Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"TDLAS200 High-Sensitivity Laser Methane Sensor with 0.5ppm Detection Limit and 0","imgUrl":"https:\/\/img.chinax.com\/nimg\/38\/49\/21802eb8031e7d359ff8eea4d1e4-200x200-1\/tdlas200_high_sensitivity_laser_methane_sensor_with_0_5ppm_detection_limit_and_0.jpg","attrs":{"Detection object":"Methane (CH4)","Measurement range":"0~5000ppm","Measurement principle":"Laser absorption spectrum (TDLAS)","Product model":"TDLAS200"}}
{"title":"Highly T90\u226430s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus","imgUrl":"https:\/\/img.chinax.com\/nimg\/f2\/77\/db306f031c842b4c97432fc80d38-200x200-1\/highly_t90_e2_89_a430s_response_time_refrigerant_gas_sensor_kgd_am_204_with_rs485_modbus_output.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KGD-AM-204","Certification":"CE","Place of Origin":"CHINA"}}
{"title":"KFK-G60 Flammable Gas Sentinel with Explosion Proof Grade Ex db lIC T6 Gb\/Ex tb","imgUrl":"https:\/\/img.chinax.com\/nimg\/d7\/16\/fd40034c31f4742bc404da4fef45-200x200-1\/kfk_g60_flammable_gas_sentinel_with_explosion_proof_grade_ex_db_lic_t6_gb_2fex_tb_iiic_t80c_db_2c_4_20ma_output_current_2c_and_ip_.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KFK - G60","Certification":"CE","Place of Origin":"CHINA"}}
{"title":"Wide - Range Oxygen Sensor KGD - 324","imgUrl":"https:\/\/img.chinax.com\/nimg\/0e\/e1\/e2ec05135e972df4820cae8e04ca-200x200-1\/wide_range_oxygen_sensor_kgd_324.jpg","attrs":{"System Voltage":"10.8V - 16.5V","Measurable Air - Fuel Ratio Range":"0.65 - \u221e","Heater Resistance":"3.2\u03a9 \u00b1 0.8\u03a9","IP Rating":"IP67"}}
The KACISE TDLAS200 High-Sensitivity Laser Methane Sensor is designed for precise methane detection with unparalleled accuracy. Utilizing Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology, it offers a detection range of 0~5000ppm and a static detection limit of 0.5ppm. Its high sensitivity ensures reliable performance in various environments, with an operating temperature range of -20~50℃. The sensor features a built-in reference cell for automatic calibration and a compact design for easy integration. KACISE combines advanced technology and durability, making this sensor ideal for industrial safety and environmental monitoring.
Key Features
High sensitivity, only responds to the target gas
Built-in reference cell, can be automatically calibrated
Easy to integrate, digital interface directly outputs status and concentration
Measuring Principle
"Methane molecules absorb light of a specific wavelength" --Molecular absorption spectrum
"The amount of light absorbed by a transparent medium (methane gas mass) is proportional to the thickness and concentration of the gas mass" --Beer-Lambert's law
According to the above physical principles, a beam of light of a specific wavelength can be used to penetrate the leaking methane gas mass. According to the degree of weakening of the beam, the concentration of methane in the gas mass can be measured, and it only responds to methane (unique selectivity).
Using a detection cell with multiple reflections and allowing the laser to repeatedly pass through the gas being measured can multiply the detection sensitivity.
Technical Parameters
Product model
TDLAS200A(Pump)
TDLAS200B(Diffusion)
Detection object
Methane (CH4)
Measurement principle
Laser absorption spectrum (TDLAS)
Static detection limit
0.5ppm@25℃ 5SPS (typical value, please contact us for details)
Volume
53ml
Fastest response time
0.2s
90s
Measurement range
0~5000ppm, 0-10000ppm
Measurement deviation
0-200 ppm: ±2 ppm of the true value
200-1000 ppm: ±1% of the true value
1000-5000 ppm: ±2% of the true value
5000-10000 ppm: ±3% of the true value
*1 Please ensure that the power input voltage of the module is not less than 5V
*2 Pump selection recommendation <500ml/min
Dimensions of the detection module
(1) TDLAS200A (Pump) detection module host size 115*59*38mm (excluding cables and gas connectors).
It is recommended to add a 0.45 μm PTFE hydrophobic filter at the gas inlet; connect a pump and a muffler filter at the gas outlet.
(2) TDLAS200B (Diffusion) detection module main unit size 115*59*40mm (excluding cables and gas connectors)
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .
We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .
We have been specializing...