KGD - WQ - 510 Motor Vehicle Brake Emission Testing System

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Flow Control Range 100 - 2000 m³/h
Flow Control Stability ≤ ±5% of the set value
Flow Measurement Accuracy ≤ ±1.5% of the reading
Cooling Air Temperature 23°C ± 2°C
Cooling Air Humidity 50% ± 5%RH
Cooling Air Filtration Device Activated carbon filter and H13 - grade particle filter
Brand Name KACISE
Model Number KGD-WQ-510
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Flow Control Range 100 - 2000 m³/h Flow Control Stability ≤ ±5% of the set value
Flow Measurement Accuracy ≤ ±1.5% of the reading Cooling Air Temperature 23°C ± 2°C
Cooling Air Humidity 50% ± 5%RH Cooling Air Filtration Device Activated carbon filter and H13 - grade particle filter
Brand Name KACISE Model Number KGD-WQ-510
Certification CE Place of Origin CHINA
High Light Motor Vehicle Brake Emission Testing SystemKGD - WQ - 510 Brake Emission Testing System

KGD - WQ - 510 Motor Vehicle Brake Emission Testing System

Product Introduction

The KGD - WQ - 510 Motor Vehicle Brake Emission Testing System is a comprehensive solution specifically designed for the standardized testing of motor vehicle brake particle emissions. It is composed of an air duct control system, a particle sampling system, a particle number analysis system, an inertial brake dynamometer, and a main control system. The main test items include PM2.5, PM10, SPN, and TPN, which can meet the certification test requirements of the Euro 7 emission standard and related research and development test needs..

Product Features

  • The system is designed and optimized using advanced computational fluid dynamics simulation technology to reduce particle loss and improve the mixing degree at sampling points.
  • The inner wall of the dilution air duct is electropolished to reduce particle loss and improve the measurement repeatability.
  • The testing system and core components have been verified through years of practical applications, featuring excellent reliability in the testing installation and measurement process.
  • Advanced CPC (Condensation Particle Counter) technology is used for particle counting, ensuring first - class measurement accuracy and stability.

Technical Parameters

Parameter Details
Flow Control Range 100 - 2000 m³/h
Flow Control Stability ≤ ±5% of the set value
Flow Measurement Accuracy ≤ ±1.5% of the reading
Cooling Air Temperature 23°C ± 2°C
Cooling Air Humidity 50% ± 5%RH
Cooling Air Filtration Device Activated carbon filter and H13 - grade particle filter
Particle Sampling System
Maximum Particle Size Limit 2.5μm and 10μm
Filter Paper Sampling Temperature ≥ 15°C; No condensation
Filter Paper Diameter 47mm
Sampling Flow Rate 16.7 L/min
Sampling Flow Control Accuracy ≤ ±2% of the set value
Particle Number Analysis System
Measurement Principle Condensation Particle Counting (CPC)
Measurement Items TPM10; SPN10
Maximum Particle Size Limit 2.5μm
Minimum Particle Size Limit 10 nm (counting efficiency: 65% ± 15%)
15 nm (counting efficiency: >90%)
CPC Measurement Range 0 - 100000 #/cm³
CPC Measurement Precision ≤ ±10%
Primary Dilution Ratio 10
Secondary Dilution Ratio 10-30
VPR Removal Efficiency >99.9%
Response Time T90 < 5s

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement