China factories

Chat Now Send Email
China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Surface Scattering Light Turbidity Detector TB830D with 0-2000 NTU Range and LED
China Surface Scattering Light Turbidity Detector TB830D with 0-2000 NTU Range and LED

  1. China Surface Scattering Light Turbidity Detector TB830D with 0-2000 NTU Range and LED

Surface Scattering Light Turbidity Detector TB830D with 0-2000 NTU Range and LED

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring method Surface scattering method
Measuring Range (Turbidity standard: Formazin) 0-2 to 0-2000 NTU
Temperature 0 to 50°C
Flow Rate 1.5 to 2 L/min
Pressure 500 kPa max
Brand Name Yokogawa
Model Number TB830D

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring method Surface scattering method Measuring Range (Turbidity standard: Formazin) 0-2 to 0-2000 NTU
Temperature 0 to 50°C Flow Rate 1.5 to 2 L/min
Pressure 500 kPa max Brand Name Yokogawa
Model Number TB830D
High Light 0-2000 NTU range Turbidity DetectorSurface scattering method Turbidity AnalyzerLED light source Water Quality Sensor
Surface Scattering Light Turbidity Detector TB830D
Digital Solution for Water Quality Analysis
Reduce Maintenance with Advanced Technology
Many of our customers face operational challenges - Yokogawa Turbidity Analyzers TB800 series provide reliable solutions.
Yokogawa's turbidity meters have been developed and improved to suit various applications in water treatment plant turbidity measurement. As a result, we have accumulated many achievements and gained the trust of our customers since our first product was launched in 1959.
The TB830D is part of the SENCOM4.0 platform family and can connect to FLXA402T. Thanks to a smart unit equipped detector, TB830D provides enhanced operational insight.
The TB830D is a turbidity analyzer equipped with LEDs as the light source, offering dirt-resistant design, reliable measurements, and reduced operational expenses through advanced diagnostic functions.
*Based on a Yokogawa survey in 2019
Advanced Measurement Technology
Less Susceptible to Contamination Due to Non-Contact Design
Compatible with Various Applications
  • Surface scattering measurement method minimizes contamination
  • LED light source for 3-year long life and reduced maintenance costs
  • High sensitivity and high accuracy with long-standing reliability
  • Good linearity and reproducibility
  • Measuring range from 0-2 NTU to 0-2000 NTU
  • Improved cleaning system reduces maintenance
  • Easy-to-clean cell structure (by GS)
Multi-sensor input diagram showing connectivity options for turbidity, chlorine, pH and conductivity sensors
Multi-sensor Input: Not only Turbidity Detector but also Chlorine Sensor Unit, pH sensor and conductivity sensor are connectable to one transmitter.
TB830D turbidity analyzer unit overview
Applications
Turbidity Measurement for Tap Water, Sewage, River Water and General Process Water
Water Purification Treatment
  • Sedimentation
  • Flocculation
  • Settling Basins
  • Clean water reservoir
  • Distributing pump
  • Distribution tank & Piping
Wastewater Treatment
  • Discharge/Reuse
Water treatment process application diagram
Specifications
Measuring method Surface scattering method
Measuring Range
(Turbidity standard: Formazin)
0-2 to 0-2000 NTU
Sample Conditions Temperature: 0 to 50°C
Flow Rate: 1.5 to 2 L/min
Pressure: 500 kPa max
Power Supply 100 to 240 V DC, 50/60 Hz
Digital Communication Modbus TCP/IP, Modbus RTU
Installation Indoor (Outdoor use requires protection against rain. Direct sunlight must be avoided.)
Cleaning system Automatic wash
Performance
Linearity 0-1000 NTU: ±2% of reading or ±0.04 NTU whichever is greater
Over 1000 NTU: ±4% of reading
Repeatability ±1% of reading or ±0.02 NTU whichever is greater

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement