| Measuring Range | NO2: 0 - 1000 ppm |
| Indicated Value Error | Relative error < ±4%; Absolute error < ±25 ppm (satisfy either one of the two) |
| Resolution | 1 ppm |
| Response Time | T90 ≤ 4.5 s |
| Communication | RS - 232, can connect to Gasboard series exhaust gas |
| Power Supply | 12V ± 0.2V, 2A |
| Brand Name | KACISE |
| Model Number | KGD-WQ-533 |
| Certification | CE |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
KFK - G60 - TSP Factory Dust Surveillance Pro
M20*1.5 Mounting Thread Nitrogen Oxide Sensor KGD 325 For Diesel Vehicle
R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
Product Specification
| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measuring Range | NO2: 0 - 1000 ppm | Indicated Value Error | Relative error < ±4%; Absolute error < ±25 ppm (satisfy either one of the two) |
| Resolution | 1 ppm | Response Time | T90 ≤ 4.5 s |
| Communication | RS - 232, can connect to Gasboard series exhaust gas | Power Supply | 12V ± 0.2V, 2A |
| Brand Name | KACISE | Model Number | KGD-WQ-533 |
| Certification | CE | Place of Origin | CHINA |
| High Light | NDUV Ultraviolet Gas Sensor Module ,Ultra - Low Range Gas Sensor Module | ||
KGD - WQ - 533 Series NDUV Ultraviolet Ultra - low Range Gas Sensor Module
Product Introduction
The KGD - WQ - 533 series NDUV ultraviolet ultra - low range gas sensor module adopts the Non - Dispersive Ultraviolet Absorption (NDUV) technology. The ultraviolet light beam passes through the measuring gas chamber and is absorbed and attenuated. Then, the concentration of the measured gas is calculated based on the absorption relationship of the Lambert - Beer law. This product uses a highly stable ultraviolet light source and, through a unique optical path design, can directly measure NO₂ gas without a converter furnace, featuring high measurement accuracy, strong stability, and being unaffected by the conversion efficiency of the converter furnace.
![]()
Product Features
Technical Parameters
| Parameter | Value |
| Measuring Range | NO2: 0 - 1000 ppm |
| Indicated Value Error | Relative error < ±4%; Absolute error < ±25 ppm (satisfy either one of the two) |
| Resolution | 1 ppm |
| Response Time | T90 ≤ 4.5 s |
| Communication | RS - 232, can connect to Gasboard series exhaust gas |
| Power Supply | 12V ± 0.2V, 2A |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!