| Measuring range | 0.025 to 5 m/s (0.02 to 16.4 ft/s) |
| Max. process pressure | PN 25 / ASME Cl. 150 |
| Medium temperature range | 0 to 150° (17.8 to 302 °F) |
| Ambient temperature range | -20 to 60 °C (-4 to 140 °F) |
| Sensor housing material | Stainless steel |
| Transmitter housing material | Compact:AlSi10Mg, coatedStainless steel, 1.4301 |
| Brand Name | Endress+Hauser |
| Certification | CE |
| Place of Origin | Switzerland |
View Detail Information
Explore similar products
Panel Mounted Ultrasonic Flow Meter with Double Power Supply RS485 Communication
Split Type Ultrasonic Doppler Flow Meter with RS485 Output and Battery Powered
Wall Type Rail Mount Ultrasonic Flow Sensor with RS485 Communication and Remote
Small online Size Ultrasonic Flow Meter RTU High Accuracy For Liquid Measuring
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measuring range | 0.025 to 5 m/s (0.02 to 16.4 ft/s) | Max. process pressure | PN 25 / ASME Cl. 150 |
| Medium temperature range | 0 to 150° (17.8 to 302 °F) | Ambient temperature range | -20 to 60 °C (-4 to 140 °F) |
| Sensor housing material | Stainless steel | Transmitter housing material | Compact:AlSi10Mg, coatedStainless steel, 1.4301 |
| Brand Name | Endress+Hauser | Certification | CE |
| Place of Origin | Switzerland | ||
| High Light | Prosonic Flow E 100 ultrasonic flowmeter ,ultrasonic flow meter with warranty ,Proline ultrasonic flow meter | ||
"Specs at a glance
Max. measurement error
Volume flow:
- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)
Measuring range
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
Medium temperature range
0 to 150° (17.8 to 302 °F)
Max. process pressure
PN 25 / ASME Cl. 150
Wetted materials
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105" "Field of application
Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. With its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.
The measuring principle is independent of pressure, density, temperature and conductivity
Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines
Device properties:
Accuracy up to ±0.5 % (flow) or acc. to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temp.)
Process temperatures up to 150 °C (302 °F)
Entire meter housing made of stainless steel
4-20 mA HART, pulse/frequency output
Local display for reading and monitoring available
Robust transmitter housing" "Benefits
Long-term stability – reliable, robust sensor
Reducing further measuring point – multivariable device
Dependable flow measurement – high turndown (200:1)
Time-saving local operation without additional software and hardware – integrated web server
Extended calibration intervals – integrated device verification due to Heartbeat Technology
Easy commissioning – brief parameter explanations" "Measuring principle
Ultrasonic flow
Product headline
Economical Ultrasonic flowmeter with integrated temperature measurement.
Bidirectional measuring of demineralized water applications for Utilities, e.g. boiler condensate return lines.
Sensor features
Long-term stability – reliable, robust sensor. Reducing further measuring point – multivariable device. Dependable flow measurement – high turndown (200:1).
Measurement accuracy up to ±0.5 % (flow) or according to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temperature). Process temperatures up to 150 °C (302 °F). Entire meter housing made of stainless steel.
Transmitter features
Time-saving local operation without additional software and hardware – integrated web server. Extended calibration intervals – integrated device verification due to Heartbeat Technology. Easy commissioning – brief parameter explanations.
4-20 mA HART, pulse/frequency output. Local display for reading and monitoring available. Robust transmitter housing.
Nominal diameter range
DN 50 to 150 (2""to 6"")
Wetted materials
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
Measured variables
Volume flow, calculated mass flow, flow velocity, sound velocity, temperature
Max. measurement error
Volume flow:
- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)
Measuring range
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
Max. process pressure
PN 25 / ASME Cl. 150
Medium temperature range
0 to 150° (17.8 to 302 °F)
Ambient temperature range
-20 to 60 °C (-4 to 140 °F)
Sensor housing material
Stainless steel
Transmitter housing material
Compact:
AlSi10Mg, coated
Stainless steel, 1.4301
Degree of protection
Standard: IP66/67, Type 4X enclosure
With opened housing: IP20, Type 1 enclosure
Display/Operation
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs
None
Power supply
DC 19.2 to 28.8 V
Hazardous area approvals
None
Product safety
CE, C-Tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Calibration according to EN 1434 Class 2
Pressure approvals and certificates
PED
Material certificates
3.1 material"
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!