China KGD-WQ-507 Dual - Channel Direct - Sampling Gas Emission Analyzer
China KGD-WQ-507 Dual - Channel Direct - Sampling Gas Emission Analyzer

  1. China KGD-WQ-507 Dual - Channel Direct - Sampling Gas Emission Analyzer

KGD-WQ-507 Dual - Channel Direct - Sampling Gas Emission Analyzer

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
CH₄ Detection Range 0 - 10 - 30000 ppmC
O₂ Detection Range 0 - 25%
NOₓ Detection Range 0 - 10 - 10000 ppmC
THC Detection Range 0 - 10 - 30000 ppmC
CO₂ Detection Range 0 - 0.1 - 20%
CO Detection Range 0 - 0.005 - 10%
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Brand Name KACISE
Model Number KGD-WQ-507
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

CH₄ Detection Range 0 - 10 - 30000 ppmC O₂ Detection Range 0 - 25%
NOₓ Detection Range 0 - 10 - 10000 ppmC THC Detection Range 0 - 10 - 30000 ppmC
CO₂ Detection Range 0 - 0.1 - 20% CO Detection Range 0 - 0.005 - 10%
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Brand Name KACISE Model Number KGD-WQ-507
Certification CE Place of Origin CHINA
High Light Direct sampling Gas Emission AnalyzerDual channel Gas Emission AnalyzerKGD-WQ-507 Gas Emission Analyzer
KGD-WQ-507 Dual-Channel Direct-Sampling Gas Emission Analyzer
Key Specifications
Attribute Value
THC Detection Range 0 - 10 - 30000 ppmC
CH₄ Detection Range 0 - 10 - 30000 ppmC
NOₓ Detection Range 0 - 10 - 10000 ppmC
CO Detection Range 0 - 0.005 - 10%
CO₂ Detection Range 0 - 0.1 - 20%
O₂ Detection Range 0 - 25%
Product Overview
The KGD-WQ-507 Dual-Channel Direct-Sampling Gas Emission Analyzer integrates multiple advanced detection technologies including Hydrogen Flame Ionization Detection (HFID), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Non-Dispersive Infrared (NDIR), and Magnetic-Parametric Detection (MPD). This comprehensive solution simultaneously measures volume concentrations of THC, CH₄, NOₓ, CO, CO₂, and O₂ in engine exhaust emissions, as well as CO₂ concentration in EGR pipeline gas.
KGD-WQ-507 Dual-Channel Gas Emission Analyzer in operation
Designed for engine manufacturers, testing institutions, and research facilities, this analyzer provides complete system testing solutions to meet increasingly stringent emission regulations.
Key Features
  • Simultaneous measurement of THC, NOₓ, CO, CO₂, O₂ with optional CH₄, NMHC, NH₃, N₂O measurement capabilities
  • NDUV technology for direct NO and NO₂ measurement without converter furnace, eliminating maintenance requirements
  • Optional CLD technology for NOₓ measurement
  • Real-time multi-point sampling and analysis of exhaust gas components
  • Comprehensive EGR gas path CO₂ concentration analysis
  • Integrated, automated design for ease of operation
  • High accuracy measurements with fast response times, comparable to imported equipment standards
Technical Parameters
Gas Type Detection Range Resolution Measurement Error Rise Time
THC 0 - 10 - 30000 ppmC 0.1ppm ≤ 2% of reading or ≤ 0.3% F.S. ≤ 1.5s
CH₄ 0 - 10 - 30000 ppmC 0.1ppm ≤ 2% of reading or ≤ 0.3% F.S. ≤ 1.5s
NOₓ 0 - 10 - 10000 ppmC 0.1ppm ≤ 2% of reading or ≤ 0.3% F.S. ≤ 1.5s
CO 0 - 0.005 - 10% 1ppm ≤ 2% of reading or ≤ 0.3% F.S. ≤ 1.5s
CO₂ 0 - 0.1 - 20% 0.01% ≤ 2% of reading or ≤ 0.3% F.S. ≤ 1.5s
O₂ 0 - 25% 0.01% ≤ 2% of reading or ≤ 0.3% F.S. ≤ 1.5s
EGR CO₂ 0 - 0.1 - 20% 0.01% ≤ 2% of reading or ≤ 0.3% F.S. ≤ 1.5s

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement