China factories

Chat Now Send Email
China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China FLOWSIC100 Flare-XT ultrasonic flow measurement instrument
China FLOWSIC100 Flare-XT ultrasonic flow measurement instrument

  1. China FLOWSIC100 Flare-XT ultrasonic flow measurement instrument

FLOWSIC100 Flare-XT ultrasonic flow measurement instrument

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring principle Ultrasonic transit time difference measurement
Measured variables Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
Measuring range 0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
Nominal pipe size 1-path measurement 4 ″ ... 86 ″
Digital communication HART
Brand Name Endress+Hauser
Model Number FLOWSIC100
Certification CE
Place of Origin Switzerland

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring principle Ultrasonic transit time difference measurement Measured variables Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
Measuring range 0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s) Nominal pipe size 1-path measurement 4 ″ ... 86 ″
Digital communication HART Brand Name Endress+Hauser
Model Number FLOWSIC100 Certification CE
Place of Origin Switzerland
High Light FLOWSIC100 ultrasonic flow meterFlare-XT flow measurement instrumentultrasonic flow meter with warranty
"Specs at a glance
Measured variables
Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
 
Measuring range
0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
 
Conformities
ATEX: 2014/34/EU
EMC: 2014/30/EU
RoHS: 2011/65/EU
PED: 2014/68/EU" "Field of application
Detection of flare gas leaks, steam flow measurement, monitoring of gas losses, monitoring of steam injection in flare gas burning as well as process optimization are fields of use for this gas flowmeter FLOWSIC100-Flare-XT. It measures values such as gas velocity, gas volume, mass flow rate, molecular weight, volumetric flow and sound velocity. Additionally, it provides an intelligent device monitoring process and supports predictive maintenance - designed for current and future challenges.
 
Flare gas measurement for the production and processing of natural gas and associated petroleum gases (APG)
 
Flare gas measurement in chemical and petrochemical plants
 
Measurement of LNG boil-off gas
 
 
Device properties:
 
Reliable measurement even at high gas velocities and with changing gas compositions
 
Direct mass flow calculation without additional gas analyzers
 
Intuitive FLOWgateTM software for commissioning, operation and diagnostics
 
Self monitoring, self testing and predictive maintenance" "Benefits
Several standards and guidelines for flare gas measurement are observed
 
Maximum plant availability
 
Compatible with current and future communication architectures
 
Independent maintenance through verification on demand and support when required
 
Easy replacement of existing measurement systems, with suitable retrofit or upgrade solutions available" "Measuring principle
Ultrasonic transit time difference measurement
 
Measured variables
Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
 
Measuring range
0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
 
Max. Measurement error
Volumetric flow, a. c.; 1 % ... 5 %
Related to the measured value with ultrasonic technology (in the range ≥ 0.3 m/s (≥ 1 ft/s) to measuring range end value)
0,5 % ... 1,5 % with spool piece and flow calibration
Related to the measured value with ultrasonic technology (in the range ≥ 1.0 m/s (≥ 3.3 ft/s) to calibration range end value
 
Mass flow rate a.c.; 2 % ... 5.5 %
Related to the measured value with ultrasonic technology (in the range ≥ 0.3 m/s (≥ 1 ft/s) to measuring range end value)
1,5 % ... 2 % with spool piece and flow calibration
Related to the measured value with ultrasonic technology (in the range ≥ 1 m/s (≥ 3.3 ft/s) to calibration range end value)
 
Medium temperature range
-196 °C ... +280 °C
(-320 °F ... +536 °F)
 
Operating pressure range
CL150 device flange (1) ATEX/IECEx: 20 bar(g)
CSA: 16 bar(g)
PN25 device flange (optional) (1) ATEX/IECEx: 20 bar(g)
CSA: 16 bar(g)
CL300 device flange (optional) (1) ATEX/IECEx: 20 bar(g)
CSA: 16 bar(g)
(1) Temperature dependent.
 
Nominal pipe size
1-path measurement 4 ″ ... 86 ″
2-path measurement 12 ″ ... 86 ″
Other nominal sizes on request
 
Conformities
ATEX: 2014/34/EU
EMC: 2014/30/EU
RoHS: 2011/65/EU
PED: 2014/68/EU
 
Hazardous area approvals
Interface Unit
IECEx:
Zone 1: Ex db eb ia IIC T4 Gb
Zone 1: Ex db ia IIC T4 Gb
Zone 2: EX ec ia IIC T4 Gc
 
ATEX:
Zone 1: II 2G Ex db eb ia IIC T4 Gb
Zone 1: II 2G Ex db ia IIC T4 Gb
Zone 2: II 3G Ex ec ia IIC T4 Gc
 
NEC/CEC (US/CA):
Class I, Zone 1, AEx d ia IIC T4 Gb
Class I, Division 1, Groups B, C, D, T4
Class I, Zone 2, AEx ec ia IIC T4 Gc
Class I, Division 2, Group A, B, C and D, T4
 
Sensors
F1F-S/P/R:
IECEx:
Zone 1: Ex db [ia Ga] IIC T6 Ga/Gb
ATEX:
Zone 1: II 1/2 G Ex db [ia Ga] IIC T6 Ga/Gb
NEC/CEC (US/CA):
Class I, Division 1, Groups B, C and D, T4;
Class I, Zone 1, Ex/AEx d[ia] IIB + H2, T4;
 
F1F-M:
IECEx:
Zone 1: Ex db [ia Ga] IIB T4 Ga/Gb
ATEX:
Zone 1: II 1/2 G Ex db [ia Ga] IIB T4 Ga/Gb
NEC/CEC (US/CA):
Class I, Division 1, Groups C and D, T4;
Class I, Zone 1, Ex/AEx d[ia] IIB, T4;
 
F1F-H:
IECEx:
Zone 1: Ex db IIC T6 Gb
ATEX:
Zone 1: II 2 G Ex db IIC T6 Gb
NEC/CEC (US/CA):
Class I, Division 1, Groups B, C and D, T4;
Class I, Zone 1, Ex/AEx d IIB + H2, T4;
 
Outputs
Up to 6 outputs when using I/O modules (Option)
16 bit:
4 ... 20 mA
7 V DC ... 30 V DC
In accordance with NAMUR NE43
Passive, galvanically isolated
Reverse polarity protection
 
Digital Outputs
Switching output:
Up to 6 outputs when using I/O module (option)
Electrically isolated
Max. current: 70 mA
Max. switching frequency: 50 Hz
Max. input voltage: 30 V DC
Max. saturation voltage at output: 0.5 V DC
Switchable Namur/open collector
Reverse polarity protection
 
Digital output/Frequency output:
Up to 12 digital outputs when using I/O modules (option)
Electrically isolated
Max. current: 50 mA
Max. switching frequency: 10 kHz
Max. input voltage: 30 V DC
Max. saturation voltage at output: 1.8 V DC
Switchable Namur/open collector
Reverse polarity protection
 
Digital communication
HART
MODBUS
FOUNDATION FIELDBUS"

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement