SITRANS LCS100

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Measured variable Change in picoFarad (pF)
Alarm output 8/16 mA or 4 ... 20 mA , 2-wire loop or IO-Link, PNP, NPN
Measuring principle Capacitive level detection
Fail-safe mode Min. or max.
Switch output 4-wire relay (general purpose) or transistor (intrinsically safe)
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Brand Name SIEMENS
Model Number LCS100

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Measured variable Change in picoFarad (pF) Alarm output 8/16 mA or 4 ... 20 mA , 2-wire loop or IO-Link, PNP, NPN
Measuring principle Capacitive level detection Fail-safe mode Min. or max.
Switch output 4-wire relay (general purpose) or transistor (intrinsically safe) Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available Brand Name SIEMENS
Model Number LCS100
High Light SITRANS LCS100 water quality sensor ,industrial water quality sensor ,SITRANS LCS100 with warranty
SITRANS LCS100 Point Level Switch
SITRANS LCS100 is a versatile point level switch designed for detecting level in liquids, solids, slurries, foam, and interface applications. Its compact design makes it ideal for confined spaces, with options for plastic or stainless steel process connections and flexible rod/cable probe extensions.
SITRANS LCS100 compact model overview
7ML700.-.....-....
SITRANS LCS100 compact model side view
7ML701.-.....-....
SITRANS LCS100 extended model with rod
7ML702-.....-....
SITRANS LCS100 extended model with cable
7ML703.-.....-....
Key Benefits
  • Potted construction provides protection from shock and vibration
  • Factory calibrated to work in most applications without tuning
  • Active shield and tunable to compensate for build-up
  • Optional IO-link communication and remote testing
  • Options for plastic or stainless steel enclosure and M12 connection
Applications
SITRANS LCS100 offers flexible insertion lengths starting at 92 mm (3.6 inches) and provides versatile performance in various applications across vessels and pipes. Its advanced design ensures accurate, repeatable switchpoint performance.
The PPS probe (optional PVDF) and optional PEEK materials provide excellent chemical resistance with an operating temperature range from -40 to +125°C (-40 to +257°F). The fully potted design ensures reliability in vibrating environments like agitated tanks. When used with SensGuard protection cover, the LCS100 is protected from shearing, impact, and abrasion in demanding processes.
Available with stainless steel or polyester enclosures and stainless steel or PPS process connection options.
Key Application Areas
  • Liquids and slurries
  • Powders and granules
  • Food and pharmaceutical industries
  • Chemical processing
  • Hazardous areas
Configuration
SITRANS LCS100 configuration diagram
Technical Specifications
Specification Compact (7ML701 and 7ML700) Extended (7ML702 and 7ML703)
Measuring Principle Capacitive level detection Capacitive level detection
Measured Variable Change in picoFarad (pF) Change in picoFarad (pF)
Repeatability 2 mm (0.08 inch) 2 mm (0.08 inch)
Output Signal
Alarm output: 8/16 mA or 4...20 mA, 2-wire loop or IO-Link, PNP, NPN
Switch output: 4-wire relay (general purpose) or transistor (intrinsically safe)
Fail-safe mode: Min. or max.
Alarm output: 8/16 mA or 4...20 mA, 2-wire loop or IO-Link, PNP, NPN
*IO-Link not available with Cable version
Switch output: 4-wire relay (general purpose) or transistor (intrinsically safe)
Fail-safe mode: Min. or max.
Ambient Conditions
Location: Indoor and outdoor
Ambient temperature: -40...+85°C (-40...+185°F)
Storage temperature: -40...+80°C (-40...+176°F)
Installation category: I
Pollution degree: 4
Location: Indoor and outdoor
Ambient temperature: -40...+85°C (-40...+185°F)
Storage temperature: -40...+80°C (-40...+176°F)
Installation category: I
Pollution degree: 4
Medium Conditions
Relative dielectric constant εr: Min. 1.5
Process temperature: -40...+125°C (-40...+257°F)
Pressure (vessel): -1...25 bar (363 psi) - Stainless
-1...10 bar (146 psi) - PPS
Relative dielectric constant εr: Min. 1.5
Process temperature: -40...+125°C (-40...+257°F)
Pressure (vessel): -1...25 bar (363 psi) - Rod extensions
-1...10 bar (146 psi) - Cable extensions
Degree of Protection
Enclosure Ø65 mm: Type 4X/IP68
Enclosure Ø35 mm: Type 4X/IP68
Cable inlet: ½" NPT or M20 x 1.5
Enclosure Ø65 mm: Type 4X/IP68
Cable inlet: ½" NPT or M20 x 1.5
Sensor Length (Nominal) 92 mm (3.6 inch) 300...4,000 mm (11.8...157 inch) - Rod version
400...20,000 mm (15.7...787 inch) - Cable version
Process Connection Material Connection: 316L stainless steel or PPS; Process seal: FKM (optional FFKM); Sensor: PEEK or PPS or PVDF Connection: 316L stainless steel or PPS; Process seal: FKM (optional FFKM); Sensor: PPS or PVDF; Extension: Pipe 316L Cable: FEP jacketed
Connection (Enclosure 65 mm) Terminal block or M12 x 1 according to IEC 61076-2-101 Terminal block or M12 x 1 according to IEC 61076-2-101
Process Connection Thread: G ½", G ¾", G 1", NPT ¾"; Tri-clamp DN25 (1"), DN40 (1½"), DN50 (2"); DIN 32676 Type A and Type C; Flange DN 25, 40, 50; ASME 1", 1½", 2" Thread: G ¾", G 1", NPT ¾"; Flange DN 25, 40, 50; ASME 1", 1½", 2"; Adapters for G 1½", NPT 1¼", NPT 1½"
Power Supply
Standard:
• 4-wire with relay: 9...33 V DC
• 2-wire with 8/16 or 4...20 mA loop: 9...33 V DC
• IO-Link/PNP/NPN: 10...30 V DC
Intrinsically Safe:
• 2-wire with 8/16 or 4...20 mA loop: 10.8...30 V DC
Standard:
• 4-wire with relay: 9...33 V DC
• 2-wire with 8/16 or 4...20 mA loop: 9...33 V DC
• IO-Link/PNP/NPN: 10...30 V DC
Intrinsically Safe:
• 2-wire with 8/16 or 4...20 mA loop: 10.8...30 V DC
Certificates and Approvals
General purpose: CE, UKCA, FM, CSA
ATEX II 1G, 1/2G Ex ia IIC
ATEX II 1D, 1/2D Ex ia IIIC
IEC Ex ia IIC, IEC Ex ia IIIC
FM/CSA IS Class I, II, III, Div. 1, Groups A...G
Overfill protection: WHG (Germany) VLAREM
General purpose: CE, UKCA, FM, CSA
ATEX II 1G, 1/2G Ex ia IIC
ATEX II 1D, 1/2D Ex ia IIIC
IEC Ex ia IIC, IEC Ex ia IIIC
FM/CSA IS Class I, II, III, Div. 1, Groups A...G
Overfill protection: WHG (Germany) VLAREM
Characteristic Curves
SITRANS LCS100 temperature characteristic curve
SITRANS LCS100 pressure characteristic curve

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement