| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days |
| Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Maximum measuring distance | 22m |
| Multi-target detection | Double peak |
| Enclosure protection level | IP65 |
| Blind area | 0.03m |
| Working voltage | DC+9~35V |
| Working laser | 905nm,Class 1 |
| Brand Name | KACISE |
| Model Number | KLSA series |
| Certification | CE |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
LSDM Security Surveillance Long-Range DtoF Laser Ranging Module with 1500m Range
Outdoor High - Performance KLSA Laser Distance Sensor
High-Precision Laser Ranging Module with ±3mm Accuracy, 100m Range, and 20Hz
Outdoor Long Distance Laser Radar Ranging Module with Absolute Accuracy ±1m and
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Maximum measuring distance | 22m | Multi-target detection | Double peak |
| Enclosure protection level | IP65 | Blind area | 0.03m |
| Working voltage | DC+9~35V | Working laser | 905nm,Class 1 |
| Brand Name | KACISE | Model Number | KLSA series |
| Certification | CE | Place of Origin | CHINA |
| High Light | Surveying Laser Ranging Sensors ,Engineering Construction Laser Ranging Sensors ,KLSA series Laser Ranging Sensors | ||
The KLSA series laser ranging sensors for surveying and engineering construction.
Introduction
The KLSA series laser ranging sensors are specialized tools designed to meet the rigorous demands of surveying and engineering construction. Built with advanced laser technology, these sensors deliver high-precision, non-contact distance measurements to support tasks such as site planning, structural alignment, and progress monitoring in construction environments.
Key Features
Applications
Technical Specifications
Communication: Isolated RS485 with adjustable baud rates (9600–115200 bps) and CRC16 check for reliable data transmission.
Safety: Laser on/off control reduces visual interference during surveys, while fault status registers (e.g., 0000H for over-range alerts) enhance diagnostic capabilities.
The KLSA series combines precision, durability, and adaptability, making it an indispensable tool for professionals in surveying and engineering construction who require reliable, real-time distance measurement solutions.
| Performance parameters | |||||
| Measurement range | Maximum measuring distance: 22m | ||||
| Under strong light @100KLux environment: 12m | |||||
| Under black target with 10% reflectivity: 20m | |||||
| Measurement frequency | 100HZ (frequency adjustable) | ||||
| Repeat accuracy | ±8.0mm @50~2000mm | ||||
| ±20.0mm @2000~6000mm | |||||
| ±30.0mm @6000~20000mm | |||||
| Absolute accuracy | ±20.0mm@200~2000mm; 20~200mm near blind area, large error | ||||
| ±30.0mm @2000~6000mm | |||||
| <1% @6000~20000mm | |||||
| Multi-target detection | Double peak | ||||
| Temperature compensation | Yes | ||||
| Reflectivity correction | Yes, the deviation of different color targets is less than 5mm | ||||
| Blind area | 0.03m | ||||
| Light source | |||||
| Working laser | 905nm,Class 1 | ||||
| Field of view FOV | <2° | ||||
| Spot size |
Φ3.5cm@1m: Φ11.5cm@5m Φ23cm@10m; Φ50cm@20m |
||||
| Indicator laser | 650-660nm,Class 2, (IEC 60825-1:2014, EN 60825-1:2014) | ||||
| Working environment | |||||
| Working temperature | -20~50℃ | ||||
| Storage temperature | -40~85℃ | ||||
| Enclosure protection level | IP65 | ||||
| Electrical Parameters | |||||
| Working voltage | DC+9~35V | ||||
| Working current | 107mA@12V indicates laser working | ||||
| 103mA@12V indicates laser off | |||||
| Reverse protection | Yes | ||||
| Isolation | Yes | ||||
| Laser life | More than 50000h | ||||
| Output interface | |||||
| Output interface | Two-way PNP | Two-way NPN | RS485-Modbus |
UART |
Relay |
| Normally open/closed | Normally open/closed | 4~20mA | |||
| Switch output maximum current load | 100mA | ||||
| Analog output maximum load | 250Ω | ||||
| Display button | |||||
| Nixie tube digits | 4-bit | ||||
| Button function | Switch value adjustment; laser switch indication; analog range adjustment | ||||
| Mechanical parameters | |||||
| Weight | 73g+3g (glue filling error) | ||||
| Casing | ABS | ||||
| Dimensions | 45*45*49.5mm | ||||
| Accessories | |||||
| Bolts | M4*55mm 2 | ||||
| Bracket | Optional | ||||
| Electrical connection | 1*M8, 1 meter long cable | ||||
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!