China Continuous Ammonia Emissions Monitoring System with TDLAS Technology, 0.01ppm
China Continuous Ammonia Emissions Monitoring System with TDLAS Technology, 0.01ppm

  1. China Continuous Ammonia Emissions Monitoring System with TDLAS Technology, 0.01ppm

Continuous Ammonia Emissions Monitoring System with TDLAS Technology, 0.01ppm

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measurement Principle TDLAS
Range 0 - 10 - 100ppm adjustable
Accuracy ± 1%F.S.
Repeatability ± 1%
Resolution 0.01ppm
Minimum Detection Limit ≤ 1ppm
Brand Name KACISE
Model Number KGD-YQ-523
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measurement Principle TDLAS Range 0 - 10 - 100ppm adjustable
Accuracy ± 1%F.S. Repeatability ± 1%
Resolution 0.01ppm Minimum Detection Limit ≤ 1ppm
Brand Name KACISE Model Number KGD-YQ-523
Certification CE Place of Origin CHINA
High Light Stationary Pollution Sources Continuous Monitoring SystemExhaust Gases Continuous Monitoring System

Continuous Monitoring System for Ammonia Emissions from Exhaust Gases of Stationary Pollution Sources (NH₃ - CEMS) KGD - YQ - 523

Product Introduction

The Continuous Monitoring System for Ammonia Emissions from Exhaust Gases of Stationary Pollution Sources (NH₃ - CEMS) KGD - YQ - 523 adopts Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology and is suitable for online monitoring of ammonia concentration at the outlet of the denitrification process. The system uses a near - extraction method, with the measurement unit installed outside the flue wall. The gas - path channel in contact with the sample gas is heated throughout the process to avoid ammonia adsorption and loss, ensuring the authenticity of the sample gas. It can accurately reflect the changes in ammonia slip in real - time, providing reliable data support for environmental protection monitoring.

Product Features

  • Adopting TDLAS technology, the measured gas is not affected by cross - interference from background gases.
  • Ultra - low range measurement. Using a multi - reflection gas cell, it has a low detection limit.
  • The system uses a full - process calibration method to improve the accuracy of measurement results.
  • The gas flow path is heated throughout the process, and low - adsorption materials and processing techniques are used to effectively avoid NH₃ condensation loss.
  • Extraction - type measurement, not affected by fluctuations in dust, temperature, and pressure inside the flue.
  • Equipped with a full - process calibration function.

Technical Parameters

Measurement Component NH₃
Measurement Principle TDLAS
Range 0 - 10 - 100ppm adjustable
Accuracy ± 1%F.S.
Repeatability ± 1%
Resolution 0.01ppm
Minimum Detection Limit ≤ 1ppm
Protection Level IP65 or above
Response Time T90 ≤ 30s
Working Conditions Working conditions
Ambient Temperature -30 - 60°C
Ambient Humidity 5 - 85%RH
Working Power Supply 220VAC, 50Hz, 800W
Purge Gas Source 0.4 - 0.8MPa compressed air
Communication 1 - way RS - 232, 1 - way RS - 485
Output Mode 4 - way 4 - 20mA output, 8 - way relay output

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.