China factories

Chat Now Send Email
China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China KGD-MQ-526 Online Gas Analysis System with NDIR Measurement Principle, Ex d IIC
China KGD-MQ-526 Online Gas Analysis System with NDIR Measurement Principle, Ex d IIC

  1. China KGD-MQ-526 Online Gas Analysis System with NDIR Measurement Principle, Ex d IIC

KGD-MQ-526 Online Gas Analysis System with NDIR Measurement Principle, Ex d IIC

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO/CO2/CH4/H2/O2/C2H2/C2H4/CnHm*/Calorific Value
Measurement Principle CO/CO2/CH4/C2H2/C2H4/CnHm: NDIR; H2: TCD; O2: ECD
Measurement Range CO/CO2/CH4/H2: (0 - 100%)
Measurement Range (Optional) O2: (0 - 25%); C2H2/C2H4/CnHm: (0 - 10%)
Accuracy CO/CO2/CH4/C2H2/C2H4/CnHm: ±1%F.S.; H2/O2: ±2%F.S.
Explosion - proof Grade Ex d IIC T4 Gb
Brand Name KACISE
Model Number KGD-MQ-526
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO/CO2/CH4/H2/O2/C2H2/C2H4/CnHm*/Calorific Value Measurement Principle CO/CO2/CH4/C2H2/C2H4/CnHm: NDIR; H2: TCD; O2: ECD
Measurement Range CO/CO2/CH4/H2: (0 - 100%) Measurement Range (Optional) O2: (0 - 25%); C2H2/C2H4/CnHm: (0 - 10%)
Accuracy CO/CO2/CH4/C2H2/C2H4/CnHm: ±1%F.S.; H2/O2: ±2%F.S. Explosion - proof Grade Ex d IIC T4 Gb
Brand Name KACISE Model Number KGD-MQ-526
Certification CE Place of Origin CHINA
High Light KGD - MQ - 526 Gas Analysis SystemExplosion proof Online Gas Analysis System
KGD-MQ-526 Online Gas Analysis System
Product Overview

The KGD-MQ-526 Online Gas Analysis System is engineered for applications with low dust content in sample gases. This comprehensive system comprises three integrated components: pretreatment unit, control unit, and gas analysis unit. Utilizing proprietary non-dispersive infrared (NDIR) gas analysis technology, it enables continuous, simultaneous real-time measurement of gas and biogas calorific values, while calculating volume concentrations and calorific values for multi-component gases including CO, CO₂, CH₄, H₂, O₂, and CnHm.

KGD-MQ-526 Online Gas Analysis System
Key Features
  • Pretreatment Unit: Features extended service life and stable performance with stainless steel, electrically-heated temperature-controlled dry sampling probe for high precision and longevity. Advanced back-purging technology prevents probe clogging, while single-stage refrigeration and two-stage filtration ensure reliable long-term online operation.
  • Control Unit: PLC-programmed for fully automated detection with simple operation, automatically managing sampling, back-blowing, and drainage processes.
  • Gas Analysis Unit: Simultaneously measures gas volume concentration and calorific value for comprehensive analysis.
  • Low Maintenance & Operation Costs: Real-time system status monitoring eliminates need for manual attendance, significantly reducing operational expenses.
  • Intelligent Data Management: Multiple interface options for data transmission to centralized control systems, providing real-time basis for remote monitoring and process optimization.
Technical Specifications
Parameter Details
Measured Components CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CnHm*/Calorific Value
Measurement Principle CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: NDIR; H₂: TCD; O₂: ECD
Measurement Range CO/CO₂/CH₄/H₂: (0-100%)
Measurement Range (Optional) O₂: (0-25%); C₂H₂/C₂H₄/CnHm: (0-10%)
Accuracy CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1%F.S.; H₂/O₂: ±2%F.S.
Explosion-proof Grade Ex d IIC T4 Gb
Display LCD Display
Communication RS-232/RS-485, (4-20) mA, Ethernet
Functional Configuration Self-diagnosis function available, sensor status can be checked online
Functional Configuration Built-in zero-adjustment air pump for automatic air zero-adjustment

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement