China factories

Chat Now Send Email
China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Compact Low Power Methane Gas Detector Sensor with 0.2% VOL Detection Limit and
China Compact Low Power Methane Gas Detector Sensor with 0.2% VOL Detection Limit and

  1. China Compact Low Power Methane Gas Detector Sensor with 0.2% VOL Detection Limit and
  2. China Compact Low Power Methane Gas Detector Sensor with 0.2% VOL Detection Limit and

Compact Low Power Methane Gas Detector Sensor with 0.2% VOL Detection Limit and

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T,Western Union,MoneyGram
Supply Ability 1000 Pieces per Week
Delivery Time 5-8 working days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Operating temperature -40℃~ +70℃
Output mode Standard TTL Serial Port
Operating voltage 3.0VDC ~3.6VDC
Explosion proof sign Ex Ia IICT6 Ga
Product weight 255g
Protection degree IP66
Response time T90<15s
Measurement error @25℃ <+0.06%VOL,0-1%VOL <+6%True Value,1-20% VOL
Brand Name Kacise
Model Number TDLAS103
Place of Origin China (Mainland)
Certification certificate of explosion-proof, CE

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,Western Union,MoneyGram Supply Ability 1000 Pieces per Week
Delivery Time 5-8 working days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Operating temperature -40℃~ +70℃ Output mode Standard TTL Serial Port
Operating voltage 3.0VDC ~3.6VDC Explosion proof sign Ex Ia IICT6 Ga
Product weight 255g Protection degree IP66
Response time T90<15s Measurement error @25℃ <+0.06%VOL,0-1%VOL <+6%True Value,1-20% VOL
Brand Name Kacise Model Number TDLAS103
Place of Origin China (Mainland) Certification certificate of explosion-proof, CE
High Light 0.2% VOL Methane Gas Detector SensorCompact Methane Gas Detector SensorLow Power Methane Gas Detector Sensor
Introduction

The 3.3V methane laser sensor is designed using tunable diode laser absorption spectroscopy (TD-LAS), utilizing a 1653.7nm laser to detect methane via its distinct "fingerprint spectrum" absorption. It's resistant to interference from water vapor or other gases. By combining direct absorption and wavelength modulation technology, and employing an "N" type optical path structure, it achieves a long absorption path, ensuring high sensitivity and precision. The sensor also features a low-temperature laser, a photodetector, and a temperature compensation algorithm, making it adaptable to various environments. Its standardized interface and communication protocol enhance compatibility. This core component of methane detectors is ideal for applications in underground spaces, catering, industrial chemical sectors, and coal mines for gas leak detection and alarms.

Feature
  • High detection accuracy
    Direct and wavelength modulation technology combined with folded optical path design, measurement error ≤±6% true value @25℃
  • Good environmental adaptability
    Wide temperature compensation correction algorithm, can meet -40~+70℃ application
  • Strong anti-interference
    Methane "fingerprint spectrum" laser absorption detection technology, anti-poisoning, anti-water vapor and other gas interference;
  • Strong structural protection
    Stainless steel material design, meets the explosion-proof level Exia IIC T6 Ga
  • Low cost
    Long service life, low power consumption, modular design, easy to integrate
Dimensions

Technical Parameters:

ParametersTechnical Indicators
Measuring gasMethane
Measuring principleTD-LAS
Detection modeDispersive
Measuring range0-20% VOL (customizable)
Measurement error @25℃<+0.06%VOL,0-1%VOL
<+6%True value,1-20% VOL
Lower detection limit0.2% VOL
Minimum resolution0.01% VOL
Response timeT90<15s
Operating voltage3.0VDC ~3.6VDC
Average operating current<30mA
Peak current<210mA
Output modeStandard TTL serial port
Operating temperature-40℃~ +70℃
Operating humidity0 ~ 99% RH (condensation)
Explosion proof signEx ia IICT6 Ga
Intrinsic safety parameterUi:3.3V Ii:50mA
Pi:0.250W Ci:20uF
Li:3.14uH
Protection degreeIP66
Product weight255g
Products dimensionsφ41.7mmx63.6mm

Communication Interface and Definition

Interface form: SH1.0mm/4P
Cable length: 200mm

NumberColorInterface definition
1RedVCC
2BlackGND
3BlueRX
4GreenTX

Communication Protocol

(1) Communication interface configuration
UART serial port: Baud rate: 115200, data bits: 8 bits,
Stop bit: 1 bit, parity bit: no check
(2) Description of communication protocol

Byte sequence numberFunction codeByte numberUnitExample
0Head of frame1-A
1-7Concentration7%VOL+000.00
8Blank space1-<SP>
9-13Ambient temperature5+23.7
14Blank space1-<SP>
15-21Ambient air pressure7hPa1006.22
22Blank space1-<SP>
23-27Intensity of light5-+16.1
28Blank space1-<SP>
29-35Gain coefficient7-B+6.0
36Blank space1-<SP>
37-38Fault code2-00
39Blank space1-<SP>
40-41Xor check code2-3D
42Carriage return character1<CR>:<CR>:
43Line break character1<LF><LF>

After the sensor is powered on, it goes through a period of preprocessing (6-10s) and then begins to periodically (1Hz) output a fixed-length string. The string format is shown in the figure above.
Output string parsing (sample):
A 000.00 + 24.0 + 1006.22 + 16.1 + 006.0 B 00 13
A: the frame head;
+000.00: methane concentration value, two decimal places reserved, unit %vol;
+ 24.0: the environment temperature, the unit ℃;
1006.22: the environment pressure, the unit hPa;
16.1: the laser light intensity and effective range 3.6 21.6;
006.0: magnification factor, normal range 1.0-126.0;
00: fault codes
01: abnormal optical signal; 02; Ambient temperature or abnormal pressure; Optical signal is too strong; 04 laser temperature anomaly;
05: light signal is too weak;
13: xor check code

Fault Code
Fault codeMeaningFault codeMeaning
0Sensor working properly3The laser signal is strong
1The photodetector signal is abnormal4Laser temperature anomaly
2Temperature and pressure sensor abnormal5The laser signal is too weak
Support and Services

Our Gas Detector Sensor services include expert assistance with trouble and repairs, as well as maintenance, calibration, and testing to ensure precise operation. We provide product manuals and documentation, and offer guidance on selecting and customizing products. We aim to provide top-notch service to ensure your gas detectors operate effectively and reliably.

Packing and Shipping:

Product Packaging:
Gas Detector Sensor unit
User manual
Mounting hardware
Calibration certificate
Shipping Information:
Expected delivery time: 5-8 business days

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement