|---|
| Suitable Medium | Solid particles or block material (not suitable for solid powder) |
| Explosion-proof Grade | Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range | 35m |
| Aerials | The Horn Antenna |
| Frequency | 6GHz |
| Temperature | (-40 ~ 250) ℃ |
| Measurement Precision | ±20mm |
| Process Pressure | (-0.1 ~ 0.1) MPa |
| Signal Output | (4 ~ 20) mA/HART |
| Scene Display | Four LCD/can be programmed |
| Power Source | Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability | ±1mm |
| Casing | Aluminum/Plastic |
| Connection | Cardan Flange (optional) |
| Parameter | Specification |
|---|---|
| Suitable Medium | Liquid, especially suitable for low dielectric constant, sticky, with mixing liquid |
| Explosion-proof Grade | Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range | 20m |
| Aerials | The Horn Antenna |
| Frequency | 6GHz |
| Temperature | (-40 ~ 400) ℃ |
| Measurement Precision | ±10mm |
| Process Pressure | (-0.1 ~ 4) MPa |
| Signal Output | (4 ~ 20) mA/HART |
| Scene Display | Four LCD/can be programmed |
| Power Source | Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability | ±1mm |
| Casing | Aluminum/Plastic |
| Connection | Flange (optional) |
| Parameter | Specification |
|---|---|
| Suitable Medium | Solid, especially suitable for high temperature conditions |
| Explosion-proof Grade | Exia IIC T6 Ga/ Exd ia IIC T6 Gb |
| Measuring Range | 15m |
| Aerials | The Horn Antenna |
| Frequency | 6GHz |
| Temperature | (-40 ~ 400) ℃ |
| Measurement Precision | ±20mm |
| Process Pressure | (-0.1 ~ 0.1) MPa |
| Signal Output | (4 ~ 20) mA/HART |
| Scene Display | Four LCD/can be programmed |
| Power Source | Two-wire (DC24V) / Four-wire (DC24V/AC220V) |
| Repeatability | ±1mm |
| Casing | Aluminum/Plastic |
| Connection | Flange (optional) |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us