China KGD-MQ-523 Laser Raman Spectroscopy Gas Analyzer for Real-time Detection and
China KGD-MQ-523 Laser Raman Spectroscopy Gas Analyzer for Real-time Detection and

  1. China KGD-MQ-523 Laser Raman Spectroscopy Gas Analyzer for Real-time Detection and

KGD-MQ-523 Laser Raman Spectroscopy Gas Analyzer for Real-time Detection and

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Iron and Steel Metallurgy Industry CO, CO2, CH4, C2H2, C2H4, C2H6, C3H8, O2, H2, N2, H2S...
Petroleum and Natural Gas Industry CH4, CO, CO2, H2S, C2H6, C2H4, C3H6, C3H8, H2...
Primary Aluminum Industry CO, CO2...
Environmental Protection Industry H2, N2, O2, CO, CO2, CH4, C2H2, C2H4, C3H6, C3H8, H2S...
Power Industry CO, CO2, H2S, CH4, H2O...
Cement Industry CO, CO2, H2O, H2S...
Brand Name KACISE
Model Number KGD-MQ-523
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Iron and Steel Metallurgy Industry CO, CO2, CH4, C2H2, C2H4, C2H6, C3H8, O2, H2, N2, H2S... Petroleum and Natural Gas Industry CH4, CO, CO2, H2S, C2H6, C2H4, C3H6, C3H8, H2...
Primary Aluminum Industry CO, CO2... Environmental Protection Industry H2, N2, O2, CO, CO2, CH4, C2H2, C2H4, C3H6, C3H8, H2S...
Power Industry CO, CO2, H2S, CH4, H2O... Cement Industry CO, CO2, H2O, H2S...
Brand Name KACISE Model Number KGD-MQ-523
Certification CE Place of Origin CHINA
High Light Primary Aluminum Industries Gas AnalyzerAccurate CO Measurement Gas AnalyzerCement Gas Analyzer
KGD-MQ-523 Laser Raman Spectroscopy Gas Analyzer
The KGD-MQ-523 Laser Raman Spectroscopy Gas Analyzer utilizes laser Raman scattering technology to enhance, collect, process, and identify characteristic Raman scattering spectra of target gases. This enables simultaneous online, real-time detection and quantitative analysis of multiple gas components.
KGD-MQ-523 Laser Raman Spectroscopy Gas Analyzer
Product Features
  • Utilizes laser Raman gas characteristic fingerprint technology with minimal interference
  • Capable of measuring most gases except inert gases, including N₂, O₂, H₂, CH₄, C₂H₆, C₃H₈, H₂S, etc.
  • Fast response speed - measurement results displayed within 30 seconds of sample gas entry
  • Wide measurement range from (0-10)% to (0-100)%
  • Gas concentration normalization algorithm with automatic air-extraction calibration to prevent long-term drift
  • Low operational and maintenance costs with no carrier gas or consumables required
  • Optional integrated system for real-time cyclic monitoring of multiple points
  • Intuitive full-touch screen interface with external PC keyboard connectivity
Product Advantages
  • Online, Real-time Full-component Analysis: Capable of replacing Gas Chromatography (GC) and Mass Spectrometry (MS)
  • vs. Infrared Analysis (NDIR): Larger range and ability to detect homonuclear diatomic molecules (N₂, O₂, H₂) with higher precision
  • vs. Gas Chromatography (GC): No carrier gas or consumables required, faster response time, easier operation, lower cost
  • vs. Mass Spectrometry (MS): More durable, easier operation, lower maintenance costs, better suited for harsh industrial environments
Technical Parameters
Industry Application Fields Gases Monitored
Coal Chemical Industry Coal Gasifier, Coal-to-Natural Gas, Synthetic Ammonia/Urea CO, CO₂, H₂, N₂, O₂, CH₄, C₂H₂, C₂H₄, C₂H₆, C₃H₈, H₂S...
Iron and Steel Metallurgy Industry Various metallurgical processes CO, CO₂, CH₄, C₂H₂, C₂H₄, C₂H₆, C₃H₈, O₂, H₂, N₂, H₂S...
Petroleum and Natural Gas Industry Oil and gas processing CH₄, CO, CO₂, H₂S, C₂H₆, C₂H₄, C₃H₆, C₃H₈, H₂...
Primary Aluminum Industry Aluminum production CO, CO₂...
Environmental Protection Industry Environmental monitoring H₂, N₂, O₂, CO, CO₂, CH₄, C₂H₂, C₂H₄, C₃H₆, C₃H₈, H₂S...
Power Industry Power generation CO, CO₂, H₂S, CH₄, H₂O...
Cement Industry Cement production CO, CO₂, H₂O, H₂S...
Basic Parameters:
Range: Minimum 0-10%, Maximum 0-100%
Linear Error: ≤ ±1% F.S.
Resolution: 0.01%
Response Time: ≤30s
Dimensions: 1000×800×1780 (mm)

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement