China 316 Stainless Steel 2-Electrode Conductivity Sensor with Pt1000 Temperature
China 316 Stainless Steel 2-Electrode Conductivity Sensor with Pt1000 Temperature

  1. China 316 Stainless Steel 2-Electrode Conductivity Sensor with Pt1000 Temperature

316 Stainless Steel 2-Electrode Conductivity Sensor with Pt1000 Temperature

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Materials Of Construction 316 Stainless Steel or Titanium
Design Sytle 2-Electrode
Temperature Element Pt1000
Brand Name Yokogawa
Model Number SC42/SC4A(J)

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms MoneyGram,Western Union,T/T,D/P,D/A,L/C Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Materials Of Construction 316 Stainless Steel or Titanium Design Sytle 2-Electrode
Temperature Element Pt1000 Brand Name Yokogawa
Model Number SC42/SC4A(J)
High Light 10 bar/142 PSIG Conductivity Sensor150°C/302°F Water Quality Sensor7 bar/100 PSIG Contacting Sensor
Contacting Conductivity Sensors SC42/SC4A(J)
Why Measure Conductivity?

Conductivity serves as an economical, low-maintenance indicator of water quality. High-quality water with minimal contaminants exhibits low conductivity. Compared to pH measurement, conductivity requires far less maintenance and minimal calibration. Common applications include boiler feedwater, reverse osmosis (RO), and demineralizer systems.

Since conductivity increases with ion concentration (up to a point), it can correlate to percentage concentration values for solutions such as acids or bases. However, as conductivity is non-specific, percentage concentration measurement is only applicable to individual chemicals, not mixtures of multiple contributing chemicals.

Measurement Principles

Two primary sensor styles are used for conductivity measurement: Contacting and Inductive (Toroidal, Electrodeless).

Contacting sensors measure conductivity by applying an alternating electrical current to sensor electrodes (which together define the cell constant) immersed in a solution and measuring the resulting voltage. The solution acts as the electrical conductor between the sensor electrodes.

Factors Affecting Accuracy
  • Polarization: Can influence measurement accuracy
  • Contamination: Deposits or coatings on electrode surfaces of 2-pole cells can lower conductivity readings. These effects can be prevented with 4-pole conductivity cells.
  • Cable Resistance: Can introduce measurement errors and must be accounted for
  • Temperature: Conductivity measurements are temperature-dependent, with conductivity increasing as temperature rises
Product Selection
Model Code SC42 Large Bore SC4A(J) SC42 Small Bore
Cell Constants 0.01/cm; 0.1/cm; 1.0/cm 0.02/cm; 0.1/cm 0.02/cm; 0.1/cm; 1.0/cm
Ranges 0.02-2,000 µS/cm; 0.2-20,000 µS/cm; 2.0-200,000 µS/cm 0.04-400 µS/cm; 0.2-2,000 µS/cm 0.04-400 µS/cm; 0.4-2,000 µS/cm; 4.0-5,000 µ/cm
Temperature Element Pt1000 Pt1000 Pt1000
Pressure Rating 10 bar/142 PSIG 10 bar/142 PSIG 7 bar/100 PSIG
Maximum Temperature 150°C/302°F 110°C/230°F 100°C/212°F
Installation Connections Requires FD40, FS40 or FF40 Holder 3/4" NPT Fitting; 1", 1.5" or 2" Tri-Clamp; Retractable 3/4" NPT Fitting; 1", 1.5" or 2" Tri-Clamp
Integral Cable NO YES YES
Materials Of Construction 316 Stainless Steel 316 Stainless Steel or Titanium 316 Stainless Steel or Titanium
Design Style 2-Electrode 2-Electrode 2-Electrode

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement