| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days |
| Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measurement Components | NO, O₂, CO, CO₂ |
| Measurement Principle | NO, CO, O₂: ECD; CO₂: NDIR |
| Measurement Range | NO: 0 - 100mg/m²; CO₂, O₂: 0 - 25%; CO: 0 - 5% |
| Accuracy | ≤ 3%F.S. |
| Response Time | ≤ 30s |
| Brand Name | KACISE |
| Model Number | KGD-YQ-528 |
| Place of Origin | CHINA |
| Certification | CE |
View Detail Information
Explore similar products
Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
KFK - G60 - TSP Factory Dust Surveillance Pro
M20*1.5 Mounting Thread Nitrogen Oxide Sensor KGD 325 For Diesel Vehicle
R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
Product Specification
| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measurement Components | NO, O₂, CO, CO₂ | Measurement Principle | NO, CO, O₂: ECD; CO₂: NDIR |
| Measurement Range | NO: 0 - 100mg/m²; CO₂, O₂: 0 - 25%; CO: 0 - 5% | Accuracy | ≤ 3%F.S. |
| Response Time | ≤ 30s | Brand Name | KACISE |
| Model Number | KGD-YQ-528 | Place of Origin | CHINA |
| Certification | CE | ||
| High Light | Standard Version Gas Emission Monitoring System ,Boiler Gas Emission Monitoring System | ||
Boiler Flue Gas Emission Monitoring System (Standard Version) KGD - YQ - 528
Product Introduction
The KGD - YQ - 528 Boiler Flue Gas Emission Monitoring System (Standard Version) is based on non - dispersive infrared gas analysis technology and long - life electrochemical sensing technology. It is equipped with an integrated and automated sampling pretreatment unit and control unit. It can simultaneously measure the gas concentrations of NO, O₂, CO, and CO₂ in flue gas online. It is an online monitoring device specifically designed for boiler air pollutant emission and energy - efficiency control, meeting the regulatory requirements of national and local environmental protection departments.
![]()
Product Features
Technical Parameters
| Measurement Components | NO, O₂, CO, CO₂ |
| Measurement Principle | NO, CO, O₂: ECD; CO₂: NDIR |
| Measurement Range | NO: 0 - 100mg/m²; CO₂, O₂: 0 - 25%; CO: 0 - 5% |
| Accuracy | ≤ 3%F.S. |
| Response Time | ≤ 30s |
| Working Parameters | |
| Working Power Supply | 220V AC ± 20%, 50Hz ± 1Hz |
| Display | Liquid crystal display |
| Interface Signal | Interface signal |
| Communication | Standard RS232, RS485, DC(4 - 20)mA current output, one - way audible and visual alarm output |
| Functional Configuration | With data storage function (can store three - year historical data) |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!