Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 1000 Piece/Pieces per Week negotiable |
Delivery Time | 5-8 work days |
Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Measurement Principle | NDIR dual-channel + MOX + light scattering |
Measurement Components | PM2.5 + CO₂ + CO + P |
Communication Method | CAN |
Communication Parameters | 500k |
Measurement Range | CO₂: 0~10000ppm; CO: 0~1000ppm (can display up to 10000ppm); PM: 0~5mg/m³; Air pressure P: 80kPa~120kPa |
Response Time | T90 ≤ 15s |
Model Number | KGD-ATRS-208 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
KFK - G60 - TSP Factory Dust Surveillance Pro
R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
KFK - G60 Flammable Gas Sentinel
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Measurement Principle | NDIR dual-channel + MOX + light scattering | Measurement Components | PM2.5 + CO₂ + CO + P |
Communication Method | CAN | Communication Parameters | 500k |
Measurement Range | CO₂: 0~10000ppm; CO: 0~1000ppm (can display up to 10000ppm); PM: 0~5mg/m³; Air pressure P: 80kPa~120kPa | Response Time | T90 ≤ 15s |
Model Number | KGD-ATRS-208 | Certification | CE |
Place of Origin | CHINA | ||
High Light | NDIR Battery Thermal Runaway Monitoring Sensor ,MOX Battery Thermal Runaway Monitoring Sensor |
Battery Thermal Runaway Monitoring Sensor KGD-ATRS-208
Product Introduction
The KGD-ATRS-208 battery thermal runaway monitoring sensor can effectively monitor the indicators of the concentrations of CO₂, CO, particulate matter and pressure released before the triggering of battery thermal runaway, and transmit the measurement signals to the BMS through CAN or LIN communication (customizable). It has remarkable features such as accurate measurement, fast response time, low cross-interference, low power consumption, long service life, and high reliability.
Product Features
Technical Parameters
Measurement Principle | NDIR dual-channel + MOX + light scattering |
Measurement Components | PM2.5 + CO₂ + CO + P |
Communication Method | CAN |
Communication Parameters | 500k |
Measurement Range | CO₂: 0~10000ppm; CO: 0~1000ppm (can display up to 10000ppm); PM: 0~5mg/m³; Air pressure P: 80kPa~120kPa |
Response Time | T90 ≤ 15s |
Measurement Precision | CO₂: ±200ppm or ±20% of the reading @0~5000ppm & -20°C~60°C; CO: take the larger value between ±40ppm or ±30% of the reading; PM: ≤100ug/m³: ±15ug/m³; >100ug/m³: ±15% of the reading @-40℃~70℃; Pressure P: ±1kPa |
Resolution | CO₂/CO: 1ppm; PM: 1μg/m³; Air pressure P: 0.1kPa |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!