China factories

China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Rigid Stem Sanitary Melt Pressure Transducer Non Toxic Material For Food Process
China Rigid Stem Sanitary Melt Pressure Transducer Non Toxic Material For Food Process

  1. China Rigid Stem Sanitary Melt Pressure Transducer Non Toxic Material For Food Process
  2. China Rigid Stem Sanitary Melt Pressure Transducer Non Toxic Material For Food Process

Rigid Stem Sanitary Melt Pressure Transducer Non Toxic Material For Food Process

  1. MOQ: 1 Piece
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal
Supply Ability 10000pcs/month
Delivery Time 5-8 working days
Packaging Details carton/wooden case, or customers requests
Range 0…3.5MPa to 0…150MPa
Output 3.33mV/V, 2.00mV/V
Accuracy ±1.0%FS, ±1.5%FS
Power supply 10VDC (6~12) VDC
Repeatability ±0.2%FS
Bridge resistance 350 ohms±10%
Overload pressure 1.5×FSO
Insulation Resistance 200MΩ @ 100Vdc
Brand Name KACISE
Model Number MPTD-5000
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal Supply Ability 10000pcs/month
Delivery Time 5-8 working days Packaging Details carton/wooden case, or customers requests
Range 0…3.5MPa to 0…150MPa Output 3.33mV/V, 2.00mV/V
Accuracy ±1.0%FS, ±1.5%FS Power supply 10VDC (6~12) VDC
Repeatability ±0.2%FS Bridge resistance 350 ohms±10%
Overload pressure 1.5×FSO Insulation Resistance 200MΩ @ 100Vdc
Brand Name KACISE Model Number MPTD-5000
Certification CE Place of Origin China
High Light high accuracy pressure sensorpiezoresistive pressure transmitter

               MPTD-5000 Melt Pressure Transducer (Sanitary) 

 

 

Description
GX MPTD-5000 series Melt Pressure Transducer(rigid stem & sanitary)can measure the pressure and temperature in one point, which can be widely used in Medicine & Food process equipment. The model 5000T is with thermocouple. Zero & span can be adjustable; with amplified signal can be connected with PLC. It has the advantages of high precision and reliable, good quality, internal 80% calibration.

 

Feature
Simple installation
High-standard quality
Stainless steel welding
80% internal calibration
Excellent stability and repeatability
Adopt environmental and non-toxic material

 

Application
Chemical fiber Equipment
Plastic and Rubber manufacturing equipment
Medicine & Food process equipment, etc
Other pressure measure and control

Specification

Parameter
Range 0…3.5MPa to 0…150MPa
Output 3.33mV/V, 2.00mV/V
Accuracy ±1.0%FS, ±1.5%FS
Power supply 10VDC (6~12) VDC
Repeatability ±0.2%FS
Bridge resistance 350 ohms±10%
Overload pressure 1.5×FSO
Internal calibration 80%±1.0%
Insulation Resistance 200MΩ @ 100Vdc
Max. Diaphragm Temp 200°C
Membrane material 15-5PH coated stainless steel
Electric connector 5PIN, 6PIN
Process connector 1/2”-20UNF, M14×1.5, M18×1.5 (Customer design)

 

Dimension

MPTD-5000

MPTD-5000T

 

Ordering Guide

 

Model Range(bar) Output Screw Thread Electric connection Other requirement
MPTD-5000(T) --- --- --- --- ---
Example: MPTD-5000-500Bar-3.33mV/V-M14×1.5-6PIN

 

Installation Precautions

Installation
The diaphragm of the sensor is the most easily damaged part, please do not drop the protective cap before installation, and in the installation should pay attention to the protection of the sensor diaphragm. The processing of mounting holes should be processed according to the technical requirements of the installation hole size and size table, to avoid the installation of the hole is not standard caused the scratch the diaphragm of the sensor and impact the sensor normal work.
Dismantle
To ensure that the installation of the hole is not left behind the metal foreign body or plastic, all sensors should be removed from the machine prior to cleaning up the extruder, the sensor can be removed only when the polymer is in a hot molten state, remove and immediately using a soft cloth to wipe the sensor probe diaphragm. Xi'an Kacise Optronics Tech Co., Ltd. can provide the installation hole of the special cleaning tool to clean up the residual material in the hole in order to facilitate the next installation.

 

Start-up
Ensure adequate heating and melting time before equipment is started, in order to ensure that all the materials in the membrane part of the sensor before the extrusion machinery work is in the melting state.

Location
The probe of the sensor can resist high temperature, But the temperature of the shell must be below 80°C, therefore, in the process of installing and using, the user must pay attention to the installation of the sensor shell part fixed in room temperature environment. The isolation of the shell and the high temperature region is beneficial to improve the measurement precision and the service life of the sensor.

Overload effect
In the process of actual pressure control, preferably within the rated pressure, although the sensor has a certain overload capacity, but the long time overload will affect the sensor's measurement accuracy and service life.

Electrical connection
In the electrical connection, the transmitter's signal output connecting cable must be connected separately through the wiring slot to avoid the interference of the scene.

Right and wrong of mounting hole size schematic diagram
Mounting Hole

Planar Sealed
D1 M18×15 M22×15 G3/8” G3/4”
D2 Φ10.2 Φ16.1 Φ10.2 Φ18.3
D3 Φ15.5 Φ20.1 Φ14.5 Φ24.2
M Φ19 Φ23 Φ17 Φ28
A 11 11 9 11
B 13 13 10 14
C 40 25 25 40
45° Slope Sealed
D1 M12×1.5 M14×1.5 1/2-20UNF M18×1.5
D2 Φ8.1 Φ8.1 Φ8.1 Φ10.2
D3 Φ10.8 Φ12.5 Φ11 Φ15.5
D4 Φ13 Φ15 Φ14 Φ19
A 6 6 6 6
B 9 9 9 11
C 16 16 16 20

 

Schematic diagram of electrical connection

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • MsEvelyn Wang
  • +86 17719566736
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement