China factories

Chat Now Send Email
China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Proline Promag P 300 Electromagnetic Flowmeter for Corrosion Resistant and High
China Proline Promag P 300 Electromagnetic Flowmeter for Corrosion Resistant and High

  1. China Proline Promag P 300 Electromagnetic Flowmeter for Corrosion Resistant and High

Proline Promag P 300 Electromagnetic Flowmeter for Corrosion Resistant and High

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Hazardous area approvalsATEX, I LR approval, DNV approval, ABS approval, BV approval
Pressure approvals and certificates PED, CRN
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval
Material certificates 3.1 material
Hygienic approvals and certificates ACS, NSF 61, WRAS
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
Brand Name Endress+Hauser
Place of Origin Switzerland
Model Number Proline Promag P 300
Certification CE

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Hazardous area approvalsATEX, I LR approval, DNV approval, ABS approval, BV approval Pressure approvals and certificates PED, CRN
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval Material certificates 3.1 material
Hygienic approvals and certificates ACS, NSF 61, WRAS Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
Brand Name Endress+Hauser Place of Origin Switzerland
Model Number Proline Promag P 300 Certification CE
High Light Proline Promag P 300 flowmeterelectromagnetic flow meter with warrantyindustrial electromagnetic flow meter
Proline Promag P 300 Electromagnetic Flowmeter
Product Overview

High-temperature flowmeter for process applications with a compact, easily accessible transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

Key Specifications
Specification Details
Maximum Measurement Error Volume flow (standard): ±0.5% o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2% o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Measuring Range 4 dm³/min to 9600 m³/h (1 gal/min to 44,000 gal/min)
Medium Temperature Range Liner material PFA: -20 to +150°C (-4 to +302°F)
Liner material PFA high-temperature: -20 to +180°C (-4 to +356°F)
Liner material PTFE: -40 to +130°C (-40 to +266°F)
Maximum Process Pressure PN 40, Class 300, 20K
Nominal Diameter Range DN 15 to 600 (½ to 24")
Sensor Features
  • Diverse applications - wide variety of wetted materials
  • Energy-saving flow measurement - no pressure loss due to cross section constriction
  • Maintenance-free - no moving parts
  • Nominal diameter: max. DN 600 (24")
  • All common Ex approvals
Transmitter Features
  • Full access to process and diagnostic information
  • Numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety - freely configurable I/O functionality
  • Integrated verification - Heartbeat Technology
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Technical Details
Parameter Specification
Wetted Materials Liner: PFA; PTFE
Electrodes: 1.4435 (F316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Measured Variables Volume flow, conductivity, mass flow
Ambient Temperature Range Flange material carbon steel: -10 to +60°C (+14 to +140°F)
Flange material stainless steel: -40 to +60°C (-40 to +140°F)
Degree of Protection Standard: IP66/67, Type 4X enclosure
Power Supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Certifications & Approvals
  • Hazardous Area: ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
  • Product Safety: CE, C-tick, EAC marking
  • Functional Safety: IEC 61508, applicable per IEC 61511
  • Metrological: ISO/IEC 17025 calibration, ISO 9001:2015 compliance
  • Marine: LR, DNV, ABS, BV approvals
  • Pressure: PED, CRN
  • Material: 3.1 material certificates
  • Hygienic: ACS, NSF 61, WRAS
Measuring Principle

Electromagnetic - The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity, ensuring accurate and reliable flow measurement in demanding process applications.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement