| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days |
| Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measurement Principle | Optical Scattering Principle |
| Measurement Range | 0 - 20mg/m³ |
| Indication Error | ≤ ± 10%F.S. |
| Minimum Detection Limit | 0.01mg/m³ |
| Zero - point Drift | ± 2%F.S./168h |
| Span Point Drift | ± 2%F.S./168h |
| Brand Name | KACISE |
| Model Number | KGD-YQ-540 |
| Certification | CE |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
KFK - G60 - TSP Factory Dust Surveillance Pro
M20*1.5 Mounting Thread Nitrogen Oxide Sensor KGD 325 For Diesel Vehicle
R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
| Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Measurement Principle | Optical Scattering Principle | Measurement Range | 0 - 20mg/m³ |
| Indication Error | ≤ ± 10%F.S. | Minimum Detection Limit | 0.01mg/m³ |
| Zero - point Drift | ± 2%F.S./168h | Span Point Drift | ± 2%F.S./168h |
| Brand Name | KACISE | Model Number | KGD-YQ-540 |
| Certification | CE | Place of Origin | CHINA |
| High Light | Flue Gas Dust Sensor Module ,KGD YQ 540 Dust Sensor Module ,Flue Gas Dust Sensor | ||
The KGD - YQ - 540 Flue Gas Dust Sensor Module adopts the optical scattering principle and can accurately detect the mass concentration of suspended particulate matter in the flue gas per unit volume. When the dust particles in the sample gas pass through the laser beam in the constant - temperature measuring gas cell, a light scattering signal is generated. Then, the photoelectric converter converts the scattered light signal into an electrical signal, and the real - time particulate matter mass concentration data is obtained by calculating the relationship between the signal intensity and the concentration. The product complies with the detection requirements of the national standard HJ 76 - 2017 "Technical Requirements and Detection Methods for Continuous Emission Monitoring Systems of Flue Gas (SO₂, NOₓ, Particulate Matter) from Stationary Pollution Sources.
![]()
| Measurement Principle | Optical Scattering Principle |
| Measurement Range | 0 - 20mg/m³ |
| Indication Error | ≤ ± 10%F.S. |
| Minimum Detection Limit | 0.01mg/m³ |
| Zero - point Drift | ± 2%F.S./168h |
| Span Point Drift | ± 2%F.S./168h |
| Gas Temperature | ≤ 300 °C |
| Data Update Frequency | 1s /per time |
| Working Conditions | -20 - 50 °C; 5 - 95%RH (Non - condensing) |
| Storage Conditions | -40 - 85 °C; 5 - 95%RH (Non - condensing) |
| Anti - clogging Measure | Gas - curtain Protection |
| Working Voltage | DC 12V + 0.5V, Ripple < 100mV |
| Average Working Current | < 500mA |
| Communication Interface | UART_TTL (3.3V) |
| Product Dimensions (WHD) | 272mm * 111mm * 193mm |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us