China KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer
China KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer

  1. China KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer

KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO₂, CH₄, N₂O, CO, O₂
Measurement Range - Methane (CH₄) Range 0 - 1000 ppm, Resolution 1 ppm
Measurement Range - Nitrous Oxide (N₂O) Range 0 - 1000 ppm, Resolution 1 ppm
Measurement Range - Oxygen (O₂) Range 0 - 25%, Resolution 0.01%
Repeatability ≤±1%
Response Time T90 < 25s
Brand Name KACISE
Model Number KGD-YQ-501
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO₂, CH₄, N₂O, CO, O₂ Measurement Range - Methane (CH₄) Range 0 - 1000 ppm, Resolution 1 ppm
Measurement Range - Nitrous Oxide (N₂O) Range 0 - 1000 ppm, Resolution 1 ppm Measurement Range - Oxygen (O₂) Range 0 - 25%, Resolution 0.01%
Repeatability ≤±1% Response Time T90 < 25s
Brand Name KACISE Model Number KGD-YQ-501
Certification CE Place of Origin CHINA
High Light N₂O Greenhouse Gas Emission AnalyzerCH₄ Greenhouse Gas Emission AnalyzerCO₂ Greenhouse Gas Emission Analyzer

KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer

Product Introduction

The KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer employs micro - flow infrared half - cell gas sensing technology. It enables simultaneous and accurate measurement of concentration changes of greenhouse gases such as CO₂, CH₄, N₂O, as well as CO gas in flue gas. The measuring range can reach as low as 200 ppm, with an accuracy of up to 1% F.S. It features strong resistance to gas cross - interference and lower drift.

 

Moreover, to meet the measurement requirements for high - concentration CO₂ and medium - to - high - range CO, sensor modules with Non - Dispersive Infrared (NDIR) gas sensor technology can be optionally configured for flexibility. These modules are characterized by good stability, small size, and low cost.

Product Features

One analyzer can simultaneously and continuously measure up to five gases, including CO₂, CH₄, N₂O, CO, and O₂.

For CO₂, CH₄, N₂O, and CO, the patented micro - flow infrared technology can be selected, with a measuring range as low as 200 ppm and an accuracy of up to 1% F.S.

Small drift, resistant to moisture interference, and stable for long - term use.

For medium - to - high - concentration measurement needs, dual - beam infrared sensing technology can be used to measure CO₂ and CO, allowing for flexible combinations.

It has both digital and analog signal output functions, enabling simple and convenient data management.

Technical Parameters

Parameter Details
Measured Components CO₂, CH₄, N₂O, CO, O₂
Measurement Principle Micro - flow NDIR: CO₂/CH₄/N₂O/CO
Dual - beam NDIR: CO₂ (high range) and CO (medium - high range)
Electrochemical (ECD): O₂
Measurement Range - Carbon Dioxide (CO₂) Micro - flow: Range 0 - 500 ppm, Resolution 1 ppm
Micro - flow: Range 0 - 20%, Resolution 0.01%
Dual - beam: Range 0 - 25/100%, Resolution 0.01%
Measurement Range - Methane (CH₄) Range 0 - 1000 ppm, Resolution 1 ppm
Measurement Range - Nitrous Oxide (N₂O) Range 0 - 1000 ppm, Resolution 1 ppm
Measurement Range - Carbon Monoxide (CO) Micro - flow: Range 0 - 200/5000 ppm, Resolution 1 ppm
Dual - beam: Range 0 - 1/5%, Resolution 0.001%
Measurement Range - Oxygen (O₂) Range 0 - 25%, Resolution 0.01%
Measurement Accuracy Micro - flow NDIR for CO₂/CH₄/N₂O/CO: ±1% F.S.
Dual - beam NDIR for CO₂/CO: ±2% F.S.
ECD for O₂: ±2% F.S.
Repeatability ≤±1%
Response Time T90 < 25s
Optimal Flow Rate (0.7 - 1.2) L/min
Inlet Gas Pressure (2 - 50) Kpa
Sample Gas Requirements Dewatered (no condensation); Dust - filtered (filtration accuracy < 1μm)
Signal Output RS - 485/RS - 232, (4 - 20)mA
Power Supply 100 - 240VAC, 3000W (maximum heating power)/100W (stable power)
Diagnostic Function Has a self - diagnostic function to check the sensor status

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement