Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"FLOWSIC550 ultrasonic flowmeter","imgUrl":"https:\/\/img.chinax.com\/nimg\/3d\/16\/e80d78e2193e41b5554b5834be45-200x200-1\/flowsic550_ultrasonic_flowmeter.jpg","attrs":{"Measured variables":"Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)","Measuring Medium":"Natural gas (dry, odorized), air","Measuring principle":"Ultrasonic transit time difference measurement","Brand Name":"Endress+Hauser"}}
{"title":"Panel Mounted Ultrasonic Flow Meter with Double Power Supply RS485 Communication","imgUrl":"https:\/\/img.chinax.com\/nimg\/6f\/21\/8ba68abbcb0cd7d06388802e38fe-200x200-1\/panel_mounted_ultrasonic_flow_meter_with_double_power_supply_rs485_communication.jpg","attrs":{"Pipe material":"Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed","Communication":"RS485","Pipe Diameter":"15~6000mm","Temperature":"-30~160\u2103"}}
{"title":"Split Type Ultrasonic Doppler Flow Meter with RS485 Output and Battery Powered","imgUrl":"https:\/\/img.chinax.com\/nimg\/2b\/c1\/b395ef7e61a8e27eb1038e5a1f89-200x200-1\/split_type_ultrasonic_doppler_flow_meter_with_rs485_output_and_battery_powered_for_0_02m_ef_bd_9e10_00m_water_depth_measurement.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KDF1000","Certification":"CE","Place of Origin":"China"}}
{"title":"Wall Type Rail Mount Ultrasonic Flow Sensor with RS485 Communication and Remote","imgUrl":"https:\/\/img.chinax.com\/nimg\/21\/f0\/5b7f51c1da7cbfab7256117009ec-200x200-1\/wall_type_rail_mount_ultrasonic_flow_sensor_with_rs485_communication_and_remote_control.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KUFS2000A Series","Certification":"CE","Place of Origin":"China"}}
{"title":"Small online Size Ultrasonic Flow Meter RTU High Accuracy For Liquid Measuring","imgUrl":"https:\/\/img.chinax.com\/nimg\/8e\/7c\/c101e68a495ff29ccb2575b705e2-200x200-1\/small_online_size_ultrasonic_flow_meter_rtu_high_accuracy_for_liquid_measuring.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KUFH2000","Certification":"CE","Place of Origin":"China"}}
{"title":"Rechargeable Battery Portable Ultrasonic Flow Meter For Routing Inspection","imgUrl":"https:\/\/img.chinax.com\/nimg\/9a\/c3\/8a9258e8767bec63e22360a5aec0-200x200-1\/rechargeable_battery_portable_ultrasonic_flow_meter_for_routing_inspection.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KUFH2000A","Certification":"CE","Place of Origin":"China"}}
{"title":"Clamp On Handheld Ultrasonic Flow Meter No Pipe Cutting With Built In Printer","imgUrl":"https:\/\/img.chinax.com\/nimg\/e5\/ed\/63ffe2872ac42adbe296ff4abac5-200x200-1\/clamp_on_handheld_ultrasonic_flow_meter_no_pipe_cutting_with_built_in_printer.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KUFP2000","Certification":"CE","Place of Origin":"China"}}
State-of-the-art technology for maximum measurement accuracy: The FLOWSIC550 ultrasonic compact gas flowmeter ensures highly accurate billing of low volume flows in high-pressure networks - a perfect complement to the FLOWSIC500.
Field of Application
This overload-proof, accurate flowmeter is monitored by an intelligent diagnostics system and can be easily integrated into existing measuring stations. When used in transfer and measuring stations, FLOWSIC550 ensures a continuous and blockage-free gas supply.
Gas measurement of low volume applications at high pressures
Custody transfer: gas distribution, storage, and transmission systems
Town border stations and city gate stations
Key Benefits
Ultimate measurement certainty and safety of continuous gas supply
Simple installation, replacement of turbine gas meters
Reduction of installation costs due to integrated volume correction
Easy commissioning and data reading via FLOWgate™ (PC and App)
Minimal operating costs due to being nearly maintenance-free
Reliable even when the gas flow fluctuates (on/off applications)
Self-sufficient operation possible
Device Properties
Diagnostics and permanent operational self-monitoring
Durable and reliable without moving parts
Compact meter installations
Integrated volume correction
Battery or intrinsically safe power supply
Bluetooth Low Energy (BLE)
Technical Specifications
Measuring Principle
Ultrasonic transit time difference measurement
Measured Variables
Volume a.c., volumetric flow a.c., gas velocity, volume s.c. (*), volume flow under s.c. (*) (*) additional function included with integrated volume correction
Measuring Medium
Natural gas (dry, odorized), air
Repeatability
≤ 0.1 %
Accuracy
Qmin up to Qmax ≤ ± 1 %; Accuracy class 1; typical error limits
Qmin up to 0.1 Qmax ≤ ± 2 %; Accuracy class 1; maximum allowed error limits
0.1 Qmax up to Qmax ≤ ± 1 %; Accuracy class 1; maximum allowed error limits
After high pressure flow calibration: ±0.2 % at test pressure; otherwise ±0.5 %
Medium Temperature Range
-40 °C ... +70 °C
Nominal Pipe Size
DN 50 (2) … DN 150 (6)
Operating Pressure Ranges
ANSI300 (ASME B16.5)
≤ 48.7 bar (g); for -40 ... +70°C
ANSI600 (ASME B16.5)
≤ 97.4 bar (g); for -40 ... +70°C
PN40 (EN 1092-1)
≤ 40 bar (g); for -40 ... +70°C
PN63 (EN 1092-1)
≤ 63 bar (g); for -40 ... +70°C
Metrological Approvals and Certificates
MID: 2014/32/EU
OIML R 137-1&2:2012
EN 12405: 2010 (for integrated volume correction)
AGA 9, 2022
Hazardous Area Approvals
IECEx: Ex ia [ia Ga] T4 IIB Gb
ATEX: II 2 (1)G Ex ia [ia Ga] T4 IIB Gb
NEC/CEC (US/CA): Class I Division 1, Groups C, D T4 Ex ia [ia Ga] IIB T4 Gb
Class I, Zone 1 AEx ia [ia Ga] IIB T4 Gb
Digital Outputs
2x Pulse and Status (HF with fmax = 2kHz, LF with fmax = 10 Hz)
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .
We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .
We have been specializing...