| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days |
| Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measuring principle | Ultrasonic transit time difference measurement |
| Measured variables | Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC) |
| Measuring Medium | Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2 |
| Repeatability | ≤ 0.05 % of the measured value (typical) |
| Medium temperature range | –46 °C ... +180 °C / -51 °F ... +356 °F |
| Operating pressure range | 0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g) |
| Brand Name | Endress+Hauser |
| Model Number | FLOWSIC600-XT |
| Place of Origin | Switzerland |
View Detail Information
Explore similar products
Panel Mounted Ultrasonic Flow Meter with Double Power Supply RS485 Communication
Split Type Ultrasonic Doppler Flow Meter with RS485 Output and Battery Powered
Wall Type Rail Mount Ultrasonic Flow Sensor with RS485 Communication and Remote
Small online Size Ultrasonic Flow Meter RTU High Accuracy For Liquid Measuring
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measuring principle | Ultrasonic transit time difference measurement | Measured variables | Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC) |
| Measuring Medium | Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2 | Repeatability | ≤ 0.05 % of the measured value (typical) |
| Medium temperature range | –46 °C ... +180 °C / -51 °F ... +356 °F | Operating pressure range | 0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g) |
| Brand Name | Endress+Hauser | Model Number | FLOWSIC600-XT |
| Place of Origin | Switzerland | ||
| High Light | FLOWSIC600-XT ultrasonic flow meter ,industrial ultrasonic flowmeter ,high-precision ultrasonic flow meter | ||
The FLOWSIC600-XT is a high-precision ultrasonic flowmeter designed for demanding industrial applications, featuring advanced diagnostic capabilities and exceptional measurement accuracy.
| Measured Variables | Volumetric flow a.c., volume a.c., gas velocity, speed of sound, optional volume correction via integrated electronic volume corrector (EVC) |
|---|---|
| Measuring Medium | Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO₂, N₂, H₂S, O₂, H₂ |
| Nominal Pipe Size | 3″ ... 56″ (DN 80 ... DN 1400), other nominal pipe sizes on request |
| Repeatability | ≤ 0.05% of the measured value (typical) |
| Accuracy |
4-path and 8-path version ≤ ±0.5% | (≤ ±1%) Dry-calibrated 4-path and 8-path version ≤ ±0.2% | (≤ ±0.5%) After flow calibration and alignment using constant factor 4-path and 8-path version ≤ ±0.1% | (≤ ±0.2%) After flow calibration and alignment using polynomial or piecewise correction |
| Medium Temperature Range | -46°C ... +180°C / -51°F ... +356°F (On request: -194°C ... +280°C / -381°F ... +536°F) |
| Operating Pressure Range | 0 bar (g) ... 450 bar (g) / 0 psi (g) ... 6527 psi (g) |
Ultrasonic transit time difference measurement
IECEx: Ex db ia op is [ia Ga] IIA/IIC T4 Gb, Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb, Ex ia op is IIA/IIC T4 Ga
ATEX: II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb, II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb, II 1G Ex ia op is IIA/IIC T4 Ga
NEC/CEC (US/CA): Various explosion-proof and intrinsically safe certifications for Class I, Division 1 and Zone 0/1 applications
Digital Outputs: 4 outputs (2 x status, 2 x pulse): ≤ 30 V, 50 mA, passive, electrically isolated, open collector or conforming to NAMUR (DIN EN 60947-5-6), fmax = 10 kHz (scalable)
Digital Communication: Modbus TCP
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...