| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days |
| Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Inputs | Status input |
| Digital communication | HART, Modbus RS485 |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, FM/CSA, EAC, UK Ex, KC |
| Other approvals and certificates | Other approvals and certificates |
| Product safety | CE, C-tick, EAC-marking |
| Brand Name | Endress+Hauser |
| Certification | CE |
| Place of Origin | Switzerland |
View Detail Information
Explore similar products
Panel Mounted Ultrasonic Flow Meter with Double Power Supply RS485 Communication
Split Type Ultrasonic Doppler Flow Meter with RS485 Output and Battery Powered
Wall Type Rail Mount Ultrasonic Flow Sensor with RS485 Communication and Remote
Small online Size Ultrasonic Flow Meter RTU High Accuracy For Liquid Measuring
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Inputs | Status input | Digital communication | HART, Modbus RS485 |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) | Hazardous area approvals | ATEX, FM/CSA, EAC, UK Ex, KC |
| Other approvals and certificates | Other approvals and certificates | Product safety | CE, C-tick, EAC-marking |
| Brand Name | Endress+Hauser | Certification | CE |
| Place of Origin | Switzerland | ||
| High Light | Proline Prosonic ultrasonic flowmeter ,clamp-on ultrasonic flow meter ,flowmeter with warranty | ||
"Specs at a glance
Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200
Measuring range
0 to 15 m/s (0 to 50 ft/s)
Medium temperature range
DN 15 to 65 (½to 2½""): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160""): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2"" to 24""): 150°C to 550°C (+302 to +1022 °F)
Max. process pressure
N/A" "Field of application
Prosonic Flow P 500 is the ultrasonic clamp-on flowmeter of choice for safe and maintenance-free measurement of conductive and non-conductive liquids, even in challenging applications. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
In addition, Prosonic Flow P 500 is available with:
high-temperature sensors for measurement up to 550 °C (1022 °F)
a Petroleum Application Package (PAP), calculating the standard volume for liquid hydrocarbons
Heartbeat Technology, providing continuous process transparency. This way, build-up can be detected before it affects operation " "Benefits
Flexible mounting – FlowDC reduces inlet runs to a minimum
High safety standards – Prosonic Flow P 500 is developed according to IEC 61508 functional safety requirements and holds international approvals for hazardous area, Zone 1 and Class I, Division 1
Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals, also in high-temperature applications (≤550 °C/1022 °F)
User-friendly operation – the web server offers full remote access, while the device’s touch display offers convenient on-site interaction
Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160"") " "Measuring principle
Ultrasonic flow
Product headline
Clamp-on flowmeter for limited spaces in process industries with up to 3 I/Os.
Constant accuracy even when mounted with short inlet run thanks to FlowDC.
Bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals.
Sensor features
High safety standards – SIL by design,
international hazardous area approvals. Long-term stable signal – maintenance-free
permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available.
Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160""). Medium temperature: –40 to +550 °C (–40 to +1022 °F).
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety –
freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range
Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160"")
Sensor materials
Clamp on system:
Sensor holder 1.4301/304, 1.4404/316L
Sensor housing 1.4301/304, 1.4404/316L
Strapping bands 1.4301/304, 1.4404/316L
Measured variables
Volume flow, sound velocity, flow velocity, totalizer
Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200
Measuring range
0 to 15 m/s (0 to 50 ft/s)
Max. process pressure
N/A
Medium temperature range
DN 15 to 65 (½to 2½""): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160""): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2"" to 24""): 150°C to 550°C (+302 to +1022 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
–50 to +60 °C (–58 to +140 °F) optional
Sensor housing material
N/A
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Degree of protection
Sensor remote version: IP68 type 6P
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation
4-line backlit display with touch control(operation from outside)
Optional: WLAN
Configuration via local display and operating tools possible
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs
Status input
4-20 mA input
Digital communication
HART, Modbus RS485
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX, FM/CSA, EAC, UK Ex, KC
Other approvals and certificates
Other approvals and certificates
Product safety
CE, C-tick, EAC-marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100
Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a"
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!