| Payment Terms | T/T,Western Union,MoneyGram |
| Supply Ability | 1000 Pieces per Week |
| Delivery Time | 5 work days |
| Packaging Details | each unit has indicidual box and all boxes are packed in standard packages or customers requests available |
| Measurement accuracy | ± 20ppm or ±5% true value ppm |
| T90 | 30S |
| Repeatability of Zero | <±50 ppm |
| Repeatability of 50% FS | <± 2% of the measured value |
| Storage temperature | -20-80℃ |
| Life Span | 10 year |
| Operating temperature | -20-60℃ |
| Operating humidity | 0-90%RH |
| Work pressure | 0.8-1.2atm |
| Supply voltage | 12V |
| Maximum operating current | 120-150mA |
| Detection range | 50000ppm |
| Brand Name | Kacise |
| Model Number | KCS540 |
| Place of Origin | shanxi xi'an |
View Detail Information
Explore similar products
Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
KFK - G60 - TSP Factory Dust Surveillance Pro
M20*1.5 Mounting Thread Nitrogen Oxide Sensor KGD 325 For Diesel Vehicle
R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
Product Specification
| Payment Terms | T/T,Western Union,MoneyGram | Supply Ability | 1000 Pieces per Week |
| Delivery Time | 5 work days | Packaging Details | each unit has indicidual box and all boxes are packed in standard packages or customers requests available |
| Measurement accuracy | ± 20ppm or ±5% true value ppm | T90 | 30S |
| Repeatability of Zero | <±50 ppm | Repeatability of 50% FS | <± 2% of the measured value |
| Storage temperature | -20-80℃ | Life Span | 10 year |
| Operating temperature | -20-60℃ | Operating humidity | 0-90%RH |
| Work pressure | 0.8-1.2atm | Supply voltage | 12V |
| Maximum operating current | 120-150mA | Detection range | 50000ppm |
| Brand Name | Kacise | Model Number | KCS540 |
| Place of Origin | shanxi xi'an | ||
| High Light | Ir Ndir Co2 Sensor Module ,50000ppm Ndir Co2 Sensor Module ,50000ppm Carbon Dioxide Sensor Module | ||
KCS540 is a gas detection module based on the principle of NDIR infrared absorption, which is suitable for detecting the concentration of carbon dioxide in a gaseous environment at room temperature.
KCS540 adopts a patented optical cavity, imported light source and dual-channel detector to achieve dual optical path reference compensation in space. KCS540 has good selectivity, no oxygen dependence and long life.
KCS540 has UART, IEC digital output, analog voltage output and PWM frequency output mode, which is convenient for customers to choose the application; The KCS540 provides zero calibration, sensitivity calibration, and clean air calibration commands, and provides customers with a manually calibrated MCDL pin to facilitate the relative zero calibration of the sensor module using outdoor free-flowing clean air. KCS540 adopts diffusion ventilation method, which has a fast diffusion speed.
KCS540 can be widely used in HVAC fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring, can be installed in intelligent buildings, ventilation systems, robots, automobiles and other applications. It can also be applied to other confined spaces for air quality monitoring.
KCS540 diffusion exterior view
KCS540 pump suction exterior view
| parameter | symbol | minimum | Typical values | maximum | unit | |
| Storage temperature | Tstg | -20 | - | 80 | °C | |
| Operating temperature | TA | -20 | 60 | °C | ||
| Operating humidity | HA | 0 | 90 | % RH | ||
| Work pressure | PA | 0.8 | 1.2 | atm | ||
| Supply voltage | Vs | 9 | 12 | 18 | V | |
| Maximum operating current | Imax | 100 | 120 | 150 | mA | |
| Detection range | 200 | 50000 | 100% vol can be customized | ppm | ||
| Measurement accuracy | - | ± 50ppm or ±3% true value | ± 300ppm± 3% true | ppm | ||
| T90 | diffusion | - | 30 | 60 | second | |
| Repeatability | zero | <±50 | ppm | |||
| 50% FS | - | <± 2% of the measured value | - | |||
| Life Span | 3 | 10 | 15 | year | ||
Unit: mm
![]()
Diffusion
![]()
Pump-suction type
| Order information sheet | |||||
| KCS540 | KCS540 CO2 concentration sensor | ||||
| xxxx | The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm. | ||||
| 2000 | Range 200ppm (default). | ||||
| 10000 | Range 10000ppm | ||||
| 50000 | Range 50000ppm | ||||
| encode | The reaction speed is divided into two types: fast and slow | ||||
| S | Slow (default). | ||||
| Q | fast | ||||
| encode | Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering. | ||||
| Custom | Confirm the baud rate before ordering | ||||
| 2400 | 2400bps baud rate | ||||
| 9600 | 9600bps baud rate | ||||
| 19200 | 19200bps baud rate | ||||
| 38400 | 38400bps baud rate (default) | ||||
| encode | Serial port protocol | ||||
| Modbus-RTU | Standard Modbus-RTU protocol (default). | ||||
| Modbus-ASCII | Standard Modbus-ASCII protocol | ||||
| Modbus-Self | Modbus private protocol | ||||
| KCS540 | -2000 | -S | -38400 | -Modbus-RTU | |
URL: www.kacise.com
Tel: +86-29-17719566736
Email: sales@kacise.com
Address: Tangyan South Road, Xi'an City, Shaanxi Province, China
| Shorthand | Full name |
| VOL | 1% VOL refers to 1% of the volume of a particular gas in air. |
| PPM | 1PPM means that the volume of a specific gas in the air accounts for one millionth. |
| O2 | Oxygen molecules |
| LCD | LCD display |
| RS485 | Asynchronous serial port 485 |
| DC | direct current |
| AC | Communication |
| PVC | polyvinyl chloride |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!