China KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites
China KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites

  1. China KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites

KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO, CO₂, O₂, Flue Gas Temperature; SO₂, NO, NO₂ sensors can be extended
Measurement Principle O₂: ECD; CO/CO₂: NDIR; Flue Gas Temperature: K - type thermocouple or S - type thermocouple
Measurement Range O₂: (0 - 21)%; CO: (0 - 5000) ppm; CO₂: (0 - 25)%; Flue Gas Temperature: (0 - 800)/(0 - 1200)℃
Linear Error CO/CO₂: ±1%F.S.; O₂: ±2%F.S.; Flue Gas Temperature: ±3℃; or ±1% of measured value
Resolution O₂: 0.01%; CO: 1ppm; CO₂: 0.01%; Flue Gas Temperature: 0.1℃
Repeatability ≤ 2%
Brand Name KACISE
Model Number KGD-MQ-514
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO, CO₂, O₂, Flue Gas Temperature; SO₂, NO, NO₂ sensors can be extended Measurement Principle O₂: ECD; CO/CO₂: NDIR; Flue Gas Temperature: K - type thermocouple or S - type thermocouple
Measurement Range O₂: (0 - 21)%; CO: (0 - 5000) ppm; CO₂: (0 - 25)%; Flue Gas Temperature: (0 - 800)/(0 - 1200)℃ Linear Error CO/CO₂: ±1%F.S.; O₂: ±2%F.S.; Flue Gas Temperature: ±3℃; or ±1% of measured value
Resolution O₂: 0.01%; CO: 1ppm; CO₂: 0.01%; Flue Gas Temperature: 0.1℃ Repeatability ≤ 2%
Brand Name KACISE Model Number KGD-MQ-514
Certification CE Place of Origin CHINA
High Light Industrial Sites Combustion Efficiency AnalyzerKGD Combustion Efficiency Analyzer

KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites

Product Introduction

The KGD - MQ - 514 Combustion Efficiency Analyzer adopts non - dispersive infrared (NDIR) gas analysis technology with independent intellectual property rights and long - life electrochemical sensing technology. It can simultaneously measure the volume concentrations of gases such as CO, CO₂, and O₂, as well as the flue gas temperature, and calculate the excess air coefficient, providing a basis for adjusting the combustion conditions in industrial sites.

Product Features

  • Simultaneously measures flue gas components and temperature: It can simultaneously measure the volume concentrations of gases such as CO, CO₂, and O₂ in the flue gas, and automatically calculate and display the flue gas temperature and the excess air coefficient.
  • High measurement accuracy: It has a wide measurement range. The sensor will not be damaged due to over - range, and it has a long service life and high accuracy.
  • Portable body design: Equipped with an integrated imported sampling gun, it is easy to carry and can meet the needs of both on - site industrial measurement and laboratory airbag sampling analysis.
  • Intelligent power management: It is equipped with a soft - start power switch to prevent the instrument from operating under low - power conditions.
  • Simple data management: It automatically stores measurement data, has query and deletion functions, and can transmit data to the superior centralized control system through multiple interfaces.

Technical Parameters

Measured Components CO, CO₂, O₂, Flue Gas Temperature; SO₂, NO, NO₂ sensors can be extended
Measurement Principle O₂: ECD; CO/CO₂: NDIR; Flue Gas Temperature: K - type thermocouple or S - type thermocouple
Measurement Range O₂: (0 - 21)%; CO: (0 - 5000) ppm; CO₂: (0 - 25)%; Flue Gas Temperature: (0 - 800)/(0 - 1200)℃
Linear Error CO/CO₂: ±1%F.S.; O₂: ±2%F.S.; Flue Gas Temperature: ±3℃; or ±1% of measured value
Resolution O₂: 0.01%; CO: 1ppm; CO₂: 0.01%; Flue Gas Temperature: 0.1℃
Repeatability ≤ 2%
Operating Temperature (0 - 50)℃
Relative Humidity (5 - 85)%
Response Time T90 < 15s (NDIR)
Electrical Parameters Electrical Parameters
Communication RS - 232/RS - 485
Battery Power Supply Powered by built - in rechargeable lithium - ion battery, with an external 12.6V charger, can work continuously for more than 10 hours
AC Power Supply 100 - 240VAC, 80W
Display LCD Display
Functional Configuration Built - in imported sampling air pump, anti - pressure capacity 200hPa
Self - diagnosis function available for on - line inspection of sensor status
Optional pretreatment device

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement