China factories

Chat Now Send Email
China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Customizable 0-20% VOL Methane Air Sensor Module with Peak Current 210mA for
China Customizable 0-20% VOL Methane Air Sensor Module with Peak Current 210mA for

  1. China Customizable 0-20% VOL Methane Air Sensor Module with Peak Current 210mA for
  2. China Customizable 0-20% VOL Methane Air Sensor Module with Peak Current 210mA for

Customizable 0-20% VOL Methane Air Sensor Module with Peak Current 210mA for

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T,Western Union,MoneyGram
Supply Ability 1000 Pieces per Week
Delivery Time 5-8 working days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Operating humidity 0 ~ 99% RH (condensation)
Response time T90<15s
Product weight 255g
Peak current <210mA
Measuring principle TD-LAS
Lower detection limit 0.2% VOL
Measuring range 0-20% VOL (customizable)
Minimum resolution 0.01% VOL
Brand Name Kacise
Model Number TDLAS103
Place of Origin China (Mainland)
Certification certificate of explosion-proof, CE

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,Western Union,MoneyGram Supply Ability 1000 Pieces per Week
Delivery Time 5-8 working days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Operating humidity 0 ~ 99% RH (condensation) Response time T90<15s
Product weight 255g Peak current <210mA
Measuring principle TD-LAS Lower detection limit 0.2% VOL
Measuring range 0-20% VOL (customizable) Minimum resolution 0.01% VOL
Brand Name Kacise Model Number TDLAS103
Place of Origin China (Mainland) Certification certificate of explosion-proof, CE
High Light 20% VOL Methane Air Sensor ModuleCustomizable Methane Air Sensor Module
Introduction

Utilizing TD-LAS technology, the 3.3V methane sensor detects methane through its unique absorption spectrum using a 1653.7nm laser, with resistance to interference from water vapor and other gases. Combining direct absorption with wavelength modulation, it features an "N" type optical path structure for extended absorption and high precision. Equipped with low-temperature laser components and a temperature correction algorithm, the sensor performs well across various environments. The standard communication protocol and threaded interface increase its compatibility, making it ideal for methane leak detection and alarms in industries like catering, chemical, and coal mining.

Feature
  • High detection accuracy
    Direct and wavelength modulation technology combined with folded optical path design, measurement error ≤±6% true value @25℃
  • Good environmental adaptability
    Wide temperature compensation correction algorithm, can meet -40~+70℃ application
  • Strong anti-interference
    Methane "fingerprint spectrum" laser absorption detection technology, anti-poisoning, anti-water vapor and other gas interference;
  • Strong structural protection
    Stainless steel material design, meets the explosion-proof level Exia IIC T6 Ga
  • Low cost
    Long service life, low power consumption, modular design, easy to integrate
Dimensions

Technical Parameters:
Parameters Technical Indicators
Measuring gas Methane
Measuring principle TD-LAS
Detection mode Dispersive
Measuring range 0-20% VOL (customizable)
Measurement error @25℃ <+0.06%VOL,0-1%VOL
<+6%True value,1-20% VOL
Lower detection limit 0.2% VOL
Minimum resolution 0.01% VOL
Response time T90<15s
Operating voltage 3.0VDC ~3.6VDC
Average operating current <30mA
Peak current <210mA
Output mode Standard TTL serial port
Operating temperature -40℃~ +70℃
Operating humidity 0 ~ 99% RH (condensation)
Explosion proof sign Ex ia IICT6 Ga
Intrinsic safety parameter Ui:3.3V Ii:50mA
Pi:0.250W Ci:20uF
Li:3.14uH
Protection degree IP66
Product weight 255g
Products dimensions φ41.7mmx63.6mm
Applications:

a) The sensor continuously outputs the measured methane concentration, measured temperature, measured pressure, laser signal strength, laser operating temperature and fault code through the standard TTL serial port

b) It has a self-test function, which can detect whether the laser, photoelectric detector and voltage stabilization sensor are normal, which helps to eliminate the fault point.

Communication Interface and Definition

Interface form: SH1.0mm/4P

Cable length: 200mm

Number Color Interface definition
1 Red VCC
2 Black GND
3 Blue RX
4 Green TX
Communication Protocol

(1) Communication interface configuration

UART serial port: Baud rate: 115200, data bits: 8 bits,

Stop bit: 1 bit, parity bit: no check

(2) Description of communication protocol

Byte sequence number Function code Byte number Unit Example
0 Head of frame 1 - A
1-7 Concentration 7 %VOL +000.00
8 Blank space 1 - <SP>
9-13 Ambient temperature 5 +23.7
14 Blank space 1 - <SP>
15-21 Ambient air pressure 7 hPa 1006.22
22 Blank space 1 - <SP>
23-27 Intensity of light 5 - +16.1
28 Blank space 1 - <SP>
29-35 Gain coefficient 7 - B+6.0
36 Blank space 1 - <SP>
37-38 Fault code 2 - 00
39 Blank space 1 - <SP>
40-41 Xor check code 2 - 3D
42 Carriage return character 1 <CR>: <CR>:
43 Line break character 1 <LF> <LF>

After the sensor is powered on, it goes through a period of preprocessing (6-10s) and then begins to periodically (1Hz) output a fixed-length string. The string format is shown in the figure above.

Output string parsing (sample):

A 000.00 + 24.0 + 1006.22 + 16.1 + 006.0 B 00 13

A: the frame head;

+000.00: methane concentration value, two decimal places reserved, unit %vol;

+ 24.0: the environment temperature, the unit ℃;

1006.22: the environment pressure, the unit hPa;

16.1: the laser light intensity and effective range 3.6 21.6;

006.0: magnification factor, normal range 1.0-126.0;

00: fault codes

01: abnormal optical signal; 02; Ambient temperature or abnormal pressure; Optical signal is too strong; 04 laser temperature anomaly;

05: light signal is too weak;

13: xor check code

Fault Code
Fault code Meaning Fault code Meaning
0 Sensor working properly 3 The laser signal is strong
1 The photodetector signal is abnormal 4 Laser temperature anomaly
2 Temperature and pressure sensor abnormal 5 The laser signal is too weak
Precautions

a) The working voltage of the sensor is 3.3V, and the serial interface level is 3.3V;

b) sensor contains precision optical components, please avoid violent collision;

c) Working environment conditions: -40℃ ~ +70℃

d) Relative humidity 0-99% RH (non-condensation).

Note: The working voltage of the sensor is 3.3V. It is forbidden to connect the power supply voltage exceeding 3.6VDC to the sensor to avoid damage to the sensor.

Support and Services

We offer technical support for Gas Detector Sensors, including expert trouble, repair, and maintenance. Our services also cover calibration and testing to maintain accurate readings, and we provide product documentation and manuals. We assist with product selection and customization, ensuring the highest level of service for the optimal operation of your gas detectors.

Packing and Shipping:

Product Packaging:
Gas Detector Sensor unit
User manual
Mounting hardware
Calibration certificate
Shipping Information:
Expected delivery time: 5-8 business days

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement