FLOWSIC550 ultrasonic flowmeter

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring principle Ultrasonic transit time difference measurement
Measured variables Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)
Measuring Medium Natural gas (dry, odorized), air
Repeatability ≤ 0.1 %
Accuracy Qmin up to Qmax ≤ ± 1 %; Accuracy class 1; typical error limits
Brand Name Endress+Hauser
Model Number FLOWSIC550
Certification CE
Place of Origin Switzerland

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring principle Ultrasonic transit time difference measurement Measured variables Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)
Measuring Medium Natural gas (dry, odorized), air Repeatability ≤ 0.1 %
Accuracy Qmin up to Qmax ≤ ± 1 %; Accuracy class 1; typical error limits Brand Name Endress+Hauser
Model Number FLOWSIC550 Certification CE
Place of Origin Switzerland
High Light FLOWSIC550 ultrasonic flow meterultrasonic flow meter with warrantyindustrial ultrasonic flow meter
"Specs at a glance
Measured variables
Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)
(*) additional function included with integrated volume correction
 
Measuring Medium
Natural gas (dry, odorized), air
 
Nominal pipe size
DN 50 (2) … DN 150 (6)" "Field of application
State-of-the-art technology for maximum measurement accuracy: The FLOWSIC550 ultrasonic compact gas flowmeter ensures highly accurate billing of low volume flows in high-pressure networks – a perfect complement to the FLOWSIC500. It is overload-proof, accurate and is monitored by an intelligent diagnostics system. FLOWSIC550 can be easily integrated into existing measuring stations. When used in transfer and measuring stations, FLOWSIC550 ensures a continuous and blockage-free gas supply.
 
Gas Measurement of low volume applications at high pressures
 
Custody transfer: gas distribution, storage, and transmission systems
 
Town border stations and city gate stations
 
 
Device properties:
 
Diagnostics and permanent operational self-monitoring
 
Durable and reliable without moving parts
 
Compact meter installations
 
Integrated volume correction
 
Battery or intrinsically safe power supply
 
Bluetooth Low Energy (BLE)" "Benefits
Ultimate measurement certainty and safety of continuous gas supply
 
Simple installation, replacement of turbine gas meters
 
Reduction of installation costs due to integrated volume correction
 
Easy Commissioning and data reading via FLOWgateTM (PC and App)
 
Minimal operating costs due to being nearly maintenance-free
 
Reliable even when the gas flow fluctuates (on/off applications)
 
Self-sufficient operation possible" "Measuring principle
Ultrasonic transit time difference measurement
 
Measured variables
Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)
(*) additional function included with integrated volume correction
 
Measuring Medium
Natural gas (dry, odorized), air
 
Repeatability
≤ 0.1 %
 
Accuracy
Qmin up to Qmax ≤ ± 1 %; Accuracy class 1; typical error limits
 
Qmin up to 0.1 Qmax ≤ ± 2 %; Accuracy class 1; maximum allowed error limits
 
0.1 Qmax up to Qmax ≤ ± 1 %; Accuracy class 1; maximum allowed error limits
After high pressure flow calibration: ±0.2 % at test pressure; otherwise ±0.5 %
 
Medium temperature range
–40 °C ... +70 °C
 
Operating pressure range
ANSI300 (ASME B16.5) ≤ 48.7 bar (g); for –40 ... +70°C
 
ANSI600 (ASME B16.5) ≤ 97.4 bar (g); for –40 ... +70°C
 
PN40 (EN 1092-1) ≤ 40 bar (g); for –40 ... +70°C
 
PN63 (EN 1092-1) ≤ 63 bar (g); for –40 ... +70°C
 
Nominal pipe size
DN 50 (2) … DN 150 (6)
 
Metrological approvals and certificates
MID: 2014/32/EU
OIML R 137-1&2:2012
EN 12405: 2010 (for integrated volume correction)
AGA 9, 2022
 
Hazardous area approvals
IECEx:
Ex ia [ia Ga] T4 IIB Gb
 
ATEX:
II 2 (1)G Ex ia [ia Ga] T4 IIB Gb
 
NEC/CEC (US/CA):
Class I Division 1, Groups C, D T4 Ex ia [ia Ga] IIB T4 Gb
Class I, Zone 1 AEx ia [ia Ga] IIB T4 Gb
 
Digital Outputs
2x Pulse and Status (HF with fmax = 2kHz, LF with fmax = 10 Hz)
 
2x RS485, external powered
 
Encoder
HF pulses + malfunction, electrically isolated (fmax = 2 kHz)
 
Encoder + LF pulses, electrically isolated (fmax = 100 Hz)
 
Encoder + HF pulses, not electrically isolated (fmax = 2 kHz)
 
2x pulses, HF and LF, electrically isolated (fmax = 2 kHz / 100 Hz)
 
Digital communication
Modbus RTU
Modbus ASCII"

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement