| Payment Terms | L/C,T/T,Western Union,MoneyGram |
| Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days |
| Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Range | 3000mm |
| Blind zone | 150mm |
| Protection grade | IP65 (IP67 selectable) |
| Material | Plastic or Metal |
| Power Supply | 10 ... 30 V DC |
| Output | 4-20mA / 0-10V |
| Brand Name | KACISE |
| Model Number | KUS3000-M30 |
| Certification | CE |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
4 - 20mA Output Fluid Level Meter Hygienic Tuning Fork Densitometer Insulation
High accuracy Submersible Water Liquid Level Sensor Transmitter For power,
High Frequency Radar Fluid Level Meter Hot Water Level Sensor No Pollution
70m Measuring Range Radar Type Level Transmitter 26GHz Frequency High Accuracy
Product Specification
| Payment Terms | L/C,T/T,Western Union,MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Range | 3000mm | Blind zone | 150mm |
| Protection grade | IP65 (IP67 selectable) | Material | Plastic or Metal |
| Power Supply | 10 ... 30 V DC | Output | 4-20mA / 0-10V |
| Brand Name | KACISE | Model Number | KUS3000-M30 |
| Certification | CE | Place of Origin | CHINA |
| High Light | ultrasonic fluid level sensor ,ultrasonic level transmitter | ||
Ultrasonic sensor measure is a reliability and outstanding versatility measurement method. It can realize to solve the most complex projects including object detection or level measure, because its measuring way works reliably under almost all conditions.
| M18 | |
| Sensing range | 100... 1000 mm |
| Adjustment range | 100….1000mm |
| Unusable area | 0 ... 100 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx.220 kHz |
| Response delay | approx. 10 ms |
| M30-type1 | |
| Sensing range | 200... 2000 mm |
| Adjustment range | 200….2000mm |
| Unusable area | 0 ... 200 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx.150 kHz |
| Response delay | approx. 10 ms |
| M30-type2 | |
| Sensing range | 300... 3500 mm |
| Adjustment range | 300….3500mm |
| Unusable area | 0 ... 150 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx.70 kHz |
| Response delay | approx. 20 ms |
| M30-type3 | |
| Sensing range | 400... 6500 mm |
| Adjustment range | 400….6500mm |
| Unusable area | 0 ... 300 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx.50 kHz |
| Response delay | approx. 40 ms |
| LED blue | Power on |
|---|---|
| LED yellow | solid: object in the evaluation range |
| flashing: program function, object detected | |
| LED red | solid: Error |
| flashing: program function, no object detected |
| Operating voltage UB | 10 ... 30 V DC , ripple 10 %SS |
| No-load supply current I0 | ≤ 50 mA |
| Output type | 1 analog output 0-10V or 4…20mA. |
| Resolution | Evaluation range [mm]/4000, but ≥0.35mm |
| Deviation of the characteristic curve | ≤0.2% from full-scale value |
| Repeat accuracy | ± 0.1 % of full-scale value |
| Load impedance | >1k Ohm |
| Temperature influence | ≤ 2 % of full-scale value |
| Ambient temperature | -25 ... 70 °C |
| Storage temperature | -40 ... 85 °C |
| Connection type | Device connector M12 x 1 , 4-pin |
| Protection grade | IP65 (IP67 selectable) |
| Material | Housing: nickel plated brass or plastic |
| Displays in dependence on operating mode | Red LED | Yellow LED |
|---|---|---|
| TEACH-IN evaluation limit Object detected No object detected Object uncertain (TEACH-IN invalid) |
off flashes on |
flashes off off |
| Normal mode (evaluation range) | off | on |
| Fault | on | previous state |
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
Set and adjust the switching point and advance interval of the switching output and analog output products
Switching and analog output can be set using the tuning end, specifically, there are eight working modes that can be set.
Each of these Settings is divided into the following steps:
In the first step, the user selects a self-set distance or puts the sensor into the wave-loss state.
Second, connect the calibration terminal to the power supply or GND, and keep the connection until the yellow light blinks (or the red light blinks if the state is lost).
In the third step, the user selects the second self-set distance or allows the sensor to enter the wave loss state.
In the fourth step, connect the calibration terminal to the GND or power supply (different state from the second step), and keep the connection until the yellow light blinks (or the red light blinks in the case of wave loss).
There are 8 modes of switching output
About RS485 output model products. Description of
There are three modes of operation,
Click here to learn more
https://www.kacise.com/product/kus3000-m30-type1-series-ultrasonic-level-distance-sensor/?nowprocket=1Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!