{"title":"Laser Raman Spectroscopy Gas Analyzer KGD - MQ - 501","imgUrl":"https:\/\/img.chinax.com\/nimg\/c6\/10\/1538c203d140c22614a72cee433f-200x200-1\/laser_raman_spectroscopy_gas_analyzer_kgd_mq_501.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KGD-MQ-501","Certification":"CE","Place of Origin":"CHINA"}}
{"title":"Highly T90\u226430s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus","imgUrl":"https:\/\/img.chinax.com\/nimg\/f2\/77\/db306f031c842b4c97432fc80d38-200x200-1\/highly_t90_e2_89_a430s_response_time_refrigerant_gas_sensor_kgd_am_204_with_rs485_modbus_output.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KGD-AM-204","Certification":"CE","Place of Origin":"CHINA"}}
{"title":"KFK-G60 Flammable Gas Sentinel with Explosion Proof Grade Ex db lIC T6 Gb\/Ex tb","imgUrl":"https:\/\/img.chinax.com\/nimg\/d7\/16\/fd40034c31f4742bc404da4fef45-200x200-1\/kfk_g60_flammable_gas_sentinel_with_explosion_proof_grade_ex_db_lic_t6_gb_2fex_tb_iiic_t80c_db_2c_4_20ma_output_current_2c_and_ip_.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KFK - G60","Certification":"CE","Place of Origin":"CHINA"}}
{"title":"Wide - Range Oxygen Sensor KGD - 324","imgUrl":"https:\/\/img.chinax.com\/nimg\/0e\/e1\/e2ec05135e972df4820cae8e04ca-200x200-1\/wide_range_oxygen_sensor_kgd_324.jpg","attrs":{"Brand Name":"KACISE","Model Number":"KGD-324","Certification":"CE","Place of Origin":"CHINA"}}
Laser Raman Spectroscopy Gas Analyzer KGD - MQ - 501
Product Introduction
The KGD - MQ - 501 Laser Raman Spectroscopy Gas Analyzer is based on the principle of laser Raman scattering. It enhances, collects, processes and identifies the characteristic Raman scattering spectra of the gases to be measured, and conducts quantitative calculations of their contents. It can simultaneously perform on - line and real - time detection of multiple gases.
Product Features
Adopts laser Raman gas characteristic fingerprint technology with less interference.
Can measure most gases except inert gases, including N₂, O₂, H₂, CH₄, C₂H₆, C₃H₈, H₂S and other gases.
Fast response speed. The measurement results are displayed 30 seconds after the sample gas enters the analyzer.
Capable of measuring gas concentrations in a wide range. The minimum range is (0 - 10)%, and the maximum range is (0 - 100)%.
Adopts gas concentration normalization algorithm and automatic air - extraction calibration to prevent long - term drift.
Low cost of use and maintenance. No carrier gas or consumables are required.
An optional integrated system is available to achieve real - time cyclic monitoring of multiple monitoring points.
Intelligent software design with a full - touch screen interface. Data is displayed intuitively, and an external PC keyboard can be connected.
Product Advantages:
On - line, real - time, and full - component analysis, which can replace Gas Chromatography (GC) and Mass Spectrometry (MS).
Compared with Non - dispersive Infrared (NDIR) analysis technology: NDIR gas analyzers have a small measurement range and cannot detect homonuclear diatomic molecules such as N₂, O₂, and H₂. The KGD - MQ - 501 has the ability to detect multi - component gas compositions, especially can accurately measure diatomic molecules in natural gas, and has a wider range and higher accuracy.
Compared with Gas Chromatography (GC) technology: Gas chromatographs require carrier gas and chromatographic columns, and the response time usually ranges from several minutes to dozens of minutes, and need to be operated by professional technicians. The KGD - MQ - 501 has an extremely short response time, requires no carrier gas or consumables, is easy to operate, and has a low cost of use.
Compared with Mass Spectrometry (MS) analysis technology: Mass spectrometers are expensive, have high maintenance costs, and are complex to operate, and are rarely used for on - line analysis in industrial fields. The KGD - MQ - 501 is robust, easy to operate, and has low maintenance costs, making it more suitable for harsh industrial sites.
Technical Parameters
Industry
Application Fields
Gases to be Monitored
Coal Chemical Industry
Coal gas generator, coal - to - natural gas, gas synthesis of ammonia/urea
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .
We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .