China factories

Chat Now Send Email
China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Proline Promag D 10 electromagnetic flowmeter
China Proline Promag D 10 electromagnetic flowmeter

  1. China Proline Promag D 10 electromagnetic flowmeter

Proline Promag D 10 electromagnetic flowmeter

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Nominal diameter range DN 25 to 100 (1 to 4)
Measured variables Volume flow, mass flow
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Measuring range 9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
Max. process pressure PN 16, Class 150, 10K
Brand Name Endress+Hauser
Model Number Proline Promag D 10
Place of Origin Switzerland

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Nominal diameter range DN 25 to 100 (1 to 4) Measured variables Volume flow, mass flow
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) Measuring range 9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
Max. process pressure PN 16, Class 150, 10K Brand Name Endress+Hauser
Model Number Proline Promag D 10 Place of Origin Switzerland
High Light Proline Promag D 10 flowmeterelectromagnetic flow meter with warrantyindustrial electromagnetic flowmeter
 
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
 
Measuring range
9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
 
Medium temperature range
Liner material polyamide: 0 to +60°C (+32 to +140°F)
 
Max. process pressure
PN 16, Class 150, 10K
 
Wetted materials
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L)" "Field of application
The wafer flowmeter Promag D is designed for all basic water applications where space is at a minimum. With its straightforward hard- and software design, Promag D 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and compliant verification.
 
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
 
For basic water applications; optimized for limited space and plastic pipe installations
 
Device properties
 
Short installation length and low weight
 
Integrated ground disks made of stainless steel
 
International drinking water approvals
 
System integration with HART, Modbus RS485
 
Flexible operation with app and optional display" "Benefits
Easy, fast centering of the sensor – innovative housing construction
 
Energy-saving flow measurement – no pressure loss due to cross section constriction
 
Maintenance-free – no moving parts
 
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
 
Simple, time-saving commissioning – guided parameterization in advance and in the field
 
Integrated verification – Heartbeat Technology" "Measuring principle
Electromagnetic
 
Product headline
Highly cost-effective wafer flowmeter with easy-to-use operation concept.
For basic water applications, optimized for limited space and plastic pipe installations.
 
Sensor features
Easy, fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Short face-to-face length and low weight. Integrated ground disks made of stainless steel. International drinking water approvals.
 
Transmitter features
Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
2-line display with push buttons. Device as compact or remote version. HART.
 
Nominal diameter range
DN 25 to 100 (1 to 4)
 
Wetted materials
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L)
 
Measured variables
Volume flow, mass flow
 
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
 
Measuring range
9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
 
Max. process pressure
PN 16, Class 150, 10K
 
Medium temperature range
Liner material polyamide: 0 to +60°C (+32 to +140°F)
 
Ambient temperature range
-40 to 60°C (-40 to 140°F)
 
Sensor housing material
DN 25 to 100 (1 to 12): AlSi10Mg, coated
 
Transmitter housing material
Polycarbonat; AlSi10Mg, coated
 
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
 
Display/Operation
LCD display with touch & auto rotate
 
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
 
Digital communication
HART, MODBUS RS485
 
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
 
Hazardous area approvals
CSA, GP
 
Product safety
Product safety
 
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
 
Hygienic approvals and certificates
Hygienic approvals and certificates"

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement