China factories

Chat Now Send Email
China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Inductive Conductivity Sensor ISC40 with Wide Measuring Range Maintenance Free
China Inductive Conductivity Sensor ISC40 with Wide Measuring Range Maintenance Free

  1. China Inductive Conductivity Sensor ISC40 with Wide Measuring Range Maintenance Free

Inductive Conductivity Sensor ISC40 with Wide Measuring Range Maintenance Free

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms MoneyGram,Western Union,T/T,D/P,L/C,D/A
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring range: 1 µS/cm to 1999 mS/cm
Output span Min. 100 µS/cm ; Max. 1999 mS/cm
Process temperature -10 to 130°C for continuous exposure
Brand Name Yokogawa
Model Number Sensor ISC40

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms MoneyGram,Western Union,T/T,D/P,L/C,D/A Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring range: 1 µS/cm to 1999 mS/cm Output span Min. 100 µS/cm ; Max. 1999 mS/cm
Process temperature -10 to 130°C for continuous exposure Brand Name Yokogawa
Model Number Sensor ISC40
High Light Wide Measuring Range Inductive Conductivity SensorMaintenance Free Toroidal Conductivity SensorCorrosion Resistant Electrodeless Conductivity Sensor

There are two basic sensor styles used for measuring Conductivity: Contacting and Inductive (Toroidal, Electrodeless).

With Inductive Conductivity (also called Toroidal or Electrodeless), the sensing elements (electrode coils) of an inductive sensor do not come in direct contact with the process. These two matched (identical) coils are encapsulated in PEEK (or Teflon) protecting them from the adverse effects of the process.

There is only one cell factor (constant) for the ISC40 Inductive Sensor. It covers nearly the entire conductivity measurement range ~ 50-2,000,000 µS/cm. Only on the low end (below 50 µS) does the accuracy of the sensor suffer.

The ISC40 Inductive sensor is virtually maintenance free.

Depending on your region there is either an ISC40G/ISC40S series or ISC40GJ/ISC40SJ series offered. 


The accuracy is 0.5% of reading plus 0.5 microS/cm for any conductivity value, whether measured in rinse water or in concentrated acids. The materials of construction ensure a long life under harsh industrial conditions.

The erosion/abrasion resistant PEEK (Poly Ether Ether Ketone), which also features excellent chemical resistance in all solutions except fluoric acid or oxidizing concentrated acids. The ultimate material in terms of chemical resistance is the PFA (Teflon) for applications in hydrofluoric acid and oxidizing concentrated acids (nitric, sulfuric, oleum).

The ISC40G and ISC40s are available in PEEK (sensor type GG) for general use. In applications where sample is aggressive to Peek we offer the sensor in Teflon (Sensor type TG).

The ISC40 sensor is provided with a rugged Stainless Steel mounting thread, nut and gasket combination for ultimate flexibility in installation using bulk head installation technique. There is also a wide range of holders and options available for reliable in-line or off-line installation with double O-ring seals for long service life of the sensor. Additional models are available for use in Ball-Valve Insertion applications and in Sanitary Flange installations.

Both sensors have a large bore for optimal resistance to fouling processes and when properly installed, the flow will keep the sensor clean preventing measuring errors.

  • Inductive Conductivity technique for elimination of fouling and polarization errors.
  • Wide bore sensors for long term stability.
  • Installation flexibility by wide range of holders and by the use of universal bulkhead construction.
  • Wide rangeability in terms of conductivity (1 μS/cm to 2 S/cm) and temperature (-20 to 130ºC).
  • All applications where severe electrode fouling prevents the use of contacting electrodes.
  • All ranges except the (ultra) pure water applications.
  • All slurry applications where conventional systems suffer from plugging or erosion.

Depending on your region there are different versions of the holders available. 

ISC40FF/ISC40FS/ISC40FD Holders 

This program includes flow fittings and their subassemblies for in-line or direct mounting of conductivity sensors in piping systems. A wide choice of construction materials gives the user the best solution for any process considering chemical resistance, pressure and temperature specifications.

  • Wide choice of construction materials.
  • High degree of standardization to all cells.
  • Easy mounting, service and removal or replacement of sensors.
  • Electrolitically polished stainless steel designs for optimal corrosion resistance.
  • Available with flange adapters.

Model PR10 Retractable "Hot-Tap" Holder

On-line measurements often present extra challenges, especially when routine maintenance is required. The PR10 is ideally suitable for applications where the sensors must be removed without interrupting or shutting down the process. Without any special tools the PR10 can be retracted safely from the process at pressures up to 5 bar (72 psi). The PR10 is a universal retractable assembly that can be used for all liquid measurements. The PR10 is designed to accept any commercially available pH/ORP or dissolved oxygen sensor that has a PG13.5 connection while still being backwards compatible with old Yokogawa electrodes.

For ease of use optional flush ports are available. In the retracted position the sensor can be kept moist, cleaned or even calibrated. This can all be done without process interruption or disassembly of the armature.

  •  One model for pH/ORP, dissolved oxygen, conductivity and inductive conductivity sensors
  • All commercially available pH electrodes, such as PG13.5, SMART sensors, Vario Pin, YEF and DIN connectors can be installed in the PR10.
  • Integrated protection cage
  • A "scraper" is built-in to each assembly to effectively scrape or wipe off the
    process from the PR10's shaft as it is being retracted from the process.
  • A safe "through the valve" insertion and retraction design
  • Simplified installation by optional ball valves with flanged or tapered connections
  • Optional flush port accessories makes it easy to keep sensors moist (pH) and clean, and also provides access for calibration if desired.

ISC40J Inductive 
Conductivity SensorCompatibility: ISC40GJ is compatible with FLXA202/FLXA21 2-Wire Liquid Analyzer, FLXA402 4-Wire Converter and ISC450G 4-wire Inductive Conductivity Converter.
Transmitter:
Measuring range: 1 µS/cm to 1999 mS/cm
Output span: Min. 100 µS/cm ; 
Max. 1999 mS/cm
Process temperature: -10 to 130°C for continuous exposure
Suitable for steam-sterilizable applications. (Note 1 and 2)
Process Pressure: Pressure resistance 2 MPa max. (Note 1)
Note 1: The process temperature and pressure differ depending upon the adapter or holder used.
Note 2: The temperature compensation range of the transmitter is between -10 and 130°C.
Process flow: Max. 5 m/s
Wetted materials:
Sensor: PEEK (polyether ether ketone)
O-ring: Fluoro-rubber (FKM) or ethylene propylene rubber
Adapter (additional machining): Stainless steel (316 SS), PVC or PVDF
Non-wetted materials:
Sensor Screws: Stainless steel (304 SS).
Retaining Nuts: Stainless steel (304 SS).
Cables: Weatherproof vinyl
Process connection: With retaining nut on G3/4 bulkhead of sensor top (refer to section, [2.3] External Dimensions') for bulkhead mounting:optional process fittings.
Process Adapter: 
JIS 10K 50 RF flange (Material: Stainless steel (316 SS))
JIS 10K 50 FF flange (Material: PVC or PVDF)
DIN PN16 DN50 flange
ANSI Class150 2" flange
R2 screw-in adapter
Cable Length: 5 m, 10 m, 15 m, 20 mExtension cable of up to 50 m can be used. (sensor cable and extension cable)
Weight: Sensor Approx. 0.6 kg

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement