China Digital Water Flow Sensor Circulation Pool Installation 30 - 60 L/H Velocity
China Digital Water Flow Sensor Circulation Pool Installation 30 - 60 L/H Velocity

  1. China Digital Water Flow Sensor Circulation Pool Installation 30 - 60 L/H Velocity
  2. China Digital Water Flow Sensor Circulation Pool Installation 30 - 60 L/H Velocity

Digital Water Flow Sensor Circulation Pool Installation 30 - 60 L/H Velocity

  1. MOQ: 0-100
  2. Price:
  3. Get Latest Price
Payment Terms Western Union, MoneyGram, T/T
Supply Ability 100
Delivery Time 5-8 working days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring range 0~2.000mg/L(HClO)
Accurate ±5% or ±0.05mg/L
Output RS485
Resolution 0.001mg/L
Installation Circulation pool installation
Protection level IP68
Brand Name Kacise
Model Number KBU601
Certification certificate of explosion-proof, CE
Place of Origin China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union, MoneyGram, T/T Supply Ability 100
Delivery Time 5-8 working days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring range 0~2.000mg/L(HClO) Accurate ±5% or ±0.05mg/L
Output RS485 Resolution 0.001mg/L
Installation Circulation pool installation Protection level IP68
Brand Name Kacise Model Number KBU601
Certification certificate of explosion-proof, CE Place of Origin China (Mainland)
High Light water turbidity sensoroil in water sensor

RS485 Output Residual chlorine sensor Usage Digital Output water flow sensor meter

1. Applications

 

Kacise on-line residual chlorine sensor is used to monitor the residual chlorine content continuously in drinking water treatment plant, canning plant, drinking water distribution network, swimming pool, cooling circulating water, water quality treatment project.

 

2. Feature

  • Digital sensor, RS-485 output, support MODBUS. 
  • Wide range, automatic switching measuring range.

3. Technical Specifications

 

Module No. KWS-3000
Principle the constant voltage method
Range 0~2.000mg/L(HClO)
Accurate ±5% or ±0.05mg/L
Resolution 0.001mg/L
Calibration Function Two point Calibration (Zero and Slope )
Temperature Compensation Temperature compensation automatically (Digit temperature sensor)
Working temperature 0 ~ 50℃
Output Support RS-485, MODBUS protocol
Power Supply 12~24VDC±10%
Velocity 30-60 L/h
Installation Circulation pool installation
size 30×233mm(Φ×L)
Protection IP68
Material

Polyacetal resin, PTFE, Gold, Silver

Polyformaldehyde resin, teflon, gold, silver, electro conductive rubber

 

 

4. Outline

 

 

5. Electric Connect

 

The electrode should be installed closely with the circulation pool. The electrode measurement part should be placed in the area near the circulation pool inlet. It is not allowed to face the outlet. Ensure the smooth flow . We suggest to control the flow rate within 30-60l /h to ensure the test accuracy.

Red: Power supply (12~24V)

Black: Ground(GND)

Blue: 485A

White: 485B

Exposed wire: shielded wire

Please make sure that you connect the wire correctly.

Cable specifications: the cable has a certain corrosion resistance, considering that it has been immersed in water (including seawater) or exposed to air for a long time. The diameter is Φ6 mm. Please make the waterproof processing on cable joint.

 

5. Maintenance

 

1) Sensor detection and maintenance

The new electrode and the electrode placed for a long time should be activated before use. The sensor shall be left in the tap water for 24 hours.If the returned value is not correct, please make the following operation.

  • Calibration of zero point and slope of electrode
  • Returned to the factory for inspection.

2) Calibration of sensors

a) zero point calibration: the sensor probe is placed in chlorine-free water for zero point calibration after the numerical stability.

B) slope calibration: the sensor probe is placed in the flow pool with residual chlorine standard liquid, and the slope calibration is performed after the value is stable. Suggest to use 1-2mg/L HCIO standard solution. About the preparation and determination of the standard liquid, we can refer to the determination of residual chlorine standard.

Note: the sensor has been calibrated before delivery. Since the preparation of its standard liquid has high requirements on personnel, non-professionals may not be qualified for this job. Only if the value is determined to be inaccurate, it is recommended that the user do not calibrate the sensor.

 

 

 


 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • MsEvelyn Wang
  • +86 17719566736
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement